16603B
1.INSTALL TENSIONER PULLEY
Perform the following procedure when it is necessary to replace the tensioner pulley.
The tensioner pulley service kit consists of a bolt, dust seal and tensioner pulley.
Install the dust seal and bolt to the tensioner pulley as shown in the illustration.
| *1 | Bolt |
| *2 | Tensioner Pulley |
| *3 | Dust Seal |
|
Front |
The dust seal must be oriented correctly when installed, If the dust seal is installed incorrectly, the bearing may be damaged.
Do not touch the seal surface of the bearing.
Be sure to use the bolt from the service kit.
Tighten the bolt by hand until the flange of the bolt contacts the dust seal and the tensioner pulley is fixed in place.
Do not use any tools.
Tighten the bolt.
16361A
2.INSTALL FAN AND GENERATOR V BELT
Install the fan and generator V belt to all the pulleys except the tensioner pulley.
| *1 | Generator Assembly |
| *2 | Idler Pulley Sub-assembly |
| *3 | Vane Pump Assembly |
| *4 | Fan Pulley |
| *5 | Tensioner Pulley |
| *6 | Crankshaft Pulley |
| *7 | No. 1 Idler Pulley Sub-assembly |
| *8 | Cooler Compressor Assembly |
Use the hexagonal part indicated by the arrow in the illustration to move the tensioner pulley downward and install the fan and generator V belt to the tensioner pulley.
The backside of the fan and generator V belt should face the tensioner pulley.
Check that the fan and generator V belt is properly set on each pulley.
16361A
3.INSPECT FAN AND GENERATOR V BELT