Home › Engine / Hybrid System › 1GD-FTV (COOLING) › RADIATOR
RM27T0E _51 Engine / Hybrid System _053685 1GD-FTV COOLING _0260680 RADIATOR G

1GD-FTV COOLING  RADIATOR  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 16401A 1.CHECK RADIATOR RESERVOIR CAP SUB-ASSEMBLY

a.
A301812E02
2.26,1.698 2.49,1.698 false 1.021,1.458 1.396,1.458 true 2.5,1.594 2.875,1.813 0.375,0.219 10 false *a 0.854,1.375 1.229,1.594 0.375,0.219 10 false *b

Measure the valve opening pressure.

Text in Illustration
*a O-Ring
*b Rubber Packing

i.

If there are water stains or foreign matter on O-ring, clean it with water and finger scouring.


ii.

Check that O-ring is not deformed, cracked or swollen.


iii.

Apply engine coolant to O-ring and rubber packing before using a radiator cap tester.


iv.
A110393E22
0.375,1.146 0.542,0.344 0.542,0.344 0.615,0.344 false 1.552,1.063 1.688,0.438 1.688,0.438 1.771,0.438 false 0.719,2.135 1.021,2.365 0.302,0.229 10 false *a 1.813,0.344 2.115,0.573 0.302,0.229 10 false *b 0.635,0.24 0.938,0.469 0.302,0.229 10 false *1

When using the cap tester, tilt it 30° or more.

Text in Illustration
*1 Radiator Reservoir Cap Sub-assembly
*b Radiator Cap Tester
*a 30° or more


v.

Pump the cap tester several times, and then check the maximum pressure*.

Pump speed:

1 pump per second


*: Even if the cap cannot maintain the maximum pressure, it is not a defect.

Judgment Criterion:
Item Specified Condition
Standard value
(for brand-new cap)
93 to 123 kPa (1.0 to 1.3 kgf/cm2, 13.5 to 18 psi)
Minimum standard value
(after using cap)
79 kPa (0.8 kgf/cm2, 11.4 psi)


If the maximum pressure is less than the minimum standard value, replace the radiator reservoir cap sub-assembly.



Hide 16400 2.INSPECT FINS FOR BLOCKAGE

a.

If the fins are clogged, wash them with water or a steam cleaner and dry them with compressed air.

NOTICE:
·

To avoid damaging the fins, the injection direction should be at right angles to the core surface.

·

If the steam cleaner is too close to the core, there is a possibility of damaging the fins, so maintain the following injection distances.

Standard Injection Distance:
Injection Pressure Specified Condition
2942 to 4903 kPa
(30.0 to 50.0 kgf/cm2, 427 to 711 psi)
300 mm (11.8 in.)
4903 to 7845 kPa
(50.0 to 80.0 kgf/cm2, 711 to 1138 psi)
500 mm (19.7 in.)


·

If the fins are bent, straighten them with a screwdriver or pliers.

·

Do not expose electronic components to water.




b.

Dry the fins with compressed air.