89465
1.INSTALL HEATED OXYGEN SENSOR (for Bank 1 Sensor 2)
89465
2.INSTALL HEATED OXYGEN SENSOR (for Bank 2 Sensor 2)
17450B
3.INSTALL FRONT NO. 2 EXHAUST PIPE ASSEMBLY
Install a new gasket and the No. 2 front exhaust pipe to the exhaust manifold with 2 new nuts.
Connect the heated oxygen sensor connector.
17548
4.INSTALL EXHAUST PIPE STOPPER BRACKET
Install the stopper bracket with the 2 bolts.
17410
5.INSTALL FRONT EXHAUST PIPE ASSEMBLY
Using a vernier caliper, measure the free length of the compression spring.
43 mm (1.693 in.)
If the free length is less than the minimum, replace the compression spring.
Using a plastic-faced hammer and wooden block, tap in a new gasket until its surface is flush with the front exhaust pipe.
| *1 | Gasket |
| *2 | Wooden Block |
Be sure to install the gasket so that it faces the correct direction.
Do not reuse the gasket.
Do not damage the gasket.
When connecting the exhaust pipe, do not push in the gasket with the exhaust pipe.
Install a new gasket and the front exhaust pipe to the exhaust manifold with 2 new nuts.
Connect the front exhaust pipe to the front No. 2 exhaust pipe with the 2 bolts.
Connect the heated oxygen sensor connector.
17420
6.INSTALL CENTER EXHAUST PIPE ASSEMBLY
Connect the center exhaust pipe to the 3 exhaust pipe supports.
Install the center exhaust pipe with the 2 compression springs and 4 bolts.
17430
7.INSTALL TAILPIPE ASSEMBLY
Install the tailpipe to the exhaust pipe support.
Install a new gasket to the center exhaust pipe.
Install the 2 bolts.
8.INSPECT FOR EXHAUST GAS LEAK
If gas is leaking, tighten the areas necessary to stop the leak. Replace damaged parts as necessary.
for Automatic Transmission:
If an exhaust gas leak has been repaired, perform an inspection following the repair (See page Engine / Hybrid System>1GR-FE (ENGINE CONTROL)>SFI SYSTEM>INITIALIZATION).