Home › Engine / Hybrid System › 1GR-FE (EMISSION CONTROL) › PURGE VALVE
RM27T0E _51 Engine / Hybrid System _053672 1GR-FE EMISSION CONTROL _0260608 PURGE VALVE G

1GR-FE EMISSION CONTROL  PURGE VALVE  INSPECTION  


PROCEDURE

Hide 25860 1.INSPECT PURGE VSV

a.
A211313C02
0.979,1.406 0.906,1.406 0.906,1.406 0.76,0.823 true 0.417,1.406 0.49,1.406 0.49,1.406 0.604,0.823 true 0.708,3.115 0.823,3.115 0.823,3.115 1.156,3.406 false 1.229,3.438 1.583,3.26 1.583,3.26 1.667,3.26 false 0.271,1.313 0.396,1.479 0.125,0.167 10 false 2 1.01,1.313 1.135,1.479 0.125,0.167 10 false 1 0.563,3.021 0.688,3.188 0.125,0.167 10 false 2 1.698,3.167 1.823,3.333 0.125,0.167 10 false 1

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 23 to 26 Ω
1 - Body ground Always 10 MΩ or higher
2 - Body ground Always 10 MΩ or higher


HINT:

When measuring the coil resistance make sure that the surface temperature of the purge VSV is 20°C.



b.

Check the operation of the purge VSV.

i.
A211314E03
0.853,0.667 1.026,0.841 0.173,0.173 10 *1 0.775,1.312 0.952,1.485 0.177,0.173 10 *2 1.201,1.793 1.395,1.956 0.194,0.163 10 *a 0.973,1.398 1.072,1.398 1.072,1.398 1.29,1.652 false 1.046,0.762 1.145,0.762 1.145,0.762 1.586,1.23 false

Check that air does not flow from port E to port F.

Text in Illustration
*1 Port E
*2 Port F
*a Does not flow
V100135

Air pressure


ii.
A211315E05
0.551,0.812 0.730,0.974 0.179,0.162 10 *1 0.291,1.265 0.470,1.427 0.179,0.162 10 *2 0.522,1.354 0.629,1.354 0.629,1.354 0.898,1.69 false 0.752,0.894 0.857,0.894 0.857,0.894 1.176,1.306 false

Apply battery voltage to the connector and check the VSV operation.

OK:
Measurement Condition Specified Condition
Battery positive (+) → terminal 1
Battery negative (-) → terminal 2
Air flows from port E to port F


Text in Illustration
*1 Port E
*2 Port F
V100135

Air pressure

If the result is not as specified, replace the purge VSV.