Home › Power Source / Network › NETWORKING › CAN COMMUNICATION SYSTEM(for RHD with Entry and Start System) › 2015.06–2017.08
RM27T0E _57 Power Source / Network _053729 NETWORKING _0261033 CAN COMMUNICATION SYSTEM(for RHD with Entry and Start System) J

NETWORKING  CAN COMMUNICATION SYSTEM(for RHD with Entry and Start System)  Combination Meter ECU Communication Stop Mode  


DESCRIPTION

Detection Item Symptom Trouble Area
Combination Meter ECU Communication Stop Mode Either condition is met:
·

"Combination Meter" is not displayed on "Bus Check".

·

"Combination Meter ECU Communication Stop Mode" in "DTC Combination Table" applies.


·

Power source or inside combination meter assembly

·

Combination meter assembly



WIRING DIAGRAM

C175530E18
1.25,0.402 2.033,0.581 0.783,0.179 10 from Battery 1.091,1.109 2.050,1.318 0.959,0.210 10 from IG2 Relay 3.964,2.21 4.281,2.419 0.318,0.208 10 G6 3.964,2.376 5.842,2.561 1.878,0.186 10 Combination Meter Assembly 4.25,0.345 4.426,0.487 0.176,0.142 10 26 4.25,1.043 4.426,1.185 0.176,0.142 10 28 4.25,1.712 4.426,1.854 0.176,0.142 10 21 4.514,1.789 4.722,1.937 0.208,0.148 10 E2 4.514,1.128 4.774,1.276 0.260,0.148 10 IG+ 4.514,0.412 4.627,0.560 0.113,0.148 10 B 2.996,0.288 3.490,0.439 0.494,0.152 10 ECU-B 3.004,0.97 3.585,1.122 0.581,0.152 10 GAUGE

CAUTION / NOTICE / HINT

NOTICE:

Inspect the fuses for circuits related to this system before performing the following inspection procedure.


PROCEDURE

1.CHECK HARNESS AND CONNECTOR (COMBINATION METER - BATTERY AND BODY GROUND)
a.
U169933E02
1.438,1.385 1.875,0.542 1.875,0.542 1.969,0.542 true 1.167,1.396 1.604,0.271 1.604,0.271 1.698,0.271 true 0.531,1.417 0.74,1.885 0.74,1.885 0.844,1.885 true 0.24,0.573 0.573,0.76 0.333,0.188 10 false G6 1.74,0.208 1.885,0.396 0.146,0.188 10 false B 2.01,0.479 2.271,0.667 0.26,0.188 10 false IG+ 0.083,0 0.417,0.188 0.333,0.188 10 false *a 0.896,1.802 1.135,1.99 0.24,0.188 10 false E2

Disconnect the G6 combination meter assembly connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
G6-21 (E2) - Body ground Always Below 1 Ω



c.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
G6-26 (B) - Body ground Always 11 to 14 V
G6-28 (IG+) - Body ground Engine switch on (IG) 11 to 14 V



Text in Illustration
*a Front view of wire harness connector
(to Combination Meter Assembly)


OK

REPLACE COMBINATION METER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR