Home › Steering › STEERING COLUMN › HEATED STEERING WHEEL SYSTEM
RM27T0E _55 Steering _053718 STEERING COLUMN _0260963 HEATED STEERING WHEEL SYSTEM U

STEERING COLUMN  HEATED STEERING WHEEL SYSTEM  FAIL-SAFE CHART  


MALFUNCTION DETECTION


a.

Operation when malfunction is detected

Content Operation
When thermistor trouble is detected Heater turns off
When overheating (175°C (347°F)) of controller is detected Heater turns off
When load short current (50 A or more) is detected Heater turns off
When undervoltage (4.5 V) is detected Heater turns off
OFF timer (30 min.) After preset time of timer passes, heater off
Reverse voltage protection Protection circuit operates


b.

Malfunction detection conditions

i.

An open or short in the steering wheel thermistor continues for 2 seconds or more.


ii.

The steering heater switch is pressed continuously for 10 seconds or more.



c.

Malfunction display

i.

The LED of the steering heater switch turns off.



d.

Restore condition

i.

If the system returns to normal for 2 seconds or more, the previous operation before the malfunction occurred continues. However, regardless of if a malfunction is detected and the malfunction operation is occurring, or if the system returns to normal, the timer will turn off the heater 30 minutes after the switch was first turned on.