Home › Audio / Visual / Telematics › PARK ASSIST / MONITORING › ULTRASONIC SENSOR(for Front) › from 2017.08
RM27T0E _56 Audio / Visual / Telematics _053722 PARK ASSIST / MONITORING _0260997 ULTRASONIC SENSOR(for Front) G

PARK ASSIST / MONITORING  ULTRASONIC SENSOR(for Front)  INSPECTION  


PROCEDURE

Hide 89341K 1.INSPECT FRONT CORNER ULTRASONIC SENSOR

a.
B488740C01
1.49,0.969 0.875,0.521 true 1.76,0.927 1.76,0.302 1.76,0.302 2.188,0.302 true 1.5,1.198 0.729,1.198 true 2.042,0.969 2.656,0.969 true 1.313,1.865 1.729,1.865 1.729,1.865 1.729,1.24 true 2.042,1.208 2.656,1.552 true 0.052,0.052 0.365,0.208 0.313,0.156 10 false *a 0.49,1.115 0.802,1.313 0.313,0.198 10 false BO 0.688,0.427 1,0.625 0.313,0.198 10 false BI 1.063,1.771 1.375,1.969 0.313,0.198 10 false SO 2.24,0.208 2.552,0.406 0.313,0.198 10 false SI 2.719,1.5 3.031,1.698 0.313,0.198 10 false EO 2.708,0.885 3.021,1.083 0.313,0.198 10 false EI
*a Component without harness connected
(Front Corner Ultrasonic Sensor)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 (BI) - 5 (EI) Always 10 kΩ or higher
1 (BI) - 2 (BO) Always 10 kΩ or higher
3 (SI) - 4 (SO) Always Below 1 Ω
5 (EI) - 6 (EO) Always Below 1 Ω


If the result is not as specified, replace the front corner ultrasonic sensor.


Hide 89341L 2.INSPECT FRONT CENTER ULTRASONIC SENSOR

a.
B488740C01
1.49,0.969 0.875,0.521 true 1.76,0.927 1.76,0.302 1.76,0.302 2.188,0.302 true 1.5,1.198 0.729,1.198 true 2.042,0.969 2.656,0.969 true 1.313,1.865 1.729,1.865 1.729,1.865 1.729,1.24 true 2.042,1.208 2.656,1.552 true 0.052,0.052 0.365,0.208 0.313,0.156 10 false *a 0.49,1.115 0.802,1.313 0.313,0.198 10 false BO 0.688,0.427 1,0.625 0.313,0.198 10 false BI 1.063,1.771 1.375,1.969 0.313,0.198 10 false SO 2.24,0.208 2.552,0.406 0.313,0.198 10 false SI 2.719,1.5 3.031,1.698 0.313,0.198 10 false EO 2.708,0.885 3.021,1.083 0.313,0.198 10 false EI
*a Component without harness connected
(Front Center Ultrasonic Sensor)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 (BI) - 5 (EI) Always 10 kΩ or higher
1 (BI) - 2 (BO) Always 10 kΩ or higher
3 (SI) - 4 (SO) Always Below 1 Ω
5 (EI) - 6 (EO) Always Below 1 Ω


If the result is not as specified, replace the front corner ultrasonic sensor.