RM27T0E
_V1
General
_053654
SPECIFICATIONS
_0260392
1GD-FTV INTAKE / EXHAUST
F
SPECIFICATIONS 1GD-FTV INTAKE / EXHAUST SERVICE DATA
INTAKE SYSTEM
| Turbocharger pressure
|
Standard pressure (Gauge Pressure)
|
11.4 to 47.2 kPa (0.1 to 0.5 kgf/cm2, 1.7 to 6.8 psi)
|
INTAKE MANIFOLD
| Item
|
Tester Connection
|
Condition
|
Specified Condition
|
| Vacuum switching valve (for Swirl Control Valve)
|
1 - 2
|
20°C (68°F)
|
33 to 39 Ω
|
| 1 - Body ground
|
10 kΩ or higher
|
| 2 - Body ground
|
10 kΩ or higher
|
EXHAUST MANIFOLD W/ TURBOCHARGER
| Axial play of turbine shaft
|
Standard
|
0.11 mm (0.00433 in.)
|
| Turbocharger nozzle vane control actuator
|
1 - 2
|
Condition 20°C (68°F)
|
1 to 100 Ω
|
1 (M-) - Body ground
2 (M+) - Body ground
|
Always
|
10 MΩ or higher
|
EXHAUST PIPE
| Compression spring
|
Minimum length
|
38.5 mm (1.52 in.)
|