Home › Audio / Visual / Telematics › PARK ASSIST / MONITORING › ULTRASONIC SENSOR(for Rear) › from 2017.08
RM27T0E _56 Audio / Visual / Telematics _053722 PARK ASSIST / MONITORING _0260998 ULTRASONIC SENSOR(for Rear) G

PARK ASSIST / MONITORING  ULTRASONIC SENSOR(for Rear)  INSPECTION  


PROCEDURE

Hide 89342 1.INSPECT REAR CORNER ULTRASONIC SENSOR

a.
B488740C01
1.49,0.969 0.875,0.521 true 1.76,0.927 1.76,0.302 1.76,0.302 2.188,0.302 true 1.5,1.198 0.729,1.198 true 2.042,0.969 2.656,0.969 true 1.313,1.865 1.729,1.865 1.729,1.865 1.729,1.24 true 2.042,1.208 2.656,1.552 true 0.052,0.052 0.365,0.208 0.313,0.156 10 false *a 0.49,1.115 0.802,1.313 0.313,0.198 10 false BO 0.688,0.427 1,0.625 0.313,0.198 10 false BI 1.063,1.771 1.375,1.969 0.313,0.198 10 false SO 2.24,0.208 2.552,0.406 0.313,0.198 10 false SI 2.719,1.5 3.031,1.698 0.313,0.198 10 false EO 2.708,0.885 3.021,1.083 0.313,0.198 10 false EI
*a Component without harness connected
(Rear Corner Ultrasonic Sensor)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 (BI) - 5 (EI) Always 10 kΩ or higher
1 (BI) - 2 (BO) Always 10 kΩ or higher
3 (SI) - 4 (SO) Always Below 1 Ω
5 (EI) - 6 (EO) Always Below 1 Ω


If the result is not as specified, replace the rear corner ultrasonic sensor.


Hide 89342A 2.INSPECT REAR CENTER ULTRASONIC SENSOR

a.
B488740C01
1.49,0.969 0.875,0.521 true 1.76,0.927 1.76,0.302 1.76,0.302 2.188,0.302 true 1.5,1.198 0.729,1.198 true 2.042,0.969 2.656,0.969 true 1.313,1.865 1.729,1.865 1.729,1.865 1.729,1.24 true 2.042,1.208 2.656,1.552 true 0.052,0.052 0.365,0.208 0.313,0.156 10 false *a 0.49,1.115 0.802,1.313 0.313,0.198 10 false BO 0.688,0.427 1,0.625 0.313,0.198 10 false BI 1.063,1.771 1.375,1.969 0.313,0.198 10 false SO 2.24,0.208 2.552,0.406 0.313,0.198 10 false SI 2.719,1.5 3.031,1.698 0.313,0.198 10 false EO 2.708,0.885 3.021,1.083 0.313,0.198 10 false EI
*a Component without harness connected
(Rear Center Ultrasonic Sensor)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 (BI) - 5 (EI) Always 10 kΩ or higher
1 (BI) - 2 (BO) Always 10 kΩ or higher
3 (SI) - 4 (SO) Always Below 1 Ω
5 (EI) - 6 (EO) Always Below 1 Ω


If the result is not as specified, replace the rear corner ultrasonic sensor.