22100
1.INSPECT FUEL SUPPLY PUMP
Inspect the suction control valve.
| *1 | Suction Control Valve |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 1.9 to 2.3 Ω |
If the result is not specified, replace the suction control valve assembly.