Home › Steering › POWER ASSIST SYSTEMS › VANE PUMP(for 5L-E)
RM27T0E _55 Steering _053717 POWER ASSIST SYSTEMS _0260947 VANE PUMP(for 5L-E) G

POWER ASSIST SYSTEMS  VANE PUMP(for 5L-E)  INSPECTION  


PROCEDURE

Hide 44320 1.INSPECT VANE PUMP SHAFT AND BUSH IN VANE PUMP HOUSING

a.
U169879E02
3.021,1 3.302,1.302 0.281,0.302 10 false *a 1.469,0.208 1.813,0.51 0.344,0.302 10 false *b

Using a micrometer, measure the outer diameter of the vane pump shaft.

Text in Illustration
*a Outer Diameter
*b Inner Diameter


b.

Using a vernier caliper, measure the inner diameter of the vane pump front housing bush.


c.

Calculate the oil clearance.

Oil clearance = Inner diameter of the bush - Outer diameter of the shaft

Maximum oil clearance:

0.07 mm (0.00276 in.)


If the oil clearance is more than the maximum, replace the vane pump assembly.


Hide 2.INSPECT VANE PUMP ROTOR AND VANE PUMP PLATE

a.
C101977E14
2.448,0.344 3.146,0.583 0.698,0.24 10 false *a

Using a micrometer, measure the thickness of the vane pump plates.

Standard thickness:

1.397 to 1.403 mm (0.0550 to 0.0552 in.)


Text in Illustration
*a Thickness


b.
C101978E02
0.905,0.046 1.800,0.220 0.895,0.174 10 *1 1.133,0.13 1.414,0.13 1.414,0.13 1.524,0.239 false

Using a feeler gauge, measure the clearance between side of the vane pump rotor groove and the vane pump plates.

Maximum clearance:

0.033 mm (0.0013 in.)


Text in Illustration
*1 Feeler Gauge

If the clearance is more than the maximum, replace the vane pump.


Hide 3.INSPECT FLOW CONTROL VALVE

a.

Coat the flow control valve with power steering fluid and check that it falls smoothly into the flow control valve hole under its own weight.

If the value does not fall smoothly into the hole, replace the vane pump.


b.
R007591E16
2,0.229 2.313,0.427 0.313,0.198 10 false *a

Check the flow control valve for leakage. Close one of the holes and apply compressed air at 392 to 490 kPa (4 to 5 kgf/cm2, 57 to 71 psi) into the hole on the opposite side and confirm that air does not come out from the end holes.

Text in Illustration
*a Compressed Air

If air leaks, replace the vane pump assembly.


Hide 4.INSPECT FLOW CONTROL VALVE COMPRESSION SPRING

a.
R008702

Using a vernier caliper, measure the free length of the flow control valve compression spring.

Minimum free length:

32.3 mm (1.28 in.)


If the length is less than the minimum, replace the vane pump assembly.


Hide 5.INSPECT PRESSURE PORT UNION

a.

If the union seat in the pressure port union is severely damaged, it may cause fluid leakage. If the union seat is damaged, replace the vane pump assembly.