88645H
1.INSPECT NO. 1 PRESSURE SWITCH
Install a manifold gauge set.
Disconnect the connector from the No. 1 pressure switch.
Connect the positive (+) lead from the ohmmeter to terminal 1 and the negative (-) lead to terminal 2.
| *a | Component without harness connected
(No. 1 Pressure Switch) |
| *b | Low Pressure Side |
| *c | On (Below 1.0 Ω) |
| *d | High Pressure Side |
| *e | Off (10 kΩ or higher) |
Check the resistance between terminals when refrigerant pressure is charged as shown in the illustration.
If operation is not as specified, replace the No. 1 pressure switch.
88719A
2.INSPECT AIR CONDITIONING PRESSURE SENSOR
Install a manifold gauge set.
Disconnect the connector from the air conditioning pressure sensor.
Connect the positive (+) lead of a DC 5 V power source to terminal 3 and the negative (-) lead to terminal 1.
| *a | Component without harness connected
(Air Conditioning Pressure Sensor) |
| *b | Voltage |
| *c | Refrigerant Pressure |
Connect the positive (+) lead of the voltmeter to terminal 2 and the negative (-) lead to terminal 1.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2 (PR) - 1 (-) | Refrigerant pressure:
0.39 to 3.187 MPa (57 to 463 psi) |
0.93 to 4.9 V |
If the result is not as specified, replace the air conditioning pressure sensor.