Home › Engine / Hybrid System › 1GR-FE (ENGINE CONTROL) › HEATED OXYGEN SENSOR
RM27T0E _51 Engine / Hybrid System _053657 1GR-FE ENGINE CONTROL _0260433 HEATED OXYGEN SENSOR G

1GR-FE ENGINE CONTROL  HEATED OXYGEN SENSOR  INSPECTION  


PROCEDURE

Hide 89465 1.INSPECT HEATED OXYGEN SENSOR

a.
A224879E11
1.438,1.135 1.167,0.688 1.167,0.688 1.104,0.688 false 1.938,1.146 2.219,0.677 2.219,0.677 2.271,0.677 false 1.438,1.542 1.073,1.281 1.073,1.281 1,1.281 false 1.344,3.406 1.083,2.958 1.083,2.958 1.021,2.958 false 1.354,3.802 0.99,3.552 0.99,3.552 0.917,3.552 false 2.01,3.396 2.292,2.927 2.292,2.927 2.354,2.927 false 2.344,0.604 2.948,0.792 0.604,0.188 10 false HT1B 0.844,0.604 1.135,0.802 0.292,0.198 10 false +B 2.385,2.854 2.99,3.042 0.604,0.188 10 false HT2B 0.74,1.167 0.969,1.354 0.229,0.188 10 false E2 0.052,0.052 0.25,0.208 0.198,0.156 10 false *a 0.052,0.26 0.26,0.49 0.208,0.229 10 false *A 0.063,2.667 0.271,2.875 0.208,0.208 10 false *B 0.76,2.875 1.052,3.073 0.292,0.198 10 false +B 0.656,3.427 0.885,3.615 0.229,0.188 10 false E2

Measure the resistance according to the value(s) in the table below.

Standard Resistance (for Bank 1):
Tester Connection Condition Specified Condition
1 (HT1B) - 2 (+B) 20°C (68°F) 11 to 16 Ω
1 (HT1B) - 4 (E2) Always 10 kΩ or higher


Standard Resistance (for Bank 2):
Tester Connection Condition Specified Condition
1 (HT2B) - 2 (+B) 20°C (68°F) 11 to 16 Ω
1 (HT2B) - 4 (E2) Always 10 kΩ or higher


Text in Illustration
*A for Bank 1
*B for Bank 2
*a Component without harness connected
(Heated Oxygen Sensor)

If the result is not as specified, replace the heated oxygen sensor.