Home › Engine / Hybrid System › 5L-E (COOLING) › THERMOSTAT
RM27T0E _51 Engine / Hybrid System _053683 5L-E COOLING _0260669 THERMOSTAT G

5L-E COOLING  THERMOSTAT  INSPECTION  


PROCEDURE

Hide 16331A 1.INSPECT THERMOSTAT

P013560

HINT:

The valve opening temperature is inscribed on the thermostat.


a.

Immerse the thermostat in water, and then gradually heat the water.


b.

Check the valve opening temperature of the thermostat.

Standard valve opening temperature:

80 to 84°C (176 to 183°F)


If the valve opening temperature is not as specified, replace the thermostat.


c.
A224963E02
2.692,1.469 2.867,1.637 0.175,0.168 10 *a 2.69,1.558 2.546,1.558 2.546,1.558 2.239,1.676 false

Check the valve lift.

Standard valve lift:

8.0 to 10 mm (0.315 to 0.394 in.) at 95°C (203°F)


Text in Illustration
*a Valve Lift

If the valve lift is not as specified, replace the thermostat.


d.

Check that the valve is fully closed when the thermostat temperature is below 77°C (171°F).

If the valve is not fully closed, replace the thermostat.