22204
1.INSPECT INTAKE MASS AIR FLOW METER SUB-ASSEMBLY
Check the output voltage.
Apply battery voltage across terminals 1 (+B) and 2 (E2G).
While using the battery during inspection, do not bring the positive (+) and negative (-) tester probes too close to each other as a short circuit may occur.
Using a voltmeter, connect the positive (+) tester probe to terminal 3 (VG) and the negative (-) tester probe to terminal 2 (E2G).
Blow air into the intake mass air flow meter sub-assembly and check that the voltage fluctuates.
| *a | Component without harness connected
(Intake Mass Air Flow Meter Sub-assembly) |
|
Air |
If the result is not as specified, replace the intake mass air flow meter sub-assembly.
Perform a visual check for any foreign matter on the platinum hot wire (heater) of the intake mass air flow meter sub-assembly shown in the illustration.
There is no foreign matter.
| *1 | Platinum Hot Wire (Heater) |
If the result is not as specified, replace the intake mass air flow meter sub-assembly.
Check the intake air temperature sensor.
| *a | Component without harness connected
(Intake Mass Air Flow Meter Sub-assembly) |
*b | Resistance |
| *c | Temperature | *d | Acceptable Range |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 4 (THA) - 5 (E2) | -20°C (-4°F) | 12.5 to 16.9 kΩ |
| 20°C (68°F) | 2.19 to 2.67 kΩ | |
| 60°C (140°F) | 0.50 to 0.68 kΩ |
If the result is not as specified, replace the intake mass air flow meter sub-assembly.