Home › Vehicle Exterior › WINDOW / GLASS › RELAY(w/ Heated Windshield Defroster System) › from 2017.08
RM27T0E _59 Vehicle Exterior _053742 WINDOW / GLASS _0327162 RELAY(w/ Heated Windshield Defroster System) G

WINDOW / GLASS  RELAY(w/ Heated Windshield Defroster System)  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 85912F 1.INSPECT HWD NO. 1 RELAY

a.
B488898

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 4 Battery voltage not applied between terminals 1 and 2 Below 1 Ω
Battery voltage applied between terminals 1 and 2 10 kΩ or higher
3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
Battery voltage applied to terminals 1 and 2 Below 1 Ω
4 - 5 Always 10 kΩ or higher


If the result is not as specified, replace the HWD No. 1 relay.


Hide 85912F 2.INSPECT HWD NO. 2 RELAY

a.
B488898

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 4 Battery voltage not applied between terminals 1 and 2 Below 1 Ω
Battery voltage applied between terminals 1 and 2 10 kΩ or higher
3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
Battery voltage applied to terminals 1 and 2 Below 1 Ω
4 - 5 Always 10 kΩ or higher


If the result is not as specified, replace the HWD No. 2 relay.


Hide 85912F 3.INSPECT HWD NO. 3 RELAY

a.
B488898

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 4 Battery voltage not applied between terminals 1 and 2 Below 1 Ω
Battery voltage applied between terminals 1 and 2 10 kΩ or higher
3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
Battery voltage applied to terminals 1 and 2 Below 1 Ω
4 - 5 Always 10 kΩ or higher


If the result is not as specified, replace the HWD No. 3 relay.


Hide 85912F 4.INSPECT HWD NO. 4 RELAY

a.
B488898

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 4 Battery voltage not applied between terminals 1 and 2 Below 1 Ω
Battery voltage applied between terminals 1 and 2 10 kΩ or higher
3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
Battery voltage applied to terminals 1 and 2 Below 1 Ω
4 - 5 Always 10 kΩ or higher


If the result is not as specified, replace the HWD No. 4 relay.