Home › Engine / Hybrid System › 1KD-FTV (ENGINE CONTROL) › VACUUM SWITCHING VALVE › 2015.06–2020.08
RM27T0E _51 Engine / Hybrid System _053659 1KD-FTV ENGINE CONTROL _0260457 VACUUM SWITCHING VALVE G

1KD-FTV ENGINE CONTROL  VACUUM SWITCHING VALVE  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 17650E 1.INSPECT VACUUM SWITCHING VALVE (for Engine Mounting)

a.
A222590E01
0.948,0.688 0.729,0.271 0.729,0.271 0.646,0.271 true 1.052,0.729 1.479,0.76 1.479,0.76 1.521,0.76 true 0.531,0.188 0.646,0.354 0.115,0.167 10 false 2 0.083,0.052 0.302,0.219 0.219,0.167 10 false *a 1.531,0.667 1.646,0.833 0.115,0.167 10 false 1

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 37 to 44 Ω
1 - Body ground
2 - Body ground
20°C (68°F) 1 MΩ or higher


Text in Illustration
*a Component without harness connected
(Vacuum Switching Valve (for Engine Mounting))

If the result is not as specified, replace the vacuum switching valve.


b.
A222591E01
1.573,2.438 1.76,1.792 1.76,1.792 1.813,1.792 true 1.385,2.667 0.896,2.667 true 2.646,2.677 2.792,2.802 2.792,2.802 2.854,2.802 false 0.719,2.563 0.885,2.719 0.167,0.156 10 false *2 0.458,1.542 0.625,1.698 0.167,0.156 10 false *4 0.969,0.938 1.135,1.094 0.167,0.156 10 false *3 2.865,2.708 3.031,2.865 0.167,0.156 10 false *5 1.823,1.708 1.99,1.865 0.167,0.156 10 false *1

Check operation of the vacuum switching valve.

i.

When a vacuum of 67 kPa (500 mmHg, 19.7 in.Hg) is applied to port F, check that air flows from port E to the filter.

Text in Illustration
*1 Port E
*2 Port F
*3 Vacuum
*4 Air
*5 Filter


ii.
A222592E01
1.417,1.104 1.635,0.229 1.635,0.229 1.698,0.229 true 1.25,1.292 0.771,1.292 true 1.698,0.167 1.865,0.344 0.167,0.177 10 false *1 0.594,1.219 0.76,1.396 0.167,0.177 10 false *2 0.188,0.583 0.354,0.76 0.167,0.177 10 false *3

Apply battery voltage across terminals 1 and 2.

Text in Illustration
*1 Port E
*2 Port F
*3 Air


iii.

Check that air flows from port E to port F.

If the result is not as specified, replace the vacuum switching valve.