28800
1.DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to disable the SRS system.
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).
When disconnecting the cable, some systems need to be initialized after the cable is reconnected (See page General>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION).
2.REMOVE INSTRUMENT PANEL SAFETY PAD SUB-ASSEMBLY
86652A
3.REMOVE SKID CONTROL BUZZER ASSEMBLY
Detach the clamp and remove the buzzer.
| *A | for LHD |
| *B | for RHD |
Disconnect the connector.