Home › Engine / Hybrid System › 2TR-FE (EMISSION CONTROL) › AIR PUMP
RM27T0E _51 Engine / Hybrid System _053671 2TR-FE EMISSION CONTROL _0260593 AIR PUMP G

2TR-FE EMISSION CONTROL  AIR PUMP  INSPECTION  


PROCEDURE

Hide 17610C 1.INSPECT AIR PUMP ASSEMBLY

a.

Check the heater resistance.

i.
A226958E06
2.448,0.552 2.323,0.552 2.323,0.552 2,0.781 true 2.458,1.656 2.354,1.656 2.354,1.656 2.021,1.5 true 0.083,0.031 0.271,0.208 0.188,0.177 10 false *a 2.49,0.479 2.906,0.646 0.417,0.167 10 false APH+ 2.49,1.573 2.948,1.74 0.458,0.167 10 false APHG

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 (APH+) - 3 (APHG) -20°C (-4°F) 3.6 to 17.6 Ω
-10°C (14°F) 3.4 to 16.5 Ω
0°C (32°F) 3.1 to 15.4 Ω
10°C (50°F) 2.8 to 14.3 Ω
20°C (68°F) 2.7 to 13.2 Ω


Text in Illustration
*a Component without harness connected
(Air pump)

If the result is not as specified, replace the air pump assembly.