Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING PRESSURE SENSOR
RM27T0E _58 Vehicle Interior _053739 HEATING / AIR CONDITIONING _0261194 AIR CONDITIONING PRESSURE SENSOR G

HEATING / AIR CONDITIONING  AIR CONDITIONING PRESSURE SENSOR  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 88645H 1.INSPECT NO. 1 PRESSURE SWITCH

a.

Install a manifold gauge set.


b.

Disconnect the connector from the No. 1 pressure switch.


c.
I033643E05
1.615,0.958 1.229,0.573 true 1.823,0.958 2.208,0.573 true 1.125,0.396 1.229,0.552 0.104,0.156 10 false 1 2.219,0.406 2.323,0.552 0.104,0.146 10 false 2 0.552,2.646 1.094,2.813 0.542,0.167 10 false 196 kPa 2.594,2.646 3.26,2.802 0.667,0.156 10 false 3140 kPa 0.125,0.188 0.333,0.375 0.208,0.188 10 false *a 0.823,1.833 1.031,2.021 0.208,0.188 10 false *b 1.656,1.833 1.833,2.01 0.177,0.177 10 false *c 2.552,1.833 2.729,2.031 0.177,0.198 10 false *d 0.729,3.063 0.938,3.219 0.208,0.156 10 false *e 2.708,3.063 2.875,3.219 0.167,0.156 10 false *e 0.188,2.833 1.427,3.052 1.24,0.219 10 false (2.0 kgf*cm, 28 psi) 2.052,2.833 3.417,3.042 1.365,0.208 10 false (32.0 kgf*cm, 455 psi)

Connect the positive (+) lead from the ohmmeter to terminal 1 and the negative (-) lead to terminal 2.

Text in Illustration
*a Component without harness connected
(No. 1 Pressure Switch)
*b Low Pressure Side
*c On (Below 1.0 Ω)
*d High Pressure Side
*e Off (10 kΩ or higher)


d.

Check the resistance between terminals when refrigerant pressure is charged as shown in the illustration.

If operation is not as specified, replace the No. 1 pressure switch.


Hide 88719A 2.INSPECT AIR CONDITIONING PRESSURE SENSOR

a.

Install a manifold gauge set.


b.

Disconnect the connector from the air conditioning pressure sensor.


c.
E350011E01
1.125,0.875 0.875,0.406 0.875,0.406 0.688,0.406 true 0.938,0.865 0.646,0.708 0.646,0.708 0.5,0.708 true 1.354,0.875 1.354,1.438 1.354,1.438 1.51,1.438 true 0.073,0.052 0.385,0.25 0.313,0.198 10 false *a 0.635,1.896 0.948,2.094 0.313,0.198 10 false *b 1.583,4.365 1.896,4.563 0.313,0.198 10 false *c 0.271,0.323 0.688,0.531 0.417,0.208 10 false 2 (PR) 0.198,0.625 0.531,0.854 0.333,0.229 10 false 3 (+) 1.542,1.344 1.854,1.594 0.313,0.25 10 false 1 (-)

Connect the positive (+) lead of a DC 5 V power source to terminal 3 and the negative (-) lead to terminal 1.

Text in Illustration
*a Component without harness connected
(Air Conditioning Pressure Sensor)
*b Voltage
*c Refrigerant Pressure


d.

Connect the positive (+) lead of the voltmeter to terminal 2 and the negative (-) lead to terminal 1.


e.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
2 (PR) - 1 (-) Refrigerant pressure:
0.39 to 3.187 MPa (57 to 463 psi)
0.93 to 4.9 V


If the result is not as specified, replace the air conditioning pressure sensor.