Home › Engine / Hybrid System › 1GD-FTV (ENGINE CONTROL) › ECD SYSTEM (w/ Urea SCR System) › 2018.06–2020.08
RM27T0E _51 Engine / Hybrid System _053660 1GD-FTV ENGINE CONTROL _0260461 ECD SYSTEM(w/ Urea SCR System) U

1GD-FTV ENGINE CONTROL  ECD SYSTEM(w/ Urea SCR System)  FAIL-SAFE CHART  


FAIL-SAFE CHART


If any of the following DTCs are stored, the ECM enters fail-safe mode to allow the vehicle to be driven temporarily.

DTC No. Detection Item Fail-safe Operation Fail-safe Deactivation Condition
P0046 Turbocharger / Supercharger Boost Control Solenoid Circuit Range / Performance The engine power is limited. Engine switch off
P0047 Turbocharger/ Supercharger Boost Control "A" Circuit Low The engine power is limited. Engine switch off
P0048 Turbocharger/ Supercharger Boost Control "A" Circuit High The engine power is limited. Engine switch off
P007C Charge Air Cooler Temperature Sensor Circuit Low
·

The Intake Air Temp (Turbo) is fixed at 170°C.

·

The intercooler temperature feedback is stopped.


Pass condition detected
P007D Charge Air Cooler Temperature Sensor Circuit High
·

The Intake Air Temp (Turbo) is fixed at 170°C.

·

The intercooler temperature feedback is stopped.


Pass condition detected
P0087 Fuel Rail/System Pressure - Too Low The engine power is reduced by 90%.* Engine switch off
P0088 Fuel Rail/System Pressure - Too High The engine power is reduced by 90%.* Engine switch off
P0093 Fuel System Leak Detected - Large Leak
·

The engine power is limited.

·

PM forced regeneration is prohibited.


Pass condition detected
P0097 Intake Air Temperature Sensor 2 Circuit Low Bank 1 The Intake Air Temp B1S2 is fixed at a specified value. Pass condition detected
P0098 Intake Air Temperature Sensor 2 Circuit High Bank 1 The Intake Air Temp B1S2 is fixed at a specified value. Pass condition detected
P00BB Fuel Injector Insufficient Flow - Forced Limited Power The engine power is limited. Pass condition detected
P00E0 Charge Air Cooler Coolant Temperature Sensor Circuit Low
·

The Intercooler Coolant Temperature output is fixed at a specified value (the fixed value varies depending on conditions).

·

The target intake manifold absolute pressure is limited.


Pass condition detected
P00E1 Charge Air Cooler Coolant Temperature Sensor Circuit High
·

The Intercooler Coolant Temperature output is fixed at a specified value (the fixed value varies depending on conditions).

·

The target intake manifold absolute pressure is limited.


Pass condition detected
P0100 Mass Air Flow Circuit Malfunction The engine power is limited. Pass condition detected
P0101 Mass or Volume Air Flow Circuit The engine power is limited. Engine switch off
P0107 Manifold Absolute Pressure/Barometric Pressure Circuit Low Input The turbo pressure is fixed at a specified value. Pass condition detected
P0108 Manifold Absolute Pressure/Barometric Pressure Circuit High Input The turbo pressure is fixed at a specified value. Pass condition detected
P0112 Intake Air Temperature Circuit Low Input
·

The intake air temperature value is fixed.

·

The target intake manifold absolute pressure is limited.


Pass condition detected
P0113 Intake Air Temperature Circuit High Input
·

The intake air temperature value is fixed.

·

The target intake manifold absolute pressure is limited.


Pass condition detected
P0115 Engine Coolant Temperature Circuit
·

The engine coolant temperature sensor output is fixed at a specified value (the fixed value varies depending on conditions).

·

The target intake manifold absolute pressure is limited.


Pass condition detected
P0117 Engine Coolant Temperature Circuit Low Input
·

The engine coolant temperature sensor output is fixed at a specified value (the fixed value varies depending on conditions).

·

The target intake manifold absolute pressure is limited.


Pass condition detected
P0118 Engine Coolant Temperature Circuit High Input
·

The engine coolant temperature sensor output is fixed at a specified value (the fixed value varies depending on conditions).

·

The target intake manifold absolute pressure is limited.


Pass condition detected
P0122 Throttle/Pedal Position Sensor/Switch "A" Circuit Low Input The engine power is limited. Engine switch off
P0123 Throttle/Pedal Position Sensor/Switch "A" Circuit High Input The engine power is limited. Engine switch off
P0190 Fuel Rail Pressure Sensor Circuit
·

The main and sub circuits of the fuel pressure sensor are malfunctioning:

-

The engine power is reduced by 90%.*


·

The main or sub circuit of the fuel pressure sensor is malfunctioning:

-

The engine power is limited.



Engine switch off
P0191 Fuel Rail Pressure Sensor Circuit Range / Performance
·

The main and sub circuits of the fuel pressure sensor are malfunctioning:

-

The engine power is reduced by 90%.*


·

The main or sub circuit of the fuel pressure sensor is malfunctioning:

-

The engine power is limited.



Engine switch off
P0192 Fuel Rail Pressure Sensor Circuit Low Input
·

The main and sub circuits of the fuel pressure sensor are malfunctioning:

-

The engine power is reduced by 90%.*


·

The main or sub circuit of the fuel pressure sensor is malfunctioning:

-

The engine power is limited.



Engine switch off
P0193 Fuel Rail Pressure Sensor Circuit High Input
·

The main and sub circuits of the fuel pressure sensor are malfunctioning:

-

The engine power is reduced by 90%.*


·

The main or sub circuit of the fuel pressure sensor is malfunctioning:

-

The engine power is limited.



Engine switch off
P0201 Injector Circuit / Open - (Cylinder 1) The engine power is limited. Engine switch off to on (IG) or STA on
P0202 Injector Circuit / Open - (Cylinder 2) The engine power is limited. Engine switch off to on (IG) or STA on
P0203 Injector Circuit / Open - (Cylinder 3) The engine power is limited. Engine switch off to on (IG) or STA on
P0204 Injector Circuit / Open - (Cylinder 4) The engine power is limited. Engine switch off to on (IG) or STA on
P023A Charge Air Cooler Coolant Pump Control Circuit/Open The Intercooler Coolant Temperature is fixed at 120°C (only when an open circuit is detected). Pass condition detected
P023B Charge Air Cooler Coolant Pump Control Circuit Low Fully discharges the electric water pump assembly. Pass condition detected
P023C Charge Air Cooler Coolant Pump Control Circuit High Fully discharges the electric water pump assembly. Pass condition detected
P0299 Turbocharger / Supercharger Underboost The engine power is limited. Pass condition detected
P0335 Crankshaft Position Sensor "A" Circuit The engine power is limited. Pass condition detected
P0337 Crankshaft Position Sensor "A" Circuit Low Input The engine power is limited. Pass condition detected
P0338 Crankshaft Position Sensor "A" Circuit High Input The engine power is limited. Pass condition detected
P0339 Crankshaft Position Sensor "A" Circuit Intermittent The engine power is limited. Pass condition detected
P0340 Camshaft Position Sensor "A" Circuit (Bank 1 or Single Sensor) The engine power is limited. Pass condition detected
P0342 Camshaft Position Sensor "A" Circuit Low Input (Bank 1 or Single Sensor) The engine power is limited. Pass condition detected
P0343 Camshaft Position Sensor "A" Circuit High Input (Bank 1 or Single Sensor) The engine power is limited. Pass condition detected
P0400 Exhaust Gas Recirculation Flow PM forced regeneration is prohibited. Engine switch off
P0405 Exhaust Gas Recirculation Sensor "A" Circuit Low The engine power is limited. Engine switch off
P0406 Exhaust Gas Recirculation Sensor "A" Circuit High The engine power is limited. Engine switch off
P0420 Catalyst System Efficiency Below Threshold (Bank 1) PM forced regeneration is prohibited. Pass condition detected
P042E Exhaust Gas Recirculation "A" Control Stuck Open PM forced regeneration is prohibited. Engine switch off
P0488 Exhaust Gas Recirculation Throttle Position Control Range/Performance The engine power is limited. Engine switch off
P0489 Exhaust Gas Recirculation Control Circuit Low The engine power is limited. Engine switch off
P0490 Exhaust Gas Recirculation Control Circuit High The engine power is limited. Engine switch off
P0500 Vehicle Speed Sensor "A" The vehicle speed is fixed at 0 km/h (0 mph). Pass condition detected
P0545 Exhaust Gas Temperature Sensor Circuit Low (Bank 1 Sensor 1) PM forced regeneration is prohibited. Pass condition detected
P0546 Exhaust Gas Temperature Sensor Circuit High (Bank 1 Sensor 1) PM forced regeneration is prohibited. Pass condition detected
P0606 ECM / PCM Processor The engine is stalled. Pass condition detected
P060A Internal Control Module Monitoring Processor Performance The engine is stalled. Pass condition detected
P060B Internal Control Module A/D Processing Performance The engine power is limited. Pass condition detected
P060D Internal Control Module Accelerator Pedal Position Performance The engine power is limited. Pass condition detected
P0627 Fuel Pump Control Circuit / Open The engine power is limited. Pass condition detected
P062D No. 1 Fuel Injector Driver Circuit Performance The engine power is limited. Engine switch off
P1229 Fuel Pump System The engine power is limited. Engine switch off
P1251 Turbocharger / Supercharger Overboost Condition (Too High) The engine power is limited. Engine switch off
P1271 Fuel Regulator Circuit Malfunction (EDU Drive) The engine power is limited. Engine switch off
P1272 Fuel Pressure Regulator Malfunction The engine power is limited. Engine switch off
P2002 Diesel Particulate Filter Efficiency Below Threshold Bank 1 PM forced regeneration is prohibited. Pass condition detected
P2006 Intake Manifold Runner Control Stuck Closed (Bank 1) The engine power is limited. Engine switch off
P200C Diesel Particulate Filter Over Temperature Bank 1 PM forced regeneration is prohibited. Engine switch off
P200E Catalyst System Temperature Too High Bank 1 PM forced regeneration is prohibited. Engine switch off
P2032 Exhaust Gas Temperature Sensor Circuit Low (Bank 1 Sensor 2) PM forced regeneration is prohibited. Pass condition detected
P2033 Exhaust Gas Temperature Sensor Circuit High (Bank 1 Sensor 2) PM forced regeneration is prohibited. Pass condition detected
P2080 Exhaust Gas Temperature Sensor Circuit Range/Performance Bank 1 Sensor 1 PM forced regeneration is prohibited. Pass condition detected
P2084 Exhaust Gas Temperature Sensor Circuit Range/Performance Bank 1 Sensor 2 PM forced regeneration is prohibited. Pass condition detected
P20CD Open in Exhaust Aftertreatment Fuel Injector "A" Control Circuit
·

The engine power is reduced by 90%.*

·

PM forced regeneration is prohibited.


Pass condition detected
P20CF Exhaust Aftertreatment Fuel Injector "A" Stuck Open The engine power is reduced by 90%.* Pass condition detected
P2120 Throttle/Pedal Position Sensor/Switch "D" Circuit The engine power is limited. Engine switch off
P2121 Throttle/Pedal Position Sensor/Switch "D" Circuit Range/Performance The engine power is limited. Engine switch off
P2122 Throttle/Pedal Position Sensor/Switch "D" Circuit Low Input The engine power is limited. Engine switch off
P2123 Throttle/Pedal Position Sensor/Switch "D" Circuit High Input The engine power is limited. Engine switch off
P2125 Throttle/Pedal Position Sensor/Switch "E" Circuit The engine power is limited. Engine switch off
P2127 Throttle/Pedal Position Sensor/Switch "E" Circuit Low Input The engine power is limited. Engine switch off
P2128 Throttle/Pedal Position Sensor/Switch "E" Circuit High Input The engine power is limited. Engine switch off
P2138 Throttle/Pedal Position Sensor/Switch "D"/"E" Voltage Correlation The engine power is limited. Engine switch off
P2195 Oxygen (A/F) Sensor Signal Stuck Lean (Bank 1 Sensor 1) The power to the No. 1 nitrogen oxides sensor and No. 1 nitrogen oxides sensor heater is stopped. Pass condition detected
P2200 NOx Sensor Circuit Bank 1 Sensor 1 The power to the No. 1 nitrogen oxides sensor and No. 1 nitrogen oxides sensor heater is stopped. Pass condition detected
P220E NOx Sensor Heater Control Circuit Range/Performance Bank 1 Sensor 1 The power to the No. 1 nitrogen oxides sensor and No. 1 nitrogen oxides sensor heater is stopped. Pass condition detected
P2226 Barometric Pressure Circuit The atmospheric pressure is fixed at a specified value. Pass condition detected
P2228 Barometric Pressure Circuit Low Input The atmospheric pressure is fixed at a specified value. Pass condition detected
P2229 Barometric Pressure Circuit High Input The atmospheric pressure is fixed at a specified value. Pass condition detected
P225D NOx Sensor Performance - Signal Stuck Low Bank 1 Sensor 1 The power to the No. 1 nitrogen oxides sensor and No. 1 nitrogen oxides sensor heater is stopped. Pass condition detected
P2428 Exhaust Gas Temperature Too High Bank 1 PM forced regeneration is prohibited. Pass condition detected
P242B Exhaust Gas Temperature Sensor Circuit Range/Performance Bank 1 Sensor 3 PM forced regeneration is prohibited. Pass condition detected
P242C Exhaust Gas Temperature Sensor Circuit Low Bank 1 Sensor 3 PM forced regeneration is prohibited. Pass condition detected
P242D Exhaust Gas Temperature Sensor Circuit High Bank 1 Sensor 3 PM forced regeneration is prohibited. Pass condition detected
P244B Diesel Particulate Filter Differential Pressure Too High
·

The engine power is limited.

·

PM forced regeneration is prohibited.


Engine switch off
P2458 Diesel Particulate Filter Regeneration Duration PM forced regeneration is prohibited. Engine switch off
P2463 Diesel Particulate Filter Restriction - Soot Accumulation
·

The engine power is limited.

·

PM forced regeneration is prohibited.


Pass condition detected
P2564 Turbocharger/ Supercharger Boost Control Position Sensor "A" Circuit Low The engine power is limited. Engine switch off
P2565 Turbocharger/ Supercharger Boost Control Position Sensor "A" Circuit High The engine power is limited. Engine switch off

HINT:

*: Engine power is limited immediately after the DTC is stored.


Urea SCR System
DTC No. Detection Item Fail-safe Operation Fail-safe Deactivation Condition
P202B Reductant Tank Heater Control Circuit Low Urea SCR system is stopped. Pass condition detected
P202C Reductant Tank Heater Control Circuit High Urea SCR system is stopped. Pass condition detected
P202D Reductant Leakage Urea SCR system is stopped. Pass condition detected
P203C Reductant Level Sensor Circuit Low Urea SCR system is stopped. Pass condition detected
P203D Reductant Level Sensor Circuit High Urea SCR system is stopped. Pass condition detected
P203F Reductant Level Too Low Urea SCR system is stopped. Pass condition detected
P2048 Reductant Injector Circuit Low (Bank 1 Unit 1) Urea SCR system is stopped. Pass condition detected
P2049 Reductant Injector Circuit High (Bank 1 Unit 1) Urea SCR system is stopped. Pass condition detected
P204B Reductant Pressure Sensor Circuit Range/ Performance Urea SCR system is stopped. Pass condition detected
P204C Reductant Pressure Sensor Circuit Low Urea SCR system is stopped. Pass condition detected
P204D Reductant Pressure Sensor Circuit High Urea SCR system is stopped. Pass condition detected
P205B Reductant Tank Temperature Sensor Circuit Range/ Performance Urea SCR system is stopped. Pass condition detected
P205C Reductant Tank Temperature Sensor Circuit Low Urea SCR system is stopped. Pass condition detected
P205D Reductant Tank Temperature Sensor Circuit High Urea SCR system is stopped. Pass condition detected
P208B Reductant Pump "A" Control Range/ Performance Urea SCR system is stopped. Pass condition detected
P208D Reductant Pump "A" Control Circuit High Urea SCR system is stopped. Pass condition detected
P209F Reductant Tank Heater Control Circuit Performance Urea SCR system is stopped. Pass condition detected
P20BA Reductant Heater "A" Control Circuit Performance Urea SCR system is stopped. Pass condition detected
P20BB Reductant Heater "A" Control Circuit Low Urea SCR system is stopped. Pass condition detected
P20BC Reductant Heater "A" Control Circuit High Urea SCR system is stopped. Pass condition detected
P20E9 Reductant Pressure Too High Urea SCR system is stopped. Pass condition detected
P20EE SCR NOx Catalyst Efficiency Below Threshold Bank 1 Urea SCR system is stopped. Pass condition detected
P21C5 Reductant Level Sensor "A" Stuck Urea SCR system is stopped. Pass condition detected
U010E Lost Communication with Reductant Control Module Urea SCR system is stopped. Pass condition detected
U029D Lost Communication with NOx Sensor "A" Urea SCR system is stopped. Pass condition detected