EMISSION CONTROL SYSTEM
Vacuum pump assembly Standard negative pressure Idling Higher than 87 kPa (650 mmHg, 25.6 in.Hg)

EGR VALVE
Tester Connection Condition Specified Condition
1 (VC) - 2 (E2) 20°C (68°F) 4.0 to 6.0 kΩ
3 (EGLS) - 2 (E2) 20°C (68°F)
EGR valve is fully opened
2.0 to 7.0 kΩ
20°C (68°F)
EGR valve is fully closed
0.1 to 2.5 kΩ

VACUUM REGULATING VALVE
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 11 to 13 Ω

VACUUM SWITCHING VALVE
Item Tester Connection Condition Specified Condition
Vacuum switching valve (for EGR Cut) 1 - 2 20°C (68°F) 37 to 44 Ω
Vacuum switching valve (for EGR Bypass Valve)