RM27T0E
_V1
General
_053654
SPECIFICATIONS
_0260374
SUSPENSION CONTROL
F
SPECIFICATIONS SUSPENSION CONTROL SERVICE DATA
Suspension Control System
| Height difference of left and right sides
|
20 mm (0.787 in.) or less
|
| Fluid temperature is 20°C (68°F)
|
2.6 to 3 MPa (26.6 to 30.5 kgf/cm2, 377 to 435 psi)
|
Height Control Compressor
| Tester Connection
|
Condition
|
Specified Condition
|
| 2 (L) - 1 (B)
|
15 to 25°C (59 to 77°F)
|
10 to 14 Ω
|
Control Valve Assembly
| Tester Connection
|
Condition
|
Specified Condition
|
| 1 (LH+) - 2 (E)
|
15 to 25°C (59 to 77°F)
|
10 to 14 Ω
|
| 3 (RH+) - 2 (E)
|
Height Control Sensor
| Tester Connection
|
Condition
|
Specified Condition
|
3 (SHG) - 2 (SHRR)
3 (SHG) - 2 (SHRL)
|
High (45°)
|
4.4 to 4.6 V
|
| Normal (0°)
|
2.3 to 2.6 V
|
| Low (-45°)
|
0.4 to 0.6 V
|
Front Acceleration Sensor
| Tester Connection
|
Condition
|
Specified Condition
|
| 1 (SGFR) - 2 (SGR)
|
Sensor stationary
|
Approx. 2.0 to 2.5 V
|
| Sensor tilted
|
Changes between approx. 0.9 and 2.3 V
|
Rear Acceleration Sensor
| Tester Connection
|
Condition
|
Specified Condition
|
| 1 (SGRR) - 2 (SGND)
|
Sensor stationary
|
Approx. 2.0 to 2.5 V
|
| Sensor tilted
|
Changes between approx. 0.9 and 2.3 V
|
Absorber Control Actuator
| Tester Connection
|
Condition
|
Specified Condition
|
| 1 (FAL+) - 2 (FAL-)
|
Always
|
6.4 to 7.2 V
|
| 3 (FBL+) - 4 (FBL-)
|
| 1 (FAR+) - 2 (FAR-)
|
| 3 (FBR+) - 4 (FBR-)
|