29300
1.INSPECT GENERATOR WITH VACUUM PUMP ASSEMBLY
Mount the generator in a vise between aluminum plates.
Insert a screwdriver to hold the generator rotor.
Install a bolt and nut to the outside of the pulley so that the bolt head and nut clamp the pulley, and then position a dial indicator as shown in the illustration.
Turn the pulley and measure the backlash between the generator rotor and vacuum pump shaft.
1.6 mm (0.0630 in.)
If the backlash is more than the maximum, replace the generator rotor and vacuum pump shaft.
29300
2.REMOVE VACUUM PUMP ASSEMBLY
Place matchmarks as shown in the illustration.
| *a | Matchmark |
Remove the 4 bolts and vacuum pump.
27039
3.REMOVE GENERATOR REAR END COVER
Remove the nut and terminal insulator.
Remove the bolt, 3 nuts, rectifier plate and rear end cover.
27370
4.REMOVE GENERATOR BRUSH HOLDER ASSEMBLY
Remove the brush holder cover.
Remove the 2 screws and brush holder.
Remove the plate seal.
27700A
5.REMOVE GENERATOR REGULATOR ASSEMBLY
Remove the 3 screws and generator regulator.
27357
6.REMOVE GENERATOR HOLDER WITH RECTIFIER
Remove the 4 screws and generator holder with rectifier.
Remove the 4 rubber insulators.
27359
7.REMOVE GENERATOR RECTIFIER END FRAME
Remove the 4 nuts and cord clip.
| *1 | Cord Clip |
Using SST, remove the rectifier end frame.
| *a | Hold |
|
Turn |
Remove the washer from the rotor.
27330
8.REMOVE GENERATOR ROTOR ASSEMBLY
Using SST and a press, press out the rotor.