1.INSPECT TRANSMISSION CONTROL SWITCH
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 (IG) - 7 (S) | Shift lever in S, "+" or "-" | Below 1 Ω |
| 3 (IG) - 7 (S) | Shift lever not in S, "+" or "-" | 10 kΩ or higher |
| *a | Component without harness connected
(Transmission Control Switch) |
If the result is not as specified, replace the transmission floor shift assembly.