Home › Engine / Hybrid System › 1GD-FTV (EMISSION CONTROL) › UREA PUMP CONTROL ECU › 2015.06–2021.06
RM27T0E _51 Engine / Hybrid System _053675 1GD-FTV EMISSION CONTROL _0260633 UREA PUMP CONTROL ECU A

1GD-FTV EMISSION CONTROL  UREA PUMP CONTROL ECU  REMOVAL  


PROCEDURE

Hide 89678A 1.REMOVE NO. 2 UREA PUMP CONTROL BRACKET

a.
A352192

Remove the 3 bolts and No. 2 urea pump control bracket from the frame LH.


Hide 89677B 2.REMOVE NO. 3 UREA PUMP CONTROL BRACKET

a.
A352193

Remove the bolt and No. 3 urea pump control bracket from the No. 4 urea pump control bracket.


Hide 896B1 3.REMOVE UREA PUMP CONTROL ECU

a.
A352194

Raise the lever while pushing the lock on the lever and disconnect the connector from the urea pump control ECU.

NOTICE:

After disconnecting a connector, make sure that dirt, water and other foreign matter does not contact the connector.



b.
A352181

Detach the 3 clamps and disconnect wire harness from the No. 4 urea pump control bracket and No. 1 urea pump control bracket.


c.
A356574

Remove the 3 bolts and No. 4 urea pump control bracket from the urea pump control ECU.


d.
A352195

Remove the 3 bolts and No. 1 urea pump control bracket from the frame LH.


e.
A356575

Remove the 3 bolts and urea pump control ECU from the No. 1 urea pump control bracket.