84461B
1.INSPECT LEVEL WARNING SWITCH
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | On | Below 0.5 Ω |
| 1 - 2 | Off | 1 MΩ or higher |
If the result is not as specified, replace the level warning switch.