25710
1.INSPECT AIR SWITCHING VALVE ASSEMBLY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 4.5 to 5.5 Ω |
| 1 - Body ground | Always | 1 MΩ or higher |
| 2 - Body ground |
When measuring the resistance make sure that the surface temperature of the air switching valve is 20°C.
If the result is not as specified, replace the air switching valve assembly.
Check the operation of the air switching valve.
Check that air does not flow from port A to port B.
| *a | Port A |
| *b | Port B |
|
Air |
Make sure the applied pressure is 30 kPa (0.3 kgf/cm2, 4.4 psi) or less.
If the result is not as specified, replace the air switching valve assembly.
Apply battery voltage across terminals 1 and 2.
| *a | Component without harness connected
(Air Switching Valve Assembly) |
| *a | Port A |
| *c | Port B |
|
Air |
Apply voltage for 2 minutes or less.
Check that air flows from port A to port B.
If the result is not as specified, replace the air switching valve assembly.