1.INSPECT THERMOSTAT
The valve opening temperature is inscribed on the thermostat.
Immerse the thermostat in water, and then gradually heat the water.
Check the valve opening temperature of the thermostat.
80 to 84°C (176 to 183°F)
If the valve opening temperature is not as specified, replace the thermostat.
Check the valve lift.
8.0 to 10 mm (0.315 to 0.394 in.) at 95°C (203°F)
| *a | Valve Lift |
If the valve lift is not as specified, replace the thermostat.
Check that the valve is fully closed when the thermostat temperature is below 77°C (171°F).