1. OPERATION CHECK
Disconnect the vacuum hose from the vacuum pump.
Connect the hose of a vacuum gauge to the pump.
| *1 | Vacuum Gauge |
| *2 | Plug |
Insert a plug into the other hose of the gauge.
Start the engine and warm it up for more than 2 minutes.
With the engine idling, measure the negative pressure of the pump.
More than 86.7 kPa (650 mmHg, 26 in.Hg)
Remove the gauge from the pump.
Connect the hose to the pump with the clip.