Home › Engine / Hybrid System › 2TR-FE (EMISSION CONTROL) › AIR PUMP
RM27T0E _51 Engine / Hybrid System _053671 2TR-FE EMISSION CONTROL _0260593 AIR PUMP A

2TR-FE EMISSION CONTROL  AIR PUMP  INSTALLATION  


PROCEDURE

Hide 1.INSTALL AIR PUMP

a.
A226842E02
1.073,0.948 1.208,0.771 1.208,0.771 1.479,0.771 true 0.99,0.656 1.104,0.521 1.104,0.521 1.479,0.521 true 0.823,0.531 1.167,0.188 1.167,0.188 1.458,0.188 true 1.49,0.125 1.677,0.281 0.188,0.156 10 false *1 1.49,0.438 1.677,0.594 0.188,0.156 10 false *2 1.49,0.708 1.677,0.865 0.188,0.156 10 false *3

Attach the 3 fittings of the air pump insulator to install the air pump to the bracket.

Text in Illustration
*1 Insulator
*2 Air Pump
*3 Air Pump Bracket
V100135

Upper


b.

Attach the air pump connector clamp.


Hide 17610C 2.INSTALL AIR PUMP ASSEMBLY

a.

Install the air pump assembly with the 3 bolts.

Torque:
20 N*m (204 kgf*cm, 15 ft.*lbf)


b.

Connect the air pump connector and attach the wire harness clamp.


Hide 17341 3.CONNECT NO. 1 AIR INJECTION SYSTEM HOSE

a.
U147610E02
1.198,0.688 1.448,0.271 1.448,0.271 1.542,0.271 true 0.99,0.677 0.875,0.292 0.875,0.292 0.781,0.292 true 2.823,0.198 3.104,0.354 0.281,0.156 10 false 90° 2.49,0.125 2.667,0.271 0.177,0.146 10 false *b 2.01,0.729 2.188,0.896 0.177,0.167 10 false *a 0.625,0.198 0.802,0.365 0.177,0.167 10 true *1 1.552,0.188 1.729,0.354 0.177,0.167 10 true *2

Connect the No. 1 air injection system hose so that its paint mark aligns with the rib of the air pump as shown in the illustration.

Text in Illustration
*1 Rib
*2 Paint Mark
*a Front
*b Upper

HINT:
·

Make sure the paint mark of the No. 1 air injection system hose is facing upward.

·

Make sure the direction of the hose clamp is as shown in the illustration.




Hide 17613 4.INSTALL AIR PUMP COVER (w/ Heater)

a.
A273789E04
2.792,1.552 2.635,1.552 2.635,1.552 2.271,1.771 true 2.802,1.458 2.958,1.625 0.156,0.167 10 false *1

Install the air pump cover with the 3 claws.

Text in Illustration
*1 Inlet

HINT:

Make sure the inlet of the air pump cover is oriented correctly and completely attached when installing the air pump cover.