Home › Engine / Hybrid System › 1GD-FTV (EMISSION CONTROL) › UREA PUMP › 2015.06–2021.06
RM27T0E _51 Engine / Hybrid System _053675 1GD-FTV EMISSION CONTROL _0260631 UREA PUMP G

1GD-FTV EMISSION CONTROL  UREA PUMP  INSPECTION  


PROCEDURE

Hide 77871 1.INSPECT UREA PUMP

a.

Inspect the level sensor.

i.
A355507E02
1.292,2.542 0.479,2.542 false 1.292,3.417 0.479,3.417 false 2.104,0.729 2.323,0.208 2.323,0.208 2.427,0.208 false 2.063,0.948 1.792,1.573 1.792,1.573 1.667,1.573 false 0.177,0.073 0.427,0.271 0.25,0.198 10 false *a 2.469,0.125 2.865,0.302 0.396,0.177 10 false ELV1 1.344,1.49 1.625,1.667 0.281,0.177 10 false LV1 0.25,2.448 0.458,2.646 0.208,0.198 10 false *b 0.25,3.313 0.458,3.51 0.208,0.198 10 false *c

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
14(LV1) - 6(ELV1) Float position is upper 23.37 to 24.47 kΩ
Float position is lower 1.40 to 1.46 kΩ


Text in Illustration
*a Component without harness connected
(Urea Pump)
*b Upper
*c Lower



b.

Inspect the tank heater.

i.
A355506E01
0.131,0.086 0.346,0.249 0.215,0.163 10 *a 1.003,1.175 0.599,1.76 0.599,1.76 0.46,1.76 false 1.446,1.175 1.85,1.76 1.85,1.76 1.989,1.76 false 0.096,1.671 0.400,1.829 0.304,0.158 10 TH+ 1.999,1.671 2.304,1.829 0.304,0.158 10 TH-

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
9(TH+) - 11(TH-) 25°C (77°F) 1.39 to 1.54 Ω


Text in Illustration
*a Component without harness connected
(Urea Pump)



c.

Inspect the temperature sensor.

i.
A355506E02
0.131,0.113 0.346,0.276 0.215,0.163 10 *a 1.003,0.961 0.599,0.464 0.599,0.464 0.46,0.464 false 1.24,0.961 1.644,0.464 1.644,0.464 1.782,0.464 false 0.021,0.375 0.386,0.533 0.365,0.158 10 TUW 1.81,0.375 2.284,0.533 0.474,0.158 10 ETUW

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1(TUW) - 2(ETUW) 20°C (68°F) 2.47 to 2.56 kΩ
30°C (86°F) 1.69 to 1.75 kΩ


Text in Illustration
*a Component without harness connected
(Urea Pump)



d.

Inspect the pump motor.

i.
A355506E04
2.188,0.969 1.979,0.469 1.979,0.469 1.833,0.469 false 2.531,0.969 2.76,0.469 2.76,0.469 2.896,0.469 false 2.188,1.177 1.979,1.688 1.979,1.688 1.833,1.688 false 2.531,1.177 2.76,1.688 2.76,1.688 2.896,1.688 false 0.135,0.083 0.354,0.25 0.219,0.167 10 false *a 1.333,0.375 1.75,0.531 0.417,0.156 10 false PHAA 2.938,0.375 3.354,0.531 0.417,0.156 10 false PHAB 1.26,1.604 1.74,1.76 0.479,0.156 10 false MGND 2.927,1.604 3.344,1.76 0.417,0.156 10 false PHAC

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
7(PHAA) - 8(PHAB) 20 to 30 °C (68 to 86°F) 0.35 to 0.43 Ω
7(PHAA) - 16(PHAC)
8(PHAB) - 16(PHAC)
7(PHAA) - 15(MGND) Always 10 kΩ or higher
8(PHAB) - 15(MGND)
16(PHAC) - 15(MGND)


Text in Illustration
*a Component without harness connected
(Urea Pump)

If the result is not as specified, replace the urea pump.