Hide 82641 1.INSPECT NO. 1 INTEGRATION RELAY

A406470C01
1.438,2 1.75,2.198 0.313,0.198 2.438,1.99 2.75,2.188 0.313,0.198 3.531,1.99 3.844,2.188 0.313,0.198 4.573,1.99 4.885,2.188 0.313,0.198 5.531,2 5.844,2.198 0.313,0.198 0.094,0.094 0.469,0.406 0.375,0.313 10 false *a 1.51,2.021 1.813,2.26 0.302,0.24 10 false 1T 2.51,2.01 2.813,2.25 0.302,0.24 10 false 1U 3.604,2.01 3.906,2.25 0.302,0.24 10 false 1V 4.615,2.01 4.917,2.25 0.302,0.24 10 false 1W 5.604,2.021 5.906,2.26 0.302,0.24 10 false 1S
*a Component without harness connected
(No. 1 Integration Relay)
- -


NOTICE:
·

The EDU relay, IG2 relay, EFI MAIN NO. 1 relay, EFI MAIN NO. 2 and FUEL PMP relay are built into the No. 1 integration relay.

·

Before performing the relay inspections for the relays of the No. 1 integration relay, inspect the EDU, IG2, EFI MAIN NO. 1, EFI MAIN NO. 2 and FUEL PMP fuses.



a.

Inspect the EDU relay.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1S-1 - 1U-2 Battery voltage not applied to terminals 1U-3 and 1U-1 10 kΩ or higher
Battery voltage applied to terminals 1U-3 and 1U-1 Below 1 Ω


If the result is not as specified, replace the No. 1 integration relay.



b.

Inspect the IG2 relay.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1S-1 - 1V-1 Battery voltage not applied to terminals 1V-2 and 1W-4 10 kΩ or higher
Battery voltage applied to terminals 1V-2 and 1W-4 Below 1 Ω


If the result is not as specified, replace the No. 1 integration relay.



c.

Inspect the EFI MAIN NO. 1 relay.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1S-1 - 1W-10 Battery voltage not applied to terminals 1W-8 and 1W-4 10 kΩ or higher
Battery voltage applied to terminals 1W-8 and 1W-4 Below 1 Ω


If the result is not as specified, replace the No. 1 integration relay.



d.

Inspect the EFI MAIN NO. 2 relay.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1S-1 - 1W-3 Battery voltage not applied to terminals 1W-1 and 1W-4 10 kΩ or higher
Battery voltage applied to terminals 1W-1 and 1W-4 Below 1 Ω


If the result is not as specified, replace the No. 1 integration relay.



e.

Inspect the FUEL PMP relay.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1S-1 - 1V-6 Battery voltage not applied to terminals 1S-1 and 1V-7 10 kΩ or higher
Battery voltage applied to terminals 1S-1 and 1V-7 Below 1 Ω


If the result is not as specified, replace the No. 1 integration relay.