1KD-FTV ENGINE CONTROL  MANIFOLD ABSOLUTE PRESSURE SENSOR  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 89421C 1.INSPECT MANIFOLD ABSOLUTE PRESSURE SENSOR

a.

Inspect the power source voltage.

i.

Disconnect the manifold absolute pressure sensor connector.


ii.
A225145E03
1.719,0.375 1.635,0.375 1.635,0.375 1.188,1.302 true 0.552,0.604 0.646,0.604 0.646,0.604 0.938,1.313 true 1.771,0.313 2.24,0.531 0.469,0.219 10 true 3 (VC) 0.167,0.51 0.521,0.719 0.354,0.208 10 true 1 (E) 0.125,0.094 0.333,0.271 0.208,0.177 10 false *a

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
C83-3 (VC) - C83-1 (E) Ignition switch ON 4.75 to 5.25 V


Text in Illustration
*a Front view of wire harness connector
(to Manifold Absolute Pressure Sensor)

If the result is not as specified, inspect the wire harness or ECM (See page Engine / Hybrid System>1KD-FTV (ENGINE CONTROL)>ECD SYSTEM>TERMINALS OF ECM).


iii.

Connect the manifold absolute pressure sensor connector.



b.

Check the power supply.

i.

Turn the ignition switch ON.


ii.

Disconnect the vacuum hose from the manifold absolute pressure sensor.


iii.
U169309E02
1.938,0.99 1.365,1.833 1.365,1.833 1.365,1.917 false 2,1.135 2.531,1.833 2.531,1.833 2.531,1.917 false 0.188,0.156 0.385,0.323 0.198,0.167 10 false *a 1.063,1.948 1.573,2.115 0.51,0.167 10 false 5 (PIM) 2.146,1.938 2.813,2.104 0.667,0.167 10 false 16 (EPIM) 1.896,0.521 2.167,0.698 0.271,0.177 10 false C91

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
C91-5 (PIM) - C91-16 (EPIM) -13.3 kPa (100 mmHg, 3.94 in.Hg) 0.0 to 0.3 V
-26.6 kPa (199 mmHg, 7.85 in.Hg) 0.1 to 0.4 V
-40 kPa (300 mmHg, 11.81 in.Hg) 0.3 to 0.6 V


Text in Illustration
*a Component without harness connected
(ECM)
V100135

Vacuum

HINT:

The values in the "Condition" column are gauge pressures.


If the result is not as specified, replace the manifold absolute pressure sensor.


iv.
U169310E02
3,2.74 2.906,2.74 2.906,2.74 2.656,3.542 true 1.948,1 1.375,1.844 1.375,1.844 1.375,1.927 false 2.01,1.146 2.542,1.844 2.542,1.844 2.542,1.927 false 0.208,0.156 0.406,0.323 0.198,0.167 10 false *a 3.042,2.646 3.365,2.896 0.323,0.25 10 false SST 1.083,1.958 1.594,2.125 0.51,0.167 10 false 5 (PIM) 2.156,1.948 2.823,2.115 0.667,0.167 10 false 16 (EPIM) 1.906,0.531 2.177,0.708 0.271,0.177 10 false C91

Using SST, measure the voltage according to the value(s) in the table below.

SST
09992-00242  

Standard Voltage:
Tester Connection Condition Specified Condition
C91-5 (PIM) - C91-16 (EPIM) 19.6 kPa (0.20 kgf/cm2, 2.84 psi) 0.1 to 0.4 V
39.2 kPa (0.40 kgf/cm2, 5.69 psi) 0.3 to 0.6 V
58.8 kPa (0.60 kgf/cm2, 8.53 psi) 0.5 to 0.8 V
78.5 kPa (0.80 kgf/cm2, 11.4 psi) 0.7 to 1.1 V
98.0 kPa (1.00 kgf/cm2, 14.2 psi) 0.9 to 1.3 V


Text in Illustration
*a Component without harness connected
(ECM)
V100135

Pressure

HINT:

The values in the "Condition" column are gauge pressures.


If the result is not as specified, replace the manifold absolute pressure sensor.