Home › Power Source / Network › 5L-E (BATTERY / CHARGING) › GENERATOR
RM27T0E _57 Power Source / Network _053723 5L-E BATTERY / CHARGING _0261017 GENERATOR G

5L-E BATTERY / CHARGING  GENERATOR  INSPECTION  


PROCEDURE

Hide 27330 1.INSPECT GENERATOR ROTOR ASSEMBLY

a.

Check the generator rotor for an open circuit.

i.
A220276E01
2.931,1.526 3.110,1.696 0.180,0.170 10 *1 2.114,1.756 2.806,1.612 2.806,1.612 2.919,1.612 false

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Slip ring - Slip ring 20°C (68°F) 2.1 to 2.5 Ω


Text in Illustration
*1 Slip Ring

If the result is not as specified, replace the generator rotor assembly.



b.

Check if the generator rotor is grounded.

i.
A220277E01
2.54,0.735 2.705,0.900 0.165,0.165 10 *1 1.974,0.408 2.162,0.574 0.188,0.165 10 *2 1.39,1.229 1.776,0.501 1.776,0.501 1.958,0.501 false 1.958,1.554 2.345,0.826 2.345,0.826 2.528,0.826 false

Measure the resistance according to the value(s) in the table below.

Standard Condition:
Tester Connection Condition Specified Condition
Slip ring - Rotor core Always 10 kΩ or higher


Text in Illustration
*1 Slip Ring
*2 Rotor Core

If the result is not as specified, replace the generator rotor assembly.



c.

Check that the slip rings are not rough or scored.

If they are rough or scored, replace the generator rotor assembly.


d.
A220278E01
0.521,0.531 0.701,0.687 0.180,0.156 10 *1

Using a vernier caliper, measure the slip ring diameter.

Standard diameter:

14.2 to 14.4 mm (0.559 to 0.567 in.)


Minimum diameter:

14.0 mm (0.551 in.)


Text in Illustration
*1 Diameter

If the diameter is less than the minimum, replace the generator rotor assembly.


e.

Inspect the bearing.

i.

Check that the bearing is not rough or worn.

If necessary, replace the generator rotor assembly.



Hide 27310 2.INSPECT DRIVE END FRAME

a.

Check the stator for an open circuit.

i.
A220279E02
2.479,0.385 2.542,0.156 2.542,0.156 2.906,0.156 false 2.604,1.031 2.802,0.167 true 2.938,0.073 3.115,0.24 0.177,0.167 10 false *1

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Coil lead - Coil lead Always Below 1 Ω


Text in Illustration
*1 Coil Lead

If the result is not as specified, replace the generator assembly.



b.

Check the stator for a short circuit.

i.
A220280E01
2.782,0.193 2.949,0.345 0.167,0.151 10 *1 0.785,1.256 0.953,1.407 0.167,0.151 10 *2 2.509,0.429 2.696,0.279 2.696,0.279 2.77,0.279 false 1.316,1.568 1.052,1.342 1.052,1.342 0.971,1.342 false

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Coil lead - Drive end frame Always 10 kΩ or higher


Text in Illustration
*1 Coil Lead
*2 Drive End Frame

If the result is not as specified, replace the generator assembly.



c.

Inspect the bearing.

i.

Check that the bearing is not rough or worn.

If necessary, replace the generator assembly.



Hide 27370 3.INSPECT BRUSH HOLDER

a.
P013535E05
0.927,0.813 1.458,1.052 0.531,0.24 10 true *1

Using a vernier caliper, measure the exposed brush length.

Standard exposed length:

9.5 to 11.5 mm (0.374 to 0.453 in.)


Minimum exposed length:

4.5 mm (0.177 in.)


Text in Illustration
*1 Length

If the exposed length is less than the minimum, replace the brush holder.


Hide 27357 4.INSPECT GENERATOR HOLDER WITH RECTIFIER

a.
A220282E01
0.736,0.593 0.906,0.749 0.170,0.156 10 *1 2.762,0.76 2.949,0.915 0.187,0.156 10 *2 1.872,0.972 1.092,0.677 1.092,0.677 0.941,0.677 false 2.207,1.138 2.61,0.846 2.61,0.846 2.745,0.846 false

Check the positive terminal of the rectifier.

Text in Illustration
*1 Positive (+) Terminal
*2 Rectifier Terminal

i.

Using an ohmmeter, connect one tester probe to the positive (+) terminal and the other to each rectifier terminal.


ii.

Reverse the polarity of the tester probes and repeat the step above.


iii.

Check that one polarity shows a resistance of below 1 Ω and the other shows a resistance of 10 kΩ or higher.

If the result is not as specified, replace the generator holder with rectifier.



b.
A220283E01
1.888,0.671 2.067,0.836 0.179,0.165 10 *1 1.584,1.389 1.767,0.749 1.767,0.749 1.881,0.749 false

Check the negative terminal of the rectifier.

Text in Illustration
*1 Negative (-) Terminal

i.

Using an ohmmeter, connect one tester probe to the negative (-) terminal and the other to each rectifier terminal.


ii.

Reverse the polarity of the tester probes and repeat the step above.


iii.

Check that one polarity shows a resistance of below 1 Ω and the other shows a resistance of 10 kΩ or higher.

If the result is not as specified, replace the generator holder with rectifier.



Hide 27700A 5.INSPECT GENERATOR REGULATOR ASSEMBLY

a.
A220284E01
0.663,1.216 0.840,1.382 0.177,0.166 10 *1 2.687,1.577 2.864,1.743 0.177,0.166 10 *2 1.702,1.005 1.02,1.304 1.02,1.304 0.861,1.304 false 2.242,1.308 2.56,1.667 2.56,1.667 2.679,1.667 false

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Terminal F - Terminal B Always Below 1 Ω or higher than 10 kΩ


Text in Illustration
*1 Terminal F
*2 Terminal B

If the result is not as specified, replace the generator regulator assembly.

HINT:

When the ohmmeter leads are initially touched to the regulator, one of the above values is output. When the leads are reversed, the reading changes to the other value.



b.
A220285E01
0.96,1.405 1.130,1.575 0.170,0.170 10 *2 2.097,1.41 2.266,1.580 0.170,0.170 10 *1 0.719,1.057 0.848,1.5 0.848,1.5 0.958,1.5 false 1.839,1.016 1.982,1.517 1.982,1.517 2.092,1.517 false

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Terminal F - Terminal E Always Below 1 Ω or higher than 10 kΩ


Text in Illustration
*1 Terminal F
*2 Terminal E

If the result is not as specified, replace the generator regulator assembly.

HINT:

When the ohmmeter leads are initially touched to the regulator, one of the above values is output. When the leads are reversed, the reading changes to the other value.