Hide 29331A 1.INSPECT VACUUM PUMP VANE

a.
C169339E06
2.708,0.656 2.708,0.333 2.708,0.333 2.323,0.333 false 1.323,1.365 1.323,1.458 1.323,1.458 1.677,1.458 false 0.531,1.531 0.531,1.708 0.531,1.708 0.76,1.708 false 1.708,1.375 1.885,1.521 0.177,0.146 10 false *2 0.781,1.625 0.948,1.771 0.167,0.146 10 false *1 2.135,0.25 2.292,0.396 0.156,0.146 10 false *1

Check that the vacuum pump vane or vacuum pump vane caps are not damaged or excessively worn out.

HINT:

If the vacuum pump vane or vacuum pump vane caps are damaged or excessively worn out, replace the damaged parts with new ones.


Text in Illustration
*1 Vacuum Pump Vane Cap
*2 Vacuum Pump Vane


b.
C169340E02
2.354,2.365 2.521,2.583 0.167,0.219 10 false A 1.271,2.365 1.438,2.583 0.167,0.219 10 false A 0.625,3 1.125,3.177 0.5,0.177 10 false 10mm 2.406,2.99 2.885,3.198 0.479,0.208 10 false 10mm

Using a micrometer, measure length A of the vacuum pump with the vacuum pump vane caps removed.

Text in Illustration
*a 10 mm (0.394 in.)

Minimum length A:

23.8 mm (0.937 in.)


NOTICE:

Measure the 10 mm (0.394 in.) in from each end of the vacuum pump vane.


HINT:

If the length is not as specified, replace the vacuum pump vane and vacuum pump vane caps with new ones.



c.
C169342E04
1.146,1.958 1.146,1.635 1.146,1.635 1.625,1.635 false 0.51,2.615 0.51,3.146 0.51,3.146 0.813,3.146 false 2.458,2.615 2.458,2.813 2.458,2.813 0.51,2.813 false 1.656,1.542 1.813,1.698 0.156,0.156 10 false *1 0.844,3.052 1.021,3.198 0.177,0.146 10 false *2 1.427,1.958 1.573,2.104 0.146,0.146 10 false B 1.438,2.281 1.583,2.427 0.146,0.146 10 false B 2.688,1.958 2.885,2.167 0.198,0.208 10 false *a 2.677,2.469 2.875,2.677 0.198,0.208 10 false *a

Using a vernier caliper, measure length B of the vacuum pump vane with the vacuum pump vane caps installed.

Text in Illustration
*1 Vacuum Pump Vane
*2 Vacuum Pump Vane Cap
*a 5 mm (0.197 in.)

Minimum length B:

85.0 mm (3.35 in.)


NOTICE:

Measure the length 5 mm (0.197 in.) in from each end of the vacuum pump vane caps.


HINT:

If the length is not as specified, replace the vacuum pump vane and vacuum pump vane caps with new ones.



Hide 2.INSPECT VACUUM PUMP HOUSING

a.
C334228

Check that the rotor part, coupling, vacuum pump housing or vacuum end cover is not damaged or excessively worn out.

NOTICE:

If the rotor part, coupling, vacuum pump housing or vacuum end cover is damaged or excessively worn out, replace the vacuum pump assembly.