85912F
1.INSPECT HWD NO. 1 RELAY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 4 | Battery voltage not applied between terminals 1 and 2 | Below 1 Ω |
| Battery voltage applied between terminals 1 and 2 | 10 kΩ or higher | |
| 3 - 5 | Battery voltage not applied to terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage applied to terminals 1 and 2 | Below 1 Ω | |
| 4 - 5 | Always | 10 kΩ or higher |
If the result is not as specified, replace the HWD No. 1 relay.
85912F
2.INSPECT HWD NO. 2 RELAY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 4 | Battery voltage not applied between terminals 1 and 2 | Below 1 Ω |
| Battery voltage applied between terminals 1 and 2 | 10 kΩ or higher | |
| 3 - 5 | Battery voltage not applied to terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage applied to terminals 1 and 2 | Below 1 Ω | |
| 4 - 5 | Always | 10 kΩ or higher |
If the result is not as specified, replace the HWD No. 2 relay.
85912F
3.INSPECT HWD NO. 3 RELAY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 4 | Battery voltage not applied between terminals 1 and 2 | Below 1 Ω |
| Battery voltage applied between terminals 1 and 2 | 10 kΩ or higher | |
| 3 - 5 | Battery voltage not applied to terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage applied to terminals 1 and 2 | Below 1 Ω | |
| 4 - 5 | Always | 10 kΩ or higher |
If the result is not as specified, replace the HWD No. 3 relay.
85912F
4.INSPECT HWD NO. 4 RELAY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 4 | Battery voltage not applied between terminals 1 and 2 | Below 1 Ω |
| Battery voltage applied between terminals 1 and 2 | 10 kΩ or higher | |
| 3 - 5 | Battery voltage not applied to terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage applied to terminals 1 and 2 | Below 1 Ω | |
| 4 - 5 | Always | 10 kΩ or higher |
If the result is not as specified, replace the HWD No. 4 relay.