Home › Vehicle Interior › SEAT › POWER SEAT SWITCH (w/o Memory)
RM27T0E _58 Vehicle Interior _053737 SEAT _0261120 POWER SEAT SWITCH(w/o Memory) G

SEAT  POWER SEAT SWITCH(w/o Memory)  INSPECTION  


PROCEDURE

Hide 84922C 1.INSPECT FRONT POWER SEAT SWITCH LH (for LHD)

a.
B239569E01
0.927,1.354 0.417,1.354 false 0.844,0.344 0.979,0.344 false 0.979,0.344 1.281,1.354 false 1.958,0.344 1.823,0.344 false 1.823,0.344 1.646,1.354 false 2.854,0.365 2.719,0.365 false 2.719,0.365 2.344,1.115 false 2.021,3.146 2.615,2.563 false 1.896,3.125 2.094,2.563 false 1.542,3.135 1.573,2.563 false 1.396,3.135 0.938,2.563 false 2.146,3.156 2.865,2.875 false 1.24,3.135 0.698,2.875 false 2.135,3.354 2.917,3.448 false 2.042,3.365 2.552,3.844 false 1.875,3.375 2.094,3.844 false 1.771,3.385 1.625,4.25 false 1.635,3.333 1.302,3.854 false 1.51,3.365 1.073,3.75 false 0.219,1.281 0.396,1.479 0.177,0.198 10 false *1 0.635,0.26 0.813,0.458 0.177,0.198 10 false *2 1.969,0.26 2.146,0.458 0.177,0.198 10 false *3 2.865,0.26 3.042,0.458 0.177,0.198 10 false *4 0.167,1.938 0.344,2.135 0.177,0.198 10 false *a 2.917,2.802 3.313,2.948 0.396,0.146 10 false FUP 2.417,2.375 2.823,2.521 0.406,0.146 10 false SLDR 1.948,2.375 2.271,2.521 0.323,0.146 10 false LUP 1.302,2.375 1.74,2.521 0.438,0.146 10 false LDWN 0.708,2.375 1.104,2.521 0.396,0.146 10 false SLDF 0.156,2.802 0.594,2.948 0.438,0.146 10 false FDWN 1.208,3.854 1.344,4 0.135,0.146 10 false E 2.938,3.375 3.344,3.521 0.406,0.146 10 false B1 2.521,3.844 2.844,3.99 0.323,0.146 10 false B 1.875,3.844 2.313,3.99 0.438,0.146 10 false RCLR 1.396,4.25 1.792,4.396 0.396,0.146 10 false RCLF 0.833,3.708 1.031,3.854 0.198,0.146 10 false E1

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Slide Switch:
Tester Connection Switch Condition Specified Condition
5 (SLDF) - 8 (B)
5 (SLDF) - 7 (B1)
Front Below 1 Ω
2 (SLDR) - 11 (E)
2 (SLDR) - 12 (E1)
5 (SLDF) - 11 (E)
5 (SLDF) - 12 (E1)
Off
2 (SLDR) - 11 (E)
2 (SLDR) - 12 (E1)
5 (SLDF) - 11 (E)
5 (SLDF) - 12 (E1)
Rear
2 (SLDR) - 8 (B)
2 (SLDR) - 7 (B1)

Front Vertical Switch:
Tester Connection Switch Condition Specified Condition
1 (FUP) - 8 (B)
1 (FUP) - 7 (B1)
Up Below 1 Ω
6 (FDWN) - 11 (E)
6 (FDWN) - 12 (E1)
1 (FUP) - 11 (E)
1 (FUP) - 12 (E1)
Off
6 (FDWN) - 11 (E)
6 (FDWN) - 12 (E1)
1 (FUP) - 11 (E)
1 (FUP) - 12 (E1)
Down
6 (FDWN) - 8 (B)
6 (FDWN) - 7 (B1)

Lifter Switch:
Tester Connection Switch Condition Specified Condition
3 (LUP) - 8 (B)
3 (LUP) - 7 (B1)
Up Below 1 Ω
4 (LDWN) - 11 (E)
4 (LDWN) - 12 (E1)
3 (LUP) - 11 (E)
3 (LUP) - 12 (E1)
Off
4 (LDWN) - 11 (E)
4 (LDWN) - 12 (E1)
3 (LUP) - 11 (E)
3 (LUP) - 12 (E1)
Down
4 (LDWN) - 8 (B)
4 (LDWN) - 7 (B1)

Reclining Switch:
Tester Connection Switch Condition Specified Condition
10 (RCLF) - 8 (B)
10 (RCLF) - 7 (B1)
Front Below 1 Ω
9 (RCLR) - 11 (E)
9 (RCLR) - 12 (E1)
10 (RCLF) - 11 (E)
10 (RCLF) - 12 (E1)
Off
9 (RCLR) - 11 (E)
9 (RCLR) - 12 (E1)
10 (RCLF) - 11 (E)
10 (RCLF) - 12 (E1)
Rear
9 (RCLR) - 8 (B)
9 (RCLR) - 7 (B1)


If the result is not as specified, replace the front power seat switch.

Text in Illustration
*1 Front Vertical Switch
*2 Slide Switch
*3 Lifter Switch
*4 Reclining Switch
*a Component without harness connected
(Front Power Seat Switch)


Hide 84922B 2.INSPECT FRONT POWER SEAT SWITCH RH (for LHD)

a.
B241813E01
0.521,0.271 0.656,0.271 false 0.656,0.271 1.24,1.125 false 2.635,0.25 2.5,0.25 false 2.5,0.25 2.302,1.344 false 2.01,3.135 2.26,2.573 false 1.365,3.125 1.323,2.573 false 1.813,3.385 2.354,4.26 false 1.646,3.385 1.792,3.875 false 1.51,3.385 1.26,4.25 false 0.948,3.885 1.385,3.385 false 2.667,0.156 2.844,0.354 0.177,0.198 10 false *1 0.313,0.188 0.49,0.385 0.177,0.198 10 false *2 0.177,1.948 0.354,2.146 0.177,0.198 10 false *a 2.063,2.385 2.469,2.531 0.406,0.146 10 false SLDF 1.104,2.385 1.5,2.531 0.396,0.146 10 false SLDR 2.302,4.26 2.438,4.406 0.135,0.146 10 false E 1.021,4.25 1.458,4.396 0.438,0.146 10 false RCLR 1.563,3.885 1.958,4.031 0.396,0.146 10 false RCLF 0.833,3.885 1.01,4.031 0.177,0.146 10 false B

for 4 Way Seat Type:

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Slide Switch:
Tester Connection Switch Condition Specified Condition
2 (SLDF) - 13 (B) Front Below 1 Ω
5 (SLDR) - 10 (E)
2 (SLDF) - 10 (E) Off
5 (SLDR) - 10 (E)
2 (SLDF) - 10 (E) Rear
5 (SLDR) - 13 (B)

Reclining Switch:
Tester Connection Switch Condition Specified Condition
11 (RCLF) - 13 (B) Front Below 1 Ω
12 (RCLR) - 10 (E)
11 (RCLF) - 10 (E) Off
12 (RCLR) - 10 (E)
11 (RCLF) - 10 (E) Rear
12 (RCLR) - 13 (B)


If the result is not as specified, replace the front power seat switch.

Text in Illustration
*1 Slide Switch
*2 Reclining Switch
*a Component without harness connected
(Front Power Seat Switch)


b.
B239570E04
3.171,1.28 3.349,1.473 0.178,0.193 10 *1 2.678,0.261 2.856,0.454 0.178,0.193 10 *2 1.205,0.261 1.383,0.454 0.178,0.193 10 *3 0.433,0.261 0.611,0.454 0.178,0.193 10 *4 0.168,1.938 0.346,2.130 0.178,0.193 10 *a 3.141,1.357 2.648,1.357 false 2.655,0.348 2.517,0.348 false 2.517,0.348 2.294,1.355 false 1.414,0.348 1.551,0.348 false 1.551,0.348 1.927,1.355 false 0.643,0.373 0.78,0.373 false 0.78,0.373 1.235,1.115 false 0.324,2.797 0.720,2.941 0.395,0.143 10 FUP 0.569,2.393 0.978,2.537 0.409,0.143 10 SLDR 1.3,2.393 1.626,2.537 0.326,0.143 10 LUP 1.832,2.393 2.274,2.537 0.442,0.143 10 LDWN 2.56,2.393 2.955,2.537 0.395,0.143 10 SLDF 2.819,2.984 3.261,3.127 0.442,0.143 10 FDWN 2.055,3.123 2.765,2.565 false 1.901,3.12 2.09,2.565 false 1.527,3.119 1.471,2.565 false 1.36,3.115 0.81,2.565 false 2.176,3.136 2.789,3.056 false 1.241,3.118 0.699,2.878 false 2.17,4.149 2.311,4.292 0.140,0.143 10 E 0.371,3.349 0.586,3.492 0.215,0.143 10 B1 0.509,3.916 0.647,4.059 0.139,0.143 10 B 0.758,4.149 1.200,4.292 0.442,0.143 10 RCLR 1.41,3.916 1.805,4.059 0.395,0.143 10 RCLF 2.498,3.916 2.773,4.059 0.275,0.143 10 E1 0.595,3.42 1.231,3.292 false 1.367,3.39 0.636,3.916 false 1.899,3.394 2.5,3.894 false 1.766,3.39 2.195,4.137 false 1.646,3.389 1.645,3.898 false 1.481,3.393 1.025,4.136 false

for 8 Way Seat Type:

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Slide Switch:
Tester Connection Switch Condition Specified Condition
2 (SLDF) - 13 (B)
2 (SLDF) - 14 (B1)
Front Below 1 Ω
5 (SLDR) - 10 (E)
5 (SLDR) - 9 (E1)
2 (SLDF) - 10 (E)
2 (SLDF) - 9 (E1)
Off
5 (SLDR) - 10 (E)
5 (SLDR) - 9 (E1)
2 (SLDF) - 10 (E)
2 (SLDF) - 9 (E1)
Rear
5 (SLDR) - 13 (B)
5 (SLDR) - 14 (B1)

Front Vertical Switch:
Tester Connection Switch Condition Specified Condition
6 (FUP) - 13 (B)
6 (FUP) - 14 (B1)
Up Below 1 Ω
1 (FDWN) - 10 (E)
1 (FDWN) - 9 (E1)
6 (FUP) - 10 (E)
6 (FUP) - 9 (E1)
Off
1 (FDWN) - 10 (E)
1 (FDWN) - 9 (E1)
6 (FUP) - 10 (E)
6 (FUP) - 9 (E1)
Down
1 (FDWN) - 13 (B)
1 (FDWN) - 14 (B1)

Lifter Switch:
Tester Connection Switch Condition Specified Condition
4 (LUP) - 13 (B)
4 (LUP) - 14 (B1)
Up Below 1 Ω
3 (LDWN) - 10 (E)
3 (LDWN) - 9 (E1)
4 (LUP) - 10 (E)
4 (LUP) - 9 (E1)
Off
3 (LDWN) - 10 (E)
3 (LDWN) - 9 (E1)
4 (LUP) - 10 (E)
4 (LUP) - 9 (E1)
Down
3 (LDWN) - 13 (B)
3 (LDWN) - 14 (B1)

Reclining Switch:
Tester Connection Switch Condition Specified Condition
11 (RCLF) - 13 (B)
11 (RCLF) - 14 (B1)
Front Below 1 Ω
12 (RCLR) - 10 (E)
12 (RCLR) - 9 (E1)
11 (RCLF) - 10 (E)
11 (RCLF) - 9 (E1)
Off
12 (RCLR) - 10 (E)
12 (RCLR) - 9 (E1)
11 (RCLF) - 10 (E)
11 (RCLF) - 9 (E1)
Rear
12 (RCLR) - 13 (B)
12 (RCLR) - 14 (B1)


If the result is not as specified, replace the front power seat switch.

Text in Illustration
*1 Front Vertical Switch
*2 Slide Switch
*3 Lifter Switch
*4 Reclining Switch
*a Component without harness connected
(Front Power Seat Switch)


Hide 84922B 3.INSPECT FRONT POWER SEAT SWITCH RH (for RHD)

a.
B239570E04
3.171,1.28 3.349,1.473 0.178,0.193 10 *1 2.678,0.261 2.856,0.454 0.178,0.193 10 *2 1.205,0.261 1.383,0.454 0.178,0.193 10 *3 0.433,0.261 0.611,0.454 0.178,0.193 10 *4 0.168,1.938 0.346,2.130 0.178,0.193 10 *a 3.141,1.357 2.648,1.357 false 2.655,0.348 2.517,0.348 false 2.517,0.348 2.294,1.355 false 1.414,0.348 1.551,0.348 false 1.551,0.348 1.927,1.355 false 0.643,0.373 0.78,0.373 false 0.78,0.373 1.235,1.115 false 0.324,2.797 0.720,2.941 0.395,0.143 10 FUP 0.569,2.393 0.978,2.537 0.409,0.143 10 SLDR 1.3,2.393 1.626,2.537 0.326,0.143 10 LUP 1.832,2.393 2.274,2.537 0.442,0.143 10 LDWN 2.56,2.393 2.955,2.537 0.395,0.143 10 SLDF 2.819,2.984 3.261,3.127 0.442,0.143 10 FDWN 2.055,3.123 2.765,2.565 false 1.901,3.12 2.09,2.565 false 1.527,3.119 1.471,2.565 false 1.36,3.115 0.81,2.565 false 2.176,3.136 2.789,3.056 false 1.241,3.118 0.699,2.878 false 2.17,4.149 2.311,4.292 0.140,0.143 10 E 0.371,3.349 0.586,3.492 0.215,0.143 10 B1 0.509,3.916 0.647,4.059 0.139,0.143 10 B 0.758,4.149 1.200,4.292 0.442,0.143 10 RCLR 1.41,3.916 1.805,4.059 0.395,0.143 10 RCLF 2.498,3.916 2.773,4.059 0.275,0.143 10 E1 0.595,3.42 1.231,3.292 false 1.367,3.39 0.636,3.916 false 1.899,3.394 2.5,3.894 false 1.766,3.39 2.195,4.137 false 1.646,3.389 1.645,3.898 false 1.481,3.393 1.025,4.136 false

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Slide Switch:
Tester Connection Switch Condition Specified Condition
2 (SLDF) - 13 (B)
2 (SLDF) - 14 (B1)
Front Below 1 Ω
5 (SLDR) - 10 (E)
5 (SLDR) - 9 (E1)
2 (SLDF) - 10 (E)
2 (SLDF) - 9 (E1)
Off
5 (SLDR) - 10 (E)
5 (SLDR) - 9 (E1)
2 (SLDF) - 10 (E)
2 (SLDF) - 9 (E1)
Rear
5 (SLDR) - 13 (B)
5 (SLDR) - 14 (B1)

Front Vertical Switch:
Tester Connection Switch Condition Specified Condition
6 (FUP) - 13 (B)
6 (FUP) - 14 (B1)
Up Below 1 Ω
1 (FDWN) - 10 (E)
1 (FDWN) - 9 (E1)
6 (FUP) - 10 (E)
6 (FUP) - 9 (E1)
Off
1 (FDWN) - 10 (E)
1 (FDWN) - 9 (E1)
6 (FUP) - 10 (E)
6 (FUP) - 9 (E1)
Down
1 (FDWN) - 13 (B)
1 (FDWN) - 14 (B1)

Lifter Switch:
Tester Connection Switch Condition Specified Condition
4 (LUP) - 13 (B)
4 (LUP) - 14 (B1)
Up Below 1 Ω
3 (LDWN) - 10 (E)
3 (LDWN) - 9 (E1)
4 (LUP) - 10 (E)
4 (LUP) - 9 (E1)
Off
3 (LDWN) - 10 (E)
3 (LDWN) - 9 (E1)
4 (LUP) - 10 (E)
4 (LUP) - 9 (E1)
Down
3 (LDWN) - 13 (B)
3 (LDWN) - 14 (B1)

Reclining Switch:
Tester Connection Switch Condition Specified Condition
11 (RCLF) - 13 (B)
11 (RCLF) - 14 (B1)
Front Below 1 Ω
12 (RCLR) - 10 (E)
12 (RCLR) - 9 (E1)
11 (RCLF) - 10 (E)
11 (RCLF) - 9 (E1)
Off
12 (RCLR) - 10 (E)
12 (RCLR) - 9 (E1)
11 (RCLF) - 10 (E)
11 (RCLF) - 9 (E1)
Rear
12 (RCLR) - 13 (B)
12 (RCLR) - 14 (B1)


If the result is not as specified, replace the front power seat switch.

Text in Illustration
*1 Front Vertical Switch
*2 Slide Switch
*3 Lifter Switch
*4 Reclining Switch
*a Component without harness connected
(Front Power Seat Switch)


Hide 84922C 4.INSPECT FRONT POWER SEAT SWITCH LH (for RHD)

a.
B241814E01
0.765,0.195 0.943,0.388 0.178,0.193 10 *1 3.102,0.195 3.280,0.388 0.178,0.193 10 *2 0.168,1.946 0.346,2.139 0.178,0.193 10 *a 3.07,0.283 2.932,0.283 false 2.932,0.283 2.348,1.106 false 0.94,0.271 1.078,0.271 false 1.078,0.271 1.284,1.365 false 1.123,2.385 1.533,2.528 0.409,0.143 10 SLDF 2.002,2.385 2.398,2.528 0.395,0.143 10 SLDR 2.021,3.132 2.219,2.573 false 1.394,3.123 1.352,2.573 false 1.053,4.28 1.193,4.423 0.140,0.143 10 E 1.947,4.28 2.444,4.423 0.497,0.143 10 RCLR 1.472,3.886 1.868,4.029 0.395,0.143 10 RCLF 1.899,3.386 2.188,4.277 false 1.766,3.381 1.696,3.871 false 1.643,3.383 1.128,4.277 false 2.399,3.886 2.539,4.029 0.140,0.143 10 B 2.062,3.384 2.381,3.883 false

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Slide Switch:
Tester Connection Switch Condition Specified Condition
5 (SLDF) - 8 (B) Front Below 1 Ω
2 (SLDR) - 11 (E)
5 (SLDF) - 11 (E) Off
2 (SLDR) - 11 (E)
5 (SLDF) - 11 (E) Rear
2 (SLDR) - 8 (B)

Reclining Switch:
Tester Connection Switch Condition Specified Condition
10 (RCLF) - 8 (B) Front Below 1 Ω
9 (RCLR) - 11 (E)
10 (RCLF) - 11 (E) Off
9 (RCLR) - 11 (E)
10 (RCLF) - 11 (E) Rear
9 (RCLR) - 8 (B)


If the result is not as specified, replace the front power seat switch.

Text in Illustration
*1 Slide Switch
*2 Reclining Switch
*a Component without harness connected
(Front Power Seat Switch)