Home › Engine / Hybrid System › 1GR-FE (ENGINE CONTROL) › AIR FUEL RATIO SENSOR
RM27T0E _51 Engine / Hybrid System _053657 1GR-FE ENGINE CONTROL _0260432 AIR FUEL RATIO SENSOR G

1GR-FE ENGINE CONTROL  AIR FUEL RATIO SENSOR  INSPECTION  


PROCEDURE

Hide 89467B 1.INSPECT AIR FUEL RATIO SENSOR

a.
A226559E01
2.487,0.083 3.096,0.272 0.608,0.189 10 HA1A*A 0.565,0.256 0.860,0.455 0.295,0.199 10 +B 0.023,0 0.261,0.272 0.238,0.272 10 *a 2.487,0.385 3.096,0.573 0.608,0.189 10 HA2A*B 1.44,0.917 0.975,0.379 0.975,0.379 0.841,0.379 false 1.967,0.885 2.316,0.196 2.316,0.196 2.446,0.196 false 0.298,0.915 0.784,1.127 0.486,0.212 10 A1A-*A 0.298,1.207 0.784,1.421 0.486,0.214 10 A2A-*B 0.91,1.029 1.067,1.029 1.067,1.029 1.451,1.238 false

Measure the heater resistance according to the value(s) in the table below.

Standard Resistance (for Bank 1):
Tester Connection Condition Specified Condition
1 (HA1A) - 2 (+B) 20°C (68°F) 1.8 to 3.4 Ω
1 (HA1A) - 4 (A1A-) Always 10 kΩ or higher


Standard Resistance (for Bank 2):
Tester Connection Condition Specified Condition
1 (HA2A) - 2 (+B) 20°C (68°F) 1.8 to 3.4 Ω
1 (HA2A) - 4 (A2A-) Always 10 kΩ or higher


Text in Illustration
*A for Bank 1
*B for Bank 2
*a Component without harness connected
(Air Fuel Ratio Sensor)

If the result is not as specified, replace the air fuel ratio sensor.