89463A
1.INSTALL NITROGEN OXIDES SENSOR
Install the No. 1 sensor bracket with the 2 nuts to the nitrogen oxides sensor, and attach the 2 clamps.
Using SST, install the nitrogen oxides sensor.
| *a | Torque Wrench Fulcrum Length |
Replace with a new part if it is dropped or if it receives a strong impact.
Calculate the torque wrench reading when changing the fulcrum length of the torque wrench (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).
When using SST (fulcrum length of 132 mm (5.20 in.)) + torque wrench (fulcrum length of 255 mm (10.0 in.)): 46 N*m (470 kgf*cm, 34 ft.*lbf)
Install the controller portion (No. 1 sensor bracket) with the 2 bolts, and then attach the connector and 3 clamps.
Complete the installation so that there is no tension or slack in the harness of the nitrogen oxides sensor, and there is no interference.
89439K
2.INSTALL NO. 3 SENSOR BRACKET
Install the No. 3 sensor bracket with the 2 bolts.