Home › Engine / Hybrid System › 1GD-FTV (ENGINE CONTROL) › RELAY (w/o Urea SCR System) › 2015.06–2017.08
RM27T0E _51 Engine / Hybrid System _053660 1GD-FTV ENGINE CONTROL _0260474 RELAY(w/o Urea SCR System) G

1GD-FTV ENGINE CONTROL  RELAY(w/o Urea SCR System)  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 82641 1.INSPECT NO. 1 INTEGRATION RELAY

A332403E01
1.519,2.251 1.851,2.425 0.332,0.174 10 1C 3.117,2.261 3.448,2.435 0.332,0.174 10 1B 5.029,2.25 5.361,2.425 0.332,0.174 10 1A 1.452,2.214 1.779,2.429 0.327,0.215 3.047,2.217 3.374,2.432 0.327,0.215 4.955,2.214 5.282,2.429 0.327,0.215

Text in Illustration
*a Component without harness connected
(No. 1 Integration Relay)
- -

NOTICE:
·

The IG2 relay, EFI relay and EFI MAIN relay are built into the No. 1 integration relay.

·

Before performing the relay inspections for the relays of the No. 1 integration relay, inspect the IG2, EFI-MAIN NO. 1 and EFI-MAIN NO. 2 fuses.



a.

Inspect the IG2 relay.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1C-1 - 1A-4 Battery voltage not applied to terminals 1A-1 and 1A-3 10 kΩ or higher
Battery voltage applied to terminals 1A-1 and 1A-3 Below 1 Ω


If the result is not as specified, replace the No. 1 integration relay.



b.

Inspect the EFI relay.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1C-1 - 1B-4 Battery voltage not applied to terminals 1B-2 and 1B-3 10 kΩ or higher
Battery voltage applied to terminals 1B-2 and 1B-3 Below 1 Ω


If the result is not as specified, replace the No. 1 integration relay.



c.

Inspect the EFI MAIN relay.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1C-1 - 1B-8 Battery voltage not applied to terminals 1B-5 and 1B-7 10 kΩ or higher
Battery voltage applied to terminals 1B-5 and 1B-7 Below 1 Ω


If the result is not as specified, replace the No. 1 integration relay.



Hide 2.INSPECT EDU RELAY (EDU)

a.
A167865E04
1.99,0.719 1.531,0.365 false 2.667,0.677 3.073,0.302 false 2.542,1.115 3.073,1.115 false 2.542,1.625 3.083,1.625 false 0.198,0.667 0.333,0.917 0.135,0.25 10 false 5 1.198,0.667 1.365,0.875 0.167,0.208 10 false 3 0.198,1.198 0.354,1.49 0.156,0.292 10 false 2 1.198,1.198 1.385,1.417 0.188,0.219 10 false 1 1.396,0.229 1.583,0.448 0.188,0.219 10 false 1 3.115,0.188 3.271,0.479 0.156,0.292 10 false 2 3.146,1.5 3.313,1.708 0.167,0.208 10 false 3 3.146,1.021 3.281,1.271 0.135,0.25 10 false 5 0.083,0.073 0.615,0.292 0.531,0.219 10 false *1

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
Battery voltage applied to terminals 1 and 2 Below 1 Ω


If the result is not as specified, replace the EDU relay.


Hide 28380J 3.INSPECT FUEL PUMP RELAY (FUEL PMP) (for Double Tank Type)

a.
A167865E04
1.99,0.719 1.531,0.365 false 2.667,0.677 3.073,0.302 false 2.542,1.115 3.073,1.115 false 2.542,1.625 3.083,1.625 false 0.198,0.667 0.333,0.917 0.135,0.25 10 false 5 1.198,0.667 1.365,0.875 0.167,0.208 10 false 3 0.198,1.198 0.354,1.49 0.156,0.292 10 false 2 1.198,1.198 1.385,1.417 0.188,0.219 10 false 1 1.396,0.229 1.583,0.448 0.188,0.219 10 false 1 3.115,0.188 3.271,0.479 0.156,0.292 10 false 2 3.146,1.5 3.313,1.708 0.167,0.208 10 false 3 3.146,1.021 3.281,1.271 0.135,0.25 10 false 5 0.083,0.073 0.615,0.292 0.531,0.219 10 false *1

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
Battery voltage applied to terminals 1 and 2 Below 1 Ω


If the result is not as specified, replace the fuel pump relay.