1GD-FTV ENGINE CONTROL  RELAY(w/ Urea SCR System)  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 82641 1.INSPECT NO. 1 INTEGRATION RELAY

A406470C01
1.438,2 1.75,2.198 0.313,0.198 2.438,1.99 2.75,2.188 0.313,0.198 3.531,1.99 3.844,2.188 0.313,0.198 4.573,1.99 4.885,2.188 0.313,0.198 5.531,2 5.844,2.198 0.313,0.198 0.094,0.094 0.469,0.406 0.375,0.313 10 false *a 1.51,2.021 1.813,2.26 0.302,0.24 10 false 1T 2.51,2.01 2.813,2.25 0.302,0.24 10 false 1U 3.604,2.01 3.906,2.25 0.302,0.24 10 false 1V 4.615,2.01 4.917,2.25 0.302,0.24 10 false 1W 5.604,2.021 5.906,2.26 0.302,0.24 10 false 1S
*a Component without harness connected
(No. 1 Integration Relay)
- -


NOTICE:
·

The EDU relay, IG2 relay, EFI MAIN NO. 1 relay and EFI MAIN NO. 2 relay are built into the No. 1 integration relay.

·

Before performing the relay inspections for the relays of the No. 1 integration relay, inspect the EDU, IG2, EFI MAIN NO. 1 and EFI MAIN NO. 2 fuses.



a.

Inspect the EDU relay.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1S-1 - 1U-2 Battery voltage not applied to terminals 1U-3 and 1U-1 10 kΩ or higher
Battery voltage applied to terminals 1U-3 and 1U-1 Below 1 Ω


If the result is not as specified, replace the No. 1 integration relay.



b.

Inspect the IG2 relay.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1S-1 - 1V-1 Battery voltage not applied to terminals 1V-2 and 1W-4 10 kΩ or higher
Battery voltage applied to terminals 1V-2 and 1W-4 Below 1 Ω


If the result is not as specified, replace the No. 1 integration relay.



c.

Inspect the EFI MAIN NO. 1 relay.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1S-1 - 1W-10 Battery voltage not applied to terminals 1W-8 and 1W-4 10 kΩ or higher
Battery voltage applied to terminals 1W-8 and 1W-4 Below 1 Ω


If the result is not as specified, replace the No. 1 integration relay.



d.

Inspect the EFI MAIN NO. 2 relay.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1S-1 - 1W-3 Battery voltage not applied to terminals 1W-1 and 1W-4 10 kΩ or higher
Battery voltage applied to terminals 1W-1 and 1W-4 Below 1 Ω


If the result is not as specified, replace the No. 1 integration relay.



Hide 896B1A 2.INSPECT DCU RELAY (DCU)

a.
A301376N10
2.344,0.771 2.656,0.469 2.656,0.469 2.719,0.469 false 2.313,1.458 2.063,1.75 2.063,1.75 1.979,1.75 false 1.917,1.115 1.656,1.115 false 2.688,1.104 3.021,1.104 false 0.292,1.313 0.438,1.49 0.146,0.177 10 false 1 1.271,1.302 1.417,1.479 0.146,0.177 10 false 2 0.302,0.781 0.448,0.958 0.146,0.177 10 false 3 1.281,0.781 1.427,0.958 0.146,0.177 10 false 5 2.76,0.396 2.906,0.573 0.146,0.177 10 false 1 1.875,1.667 2.021,1.844 0.146,0.177 10 false 2 1.49,1 1.635,1.177 0.146,0.177 10 false 3 3.073,1.021 3.219,1.198 0.146,0.177 10 false 5

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
Battery voltage applied to terminals 1 and 2 Below 1 Ω


If the result is not as specified, replace the DCU relay.


Hide 89463B 3.INSPECT NOx PM RELAY (NOx PM)

a.
A167865N33
1.99,0.719 1.531,0.365 false 2.667,0.677 3.073,0.302 false 2.542,1.125 3.073,1.125 false 2.542,1.625 3.083,1.625 false 0.198,0.74 0.333,0.99 0.135,0.25 10 false 5 1.198,0.781 1.365,0.99 0.167,0.208 10 false 3 0.208,1.302 0.365,1.594 0.156,0.292 10 false 2 1.198,1.281 1.385,1.5 0.188,0.219 10 false 1 1.396,0.229 1.583,0.448 0.188,0.219 10 false 1 3.115,0.188 3.271,0.479 0.156,0.292 10 false 2 3.146,1.531 3.313,1.74 0.167,0.208 10 false 3 3.146,1.031 3.281,1.281 0.135,0.25 10 false 5

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
Battery voltage applied to terminals 1 and 2 Below 1 Ω


If the result is not as specified, replace the NOx PM relay.