When the ignition switch is turned to ON, battery voltage is applied to terminal IGSW of the ECM. The output signal from the MREL terminal of the ECM causes current to flow to the coil, closing the contacts of the integration relay (EFI relay) and supplying power to terminal +B of the ECM.
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C153-3 (E1) - Body ground | Always | Below 1 Ω |
OK
NG
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| G180-8 (IGSW) - Body ground | Ignition switch ON | 11 to 14 V |
| *a | Rear view of wire harness connector
(to ECM) |
OK
NG
Inspect the No. 1 integration relay (EFI MAIN NO. 1 relay) (See page Engine / Hybrid System>2TR-FE (ENGINE CONTROL)>RELAY>ON-VEHICLE INSPECTION).
OK
NG
Remove the No. 1 integration relay from the engine room relay block and junction block assembly.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1W-10 - G180-1 (+B) | Always | Below 1 Ω |
| 1W-10 - G180-2 (+B2) | Always | Below 1 Ω |
| 1W-10 or G180-1 (+B) - Body ground | Always | 10 kΩ or higher |
| 1W-10 or G180-2 (+B2) - Body ground | Always | 10 kΩ or higher |
OK
NG
Remove the No. 1 integration relay from the engine room relay block and junction block assembly.
Disconnect the cable from the negative (-) battery terminal.
Disconnect the cable from the positive (+) battery terminal.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1S-1 - Positive battery terminal | Always | Below 1 Ω |
| 1S-1 or Positive battery terminal - Body ground | Always | 10 kΩ or higher |
OK
NG
Remove the No. 1 integration relay from the engine room relay block and junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1W-4 - Body ground | Always | Below 1 Ω |
OK
NG
Disconnect the ECM connector.
Remove the No. 1 integration relay from the engine room relay block and junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1W-8 - G181-6 (MREL) | Always | Below 1 Ω |
| 1W-8 or G181-6 (MREL) - Body ground | Always | 10 kΩ or higher |
OK
NG
Inspect the NO. 1 integration relay (IG2 relay) (See page Engine / Hybrid System>2TR-FE (ENGINE CONTROL)>RELAY>ON-VEHICLE INSPECTION).
OK
NG
Disconnect the ECM connector.
Remove the No. 1 integration relay from the engine room relay block and junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1V-1 - G180-8 (IGSW) | Always | Below 1 Ω |
| 1V-1 or G180-8 (IGSW) - Body ground | Always | 10 kΩ or higher |
OK
NG
Remove the No. 1 integration relay from the engine room relay block and junction block assembly.
Disconnect the cable from the negative (-) battery terminal.
Disconnect the cable from the positive (+) battery terminal.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1S-1 - Positive battery terminal | Always | Below 1 Ω |
| 1S-1 or Positive battery terminal - Body ground | Always | 10 kΩ or higher |
OK
NG
Remove the No. 1 integration relay from the engine room relay block and junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1W-4 - Body ground | Always | Below 1 Ω |
OK
NG
Confirm the entry and start system.
| Result | Proceed to |
|---|---|
| w/ Entry and Start System | A |
| w/o Entry and Start System | B |
A
B
Remove the No. 1 integration relay from the engine room relay block and junction block assembly.
Disconnect the certification ECU (smart key ECU assembly) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G213-3 (IG1D) - 1V-2 | Always | Below 1 Ω |
| G213-3 (IG1D) or 1V-2 - Body ground | Always | 10 kΩ or higher |
OK
NG
Disconnect the ignition switch connector.
Remove the No. 1 integration relay from the engine room relay block and junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1V-2 - G2-6 (IG2) | Always | Below 1 Ω |
| 1V-2 or G2-6 (IG2) - Body ground | Always | 10 kΩ or higher |
OK
NG
Inspect the ignition switch assembly (See page Engine / Hybrid System>2TR-FE (STARTING)>IGNITION SWITCH>INSPECTION).
OK
NG