Home › Engine / Hybrid System › 1GD-FTV (ENGINE CONTROL) › ECD SYSTEM (w/ Urea SCR System) › 2018.06–2020.08
RM27T0E _51 Engine / Hybrid System _053660 1GD-FTV ENGINE CONTROL _0260461 ECD SYSTEM(w/ Urea SCR System) U

1GD-FTV ENGINE CONTROL  ECD SYSTEM(w/ Urea SCR System)  DATA LIST / ACTIVE TEST  


DATA LIST


HINT:

Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.


NOTICE:

In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


a.

Warm up the engine.


b.

Turn the engine switch off.


c.

Connect the GTS to the DLC3.


d.

Turn the engine switch on (IG).


e.

Start the engine.


f.

Turn the GTS on.


g.

Enter the following menus: Powertrain / Engine and ECT / Data List.

HINT:
·

To display the list box, press the pull down menu button next to "Primary". Then select a measurement group.

·

When you select a measurement group, the ECU data belonging to that group is displayed.


·

Measurement Group List / Description

-

All Data / All data

-

Primary / -

-

Engine Control / Engine control system related data

-

Common Rail / Fuel system related data

-

Common Rail (ALL) / Fuel system related detailed data

-

Diesel EGR / EGR system related data

-

Diesel Throttle / Diesel throttle system related data

-

VN Turbo / VN turbo related data

-

Diesel Exhaust / Exhaust system related data

-

Diesel Starting / "Difficult to start" related data

-

Diesel Rough Idle / "Rough idle" related data

-

Diesel Lack of Power / "Lack of power" related data

-

Diesel Knocking / "Knocking" related data

-

Diesel Black Smoke / "Black smoke" related data

-

Monitor Status / Monitor status related data

-

Charging Control / Charging control system related data

-

Compression / Data used during "Check the Cylinder Compression" Active Test

-

A/T / Automatic transmission system related data

-

Vehicle Information / Vehicle information

-

Catalytic Converter / Catalytic Converter related data





h.

Check the values by referring to the table below.

NOTICE:

Normal Condition: If no idling conditions are specified, the shift lever should be in N, and the A/C switch and all accessory switches should be off.




Various Vehicle Conditions 1 (All Data)


Vehicle Speed
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Vehicle Speed Vehicle speed/
Min.: 0 km/h, Max.: 255 km/h
Actual vehicle speed Sensor output (speed sensor)
·

Speed sensor

·

Speed sensor circuit



Target Idle Engine Speed
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Target Idle Engine Speed Target Idling Engine Speed/
Min.: 0 rpm, Max.: 51199 rpm
- Target idling speed (ECM calculated value) -

Engine Speed
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Engine Speed Engine speed/
Min.: 0 rpm, Max.: 16384 rpm
·

50 to 400 rpm: Cranking

·

650 to 750 rpm: Idling with warm engine


Sensor output (crankshaft position sensor)
·

Crankshaft position sensor

·

Crankshaft position sensor circuit


Diagnostic Note:
When the crankshaft position sensor is malfunctioning, "Engine Speed" is approximately 0 or varies greatly from the actual engine speed.

Calculate Load
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Calculate Load Load calculated by ECM/
Min.: 0%, Max.: 100%
·

Idling: 6.6 to 16.5%

·

Running without load (3000 rpm): 15.5 to 27.0%


Calculated by ECM Malfunction in which turbo pressure or mass air flow decreases
Diagnostic Note:
Calculated load = (Final injection volume / max. injection volume at current engine speed) x 100.

MAF
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
MAF Air flow rate from mass air flow meter/
Min.: 0 gm/sec, Max.: 655 gm/sec
Idling:
·

0.5 to 15.0 gm/sec (EGR on)

·

10.0 to 21.0 gm/sec (EGR off)


Running without load (3000 rpm):
·

45.0 to 89.0 gm/sec (EGR on)

·

72.0 to 117.0 gm/sec (EGR off)


Sensor output (mass air flow meter)
·

Mass air flow meter sub-assembly

·

Mass air flow meter sub-assembly circuit

·

Intake related clog or leak

·

Exhaust related clog

·

Turbocharger sub-assembly

·

Leak or clog in passages for turbocharger

·

Malfunction in which EGR valve does not close


Symptoms when out of range:
Rough idling
Diagnostic Note:
·

Based on the MAF, the ECM controls the fuel injection volume, injection timing, EGR, etc.

·

When a judgment is difficult, turn off the EGR system and confirm this value.



Atmosphere Pressure
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Atmosphere Pressure Atmospheric pressure value/
Min.: 0 kPa, Max.: 255 kPa
Actual atmospheric pressure Sensor output (atmospheric pressure sensor (built into ECM)) Atmospheric pressure sensor itself has failed (atmospheric pressure sensor is inside the ECM)
Diagnostic Note:
·

With the engine switch on (IG), when the difference between the atmospheric pressure sensor and intake manifold absolute pressure is 10 kPa or more, there is a malfunction in one of the sensors.

·

With the engine switch on (IG), when the atmospheric pressure is 0 or 140 kPa, there is a malfunction in the sensor circuit.

·

Standard atmospheric pressure: 101 kPa.

·

For every 100 m increase in elevation, pressure drops by 1 kPa.

This varies by weather (high atmospheric pressure, low atmospheric pressure).



MAP
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
MAP Absolute pressure inside intake manifold/
Min.: 0 kPa, Max.: 320 kPa
Idling:
·

90 to 102 kPa (EGR on)

·

66 to 101 kPa (EGR off)


Running without load (3000 rpm):
·

110 to 160 kPa (EGR on)

·

102 to 153 kPa (EGR off)


Sensor output (manifold absolute pressure sensor)
·

Manifold absolute pressure sensor

·

Intake related clog or leak

·

Exhaust related clog

·

Turbocharger sub-assembly

·

Leak or clog in passages for turbocharger

·

EGR valve stuck open

·

Exhaust leak

·

Throttle valve stuck closed


Symptoms when out of range:
Lack of power
Diagnostic Note:
·

When the engine switch is on (IG) or the vehicle is idling, the intake manifold absolute pressure and atmospheric pressure are approximately the same (standard atmospheric pressure = 101 kPa).

Above approximately 1500 rpm, the turbo becomes effective and the pressure becomes higher than atmospheric pressure.

·

Inspect while comparing with "Target Booster Pressure".

·

With the accelerator fully open, if the actual manifold absolute pressure (MAP) is low compared to the target booster pressure by at least 20 kPa for 5 seconds or more, a feeling of insufficient power will occur.



Coolant Temp
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Coolant Temp Engine coolant temperature/
Min.: -40°C, Max.: 215°C
After warming up engine: 70 to 90°C (158 to 194°F) Sensor output (engine coolant temperature sensor)
·

Engine coolant temperature sensor

·

Thermostat


Symptoms when out of range:
Difficulty starting when engine is cold, rough idle, black smoke, lack of power
Diagnostic Note:
·

If the value is -40°C (-40°F) or 140°C (284°F), the sensor circuit is open or shorted.

·

After a long soak, the coolant temperature, intake air temperature and ambient temperature are approximately equal.



Intake Air
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Intake Air Intake air temp/
Min.: -40°C, Max.: 140°C
Equivalent to temperature at location of mass air flow meter Sensor output (intake air temperature sensor (built into mass air flow meter)) Intake air temperature sensor
Diagnostic Note:
·

After a long soak, the engine coolant temperature, intake air temperature and ambient temperature are approximately equal.

·

If the value is -40°C (-40°F) or 140°C (284°F), the sensor circuit is open or shorted.



Intake Air Temp (Turbo) Supported
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Intake Air Temp (Turbo) Supported Intake air temp (Turbo) supported/
Unsupp or Supp
- - -
Diagnostic Note:
·

Supp: The item is supported by the vehicle.

·

Unsupp: The monitor is not supported by the vehicle.



Intake Air Temp (Turbo)
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Intake Air Temp (Turbo) Intake air temp (Turbo)/
Min.: -40°C, Max.: 215°C
70°C (158°F) or less Sensor output (intake air temperature sensor (for intake air connector)) Decreased cooling efficiency of intercooler (contamination, clogging)
Diagnostic Note:
·

This is the intake air temperature at the intake air connector.

·

Displays the output value of the intake air temperature sensor (for intake air connector).

·

During fail-safe operation, the value is set to 165°C (329°F). As the value is set to a high temperature, the manifold absolute pressure may be suppressed and there may be a lack of power.



Intake Air Temp B1S1 Supported
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Intake Air Temp B1S1 Supported Intake air temp B1S1 supported/
Unsupp or Supp
Supp - -
Diagnostic Note:
·

Supp: The item is supported by the vehicle.

·

Unsupp: The monitor is not supported by the vehicle.



Intake Air Temp B1S1
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Intake Air Temp B1S1 Intake air temp B1S1/
Min.: -40°C, Max.: 215°C
Equivalent to temperature at location of mass air flow meter - -
Diagnostic Note:
Intake Air Temp B1S1 displays the output value of the intake air temperature sensor (built into mass air flow meter sub-assembly).

Intake Air Temp B1S2 Supported
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Intake Air Temp B1S2 Supported Intake air temp B1S2 supported/
Unsupp or Supp
Supp - -
Diagnostic Note:
·

Supp: The item is supported by the vehicle.

·

Unsupp: The monitor is not supported by the vehicle.



Intake Air Temp B1S2
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Intake Air Temp B1S2 Intake air temp B1S2/
Min.: -40°C, Max.: 215°C
Equivalent to ambient temperature around intercooler inlet - -
Diagnostic Note:
·

Intake air temperature before passing through the intercooler.

·

Displays the output value of the intake air temperature sensor (for intercooler).



Intake Air Temp B1S3 Supported
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Intake Air Temp B1S3 Supported Intake air temp B1S3 supported/
Unsupp or Supp
- - -
Diagnostic Note:
·

Supp: The item is supported by the vehicle.

·

Unsupp: The monitor is not supported by the vehicle.



Intake Air Temp B1S3
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Intake Air Temp B1S3 Intake air temp B1S3/
Min.: -40°C, Max.: 215°C
- - -

Intake Air Temp B2S1 Supported
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Intake Air Temp B2S1 Supported Intake air temp B2S1 supported/
Unsupp or Supp
- - -
Diagnostic Note:
·

Supp: The item is supported by the vehicle.

·

Unsupp: The monitor is not supported by the vehicle.



Intake Air Temp B2S1
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Intake Air Temp B2S1 Intake air temp B2S1/
Min.: -40°C, Max.: 215°C
- - -

Intake Air Temp B2S2 Supported
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Intake Air Temp B2S2 Supported Intake air temp B2S2 supported/
Unsupp or Supp
- - -
Diagnostic Note:
·

Supp: The item is supported by the vehicle.

·

Unsupp: The monitor is not supported by the vehicle.



Intake Air Temp B2S2
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Intake Air Temp B2S2 Intake air temp B2S2/
Min.: -40°C, Max.: 215°C
- - -

Intake Air Temp B2S3 Supported
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Intake Air Temp B2S3 Supported Intake air temp B2S3 supported/
Unsupp or Supp
- - -
Diagnostic Note:
·

Supp: The item is supported by the vehicle.

·

Unsupp: The monitor is not supported by the vehicle.



Intake Air Temp B2S3
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Intake Air Temp B2S3 Intake air temp B2S3/
Min.: -40°C, Max.: 215°C
- - -

Ambient Temperature
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Ambient Temperature Ambient Temperature/
Min.: -40°C, Max.: 215°C
Equivalent to ambient temperature - -
Diagnostic Note:
After a long soak, the engine coolant temperature, intake air temperature and ambient temperature are approximately equal.


Diesel Exhaust 1


NOx Density B1S1
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
NOx Density B1S1 NOx Density B1S1/
Min.: 0 ppm, Max.: 65535 ppm
0 to 1650 ppm - -
Diagnostic Note:
NOx Density B1S1 indicates the output value of the No. 1 nitrogen oxides sensor.

NOx Density B1S1 Supported
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
NOx Density B1S1 Supported NOx Density B1S1 Supported/
Unsupp or Supp
Supp - -
Diagnostic Note:
·

Supp: The item is supported by the vehicle.

·

Unsupp: The monitor is not supported by the vehicle.



NOx Density B1S2
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
NOx Density B1S2 NOx Density B1S2/
Min.: 0 ppm, Max.: 65535 ppm
0 to 1650 ppm - -
Diagnostic Note:
NOx Density B1S2 indicates the output value of the No. 2 nitrogen oxides sensor.

NOx Density B1S2 Supported
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
NOx Density B1S2 Supported NOx Density B1S2 Supported/
Unsupp or Supp
Supp - -
Diagnostic Note:
·

Supp: The item is supported by the vehicle.

·

Unsupp: The monitor is not supported by the vehicle.



NOx Density B2S1
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
NOx Density B2S1 NOx density B2S1/
Min.: 0 ppm, Max.: 65535 ppm
- - -

NOx Density B2S1 Supported
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
NOx Density B2S1 Supported NOx Density B2S1 Supported/
Unsupp or Supp
- - -
Diagnostic Note:
·

Supp: The item is supported by the vehicle.

·

Unsupp: The monitor is not supported by the vehicle.



NOx Density B2S2
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
NOx Density B2S2 NOx density B2S2/
Min.: 0 ppm, Max.: 65535 ppm
- - -

NOx Density B2S2 Supported
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
NOx Density B2S2 Supported NOx Density B2S2 Supported/
Unsupp or Supp
- - -
Diagnostic Note:
·

Supp: The item is supported by the vehicle.

·

Unsupp: The monitor is not supported by the vehicle.



NOx Corrected Density B1S1
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
NOx Corrected Density B1S1 NOx Corrected Density B1S1/
Min.: 0 ppm, Max.: 65535 ppm
0 to 1650 ppm - -
Diagnostic Note:
·

NOx Density B1S1 indicates the calibration value of the No. 1 nitrogen oxides sensor.

·

Use the value of this item for diagnosis.



NOx Corrected Density B1S1 Supported
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
NOx Corrected Density B1S1 Supported NOx Corrected Density B1S1 Supported/
Unsupp or Supp
Supp - -
Diagnostic Note:
·

Supp: The item is supported by the vehicle.

·

Unsupp: The monitor is not supported by the vehicle.



NOx Corrected Density B1S2
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
NOx Corrected Density B1S2 NOx Corrected Density B1S2/
Min.: 0 ppm, Max.: 65535 ppm
0 to 1650 ppm - -
Diagnostic Note:
·

NOx Density B1S2 indicates the calibration value of the No. 2 nitrogen oxides sensor.

·

Use the value of this item for diagnosis.



NOx Corrected Density B1S2 Supported
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
NOx Corrected Density B1S2 Supported NOx Corrected Density B1S2 Supported/
Unsupp or Supp
Supp - -
Diagnostic Note:
·

Supp: The item is supported by the vehicle.

·

Unsupp: The monitor is not supported by the vehicle.



NOx Corrected Density B2S1
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
NOx Corrected Density B2S1 NOx Corrected Density B2S1/
Min.: 0 ppm, Max.: 65535 ppm
- - -

NOx Corrected Density B2S1 Supported
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
NOx Corrected Density B2S1 Supported NOx Corrected Density B2S1 Supported/
Unsupp or Supp
- - -
Diagnostic Note:
·

Supp: The item is supported by the vehicle.

·

Unsupp: The monitor is not supported by the vehicle.



NOx Corrected Density B2S2
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
NOx Corrected Density B2S2 NOx Corrected Density B2S2/
Min.: 0 ppm, Max.: 65535 ppm
- - -

NOx Corrected Density B2S2 Supported
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
NOx Corrected Density B2S2 Supported NOx Corrected Density B2S2 Supported/
Unsupp or Supp
- - -
Diagnostic Note:
·

Supp: The item is supported by the vehicle.

·

Unsupp: The monitor is not supported by the vehicle.




Various Vehicle Conditions 2 (All Data)


Engine Run Time
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Engine Run Time Engine run time/
Min.: 0 sec., Max.: 65535 sec.
Time after the engine switch turned to on (IG) Result of ECU calculations (using the engine speed) -
Diagnostic Note:
Time passed since the engine switch was turned to on (IG).

Initial Engine Coolant Temp
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Initial Engine Coolant Temp Initial engine coolant temperature/
Min.: -40°C, Max.: 120°C
Engine coolant temperature when engine started Sensor output when engine started -
Diagnostic Note:
For freeze frame data, this tells whether the malfunction happened at a cold start or with a warm engine.

Initial Intake Air Temp
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Initial Intake Air Temp Initial intake air temperature/
Min.: -40°C, Max.: 120°C
Intake air temperature when engine started Sensor output when engine started -

Battery Voltage
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Battery Voltage Battery voltage/
Min.: 0 V, Max.: 66 V
11 to 14 V - -
Symptoms when out of range:
If 5 V or less, starting becomes difficult
Diagnostic Note:
If 11 V or less, characteristics of some electrical components change.

Alternate Duty Ratio
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Alternate Duty Ratio Alternator generation duty ratio/
Min.: 0%, Max.: 128%
·

No electrical load at idling:

20 to 60%


·

High electrical load at idling:

100%


-
·

Battery deterioration

·

Alternator malfunction

·

Electric load, lights, etc.


Diagnostic Note:
·

This is outputs the alternator generation duty and is used to determine the electrical load.

·

Can be used to determine whether a higher-than-normal injection volume at idle, etc. is due to electrical loading or from some other source. For example, when the duty is not high but the idling injection volume is high, there is injector volume degradation or high engine friction.

·

Can be used for judging whether or not a malfunctioning component in the electrical system is generating continual generation requests (e.g., battery deterioration is causing an unending full recharge request, etc.). Regardless of whether or not an auxiliary device like the A/C or heater is active, if the alternator duty is always at the maximum value, there is an electrical system abnormality, like battery deterioration.



Glow Relay Request
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Glow Relay Request Status of the glow relay request/
ON or OFF
- - -

Glow Control Unit Duty
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Glow Control Unit Duty Glow control unit duty/
Min.: 0%, Max.: 127.5%
- Result of ECU calculations -
Diagnostic Note:
This is the ECM command.

Glow Indicator Supported
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Glow Indicator Supported Glow Indicator Supported/
Unsupp or Supp
- - -
Diagnostic Note:
·

Supp: The item is supported by the vehicle.

·

Unsupp: The monitor is not supported by the vehicle.



Glow Indicator
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Glow Indicator Status of the glow indicator/
ON or OFF
- - -

Accel Position
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Accel Position Accelerator position status/
Min.: 0%, Max.: 100%
·

Accelerator pedal released:

0%

·

Accelerator pedal fully depressed:

100%


·

Accelerator pedal position sensor opening position

·

ECT requested opening position

·

Cruise requested opening position

·

VSC requested opening position


-
Diagnostic Note:
·

"Accel Position" is the accelerator opening amount (%) for engine control use.

·

When the accelerator pedal position sensor output itself (Accel Sens. No.1 Volt %, Accel Sens. No.2 Volt %) is in the normal voltage range, another actuator malfunction has caused the fail-safe function to restrict the accelerator.

·

Without cruise, ECT or VSC requests, and without accelerator restriction by the fail-safe function, this is adjusted in proportion to the amount the accelerator pedal is depressed by the driver.

·

Accelerator pedal released: 0%

·

Accelerator pedal fully depressed: 100%



Accel Sens. No.1 Volt %
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Accel Sens. No.1 Volt % Accelerator position No. 1/
Min.: 0%, Max.: 100%
·

Accelerator pedal released:

10 to 22%

·

Accelerator pedal fully depressed:

52 to 90%


Sensor output (Accelerator pedal position sensor) -
Diagnostic Note:
Read value with engine switch on (IG) (do not start engine).
HINT:

This is used only for diagnosing malfunctions in the accelerator pedal position sensor. Under normal conditions, it is sufficient to only check the final accelerator opening angle value "Accel Position".



Accel Sens. No.2 Volt %
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Accel Sens. No.2 Volt % Accelerator position No. 2/
Min.: 0%, Max.: 100%
·

Accelerator pedal released:

24 to 40%

·

Accelerator pedal fully depressed:

68 to 99%


Sensor output (Accelerator pedal position sensor) -
Diagnostic Note:
Read value with engine switch on (IG) (do not start engine).
HINT:

This is used only for diagnosing malfunctions in the accelerator pedal position sensor. Under normal conditions, it is sufficient to only check the final accelerator opening angle value "Accel Position".




Diesel Throttle System


Target Throttle Position Supported
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Target Throttle Position Supported Target Throttle Position Supported/
Unsupp or Supp
- - -
Diagnostic Note:
·

Supp: The item is supported by the vehicle.

·

Unsupp: The monitor is not supported by the vehicle.



Target Throttle Position
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Target Throttle Position Target throttle position/
Min.: 0%, Max.: 100%
·

Throttle valve fully closed: 0%

·

Throttle valve fully opened: 100%


Value calculated by ECM -
Diagnostic Note:
If there is a malfunction of the throttle actuator, compare the target and actual throttle position values for troubleshooting.

Target Throttle Position #2 Supported
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Target Throttle Position #2 Supported Target throttle position (No. 2) supported/
Unsupp or Supp
- - -
Diagnostic Note:
·

Supp: The item is supported by the vehicle.

·

Unsupp: The monitor is not supported by the vehicle.



Target Throttle Position #2
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Target Throttle Position #2 Target No. 2 throttle position/
Min.: 0%, Max.: 100%
- Value calculated by ECM -

Actual Throttle Position Supported
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Actual throttle position supported Actual throttle position supported/
Unsupp or Supp
- - -
Diagnostic Note:
·

Supp: The item is supported by the vehicle.

·

Unsupp: The monitor is not supported by the vehicle.



Actual Throttle Position
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Actual Throttle Position Actual diesel throttle position/
Min.: 0%, Max.: 100%
Idling after engine warmed-up: 0 to 92% - -
Symptoms when out of range:
·

Stuck closed: Engine stall, difficult to start, lack of power, black smoke, rough idle

·

Stuck open: Loud turbocharging sound, bad vibration when engine is stopped

·

When ECM detects a malfunction of the diesel throttle (MIL on), engine power is restricted so that the vehicle can drive with a maximum speed of 80 to 100 km/h.


Diagnostic Note:
Closing percentage of the throttle valve.
·

Fully closed: 0%.

·

Fully open: 100%.

HINT:

There is no connection with the accelerator. However, under full load, the throttle is usually fully open (100%).




Actual Throttle Position #2 Supported
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Actual Throttle Position #2 Supported Actual No. 2 throttle position supported/
Unsupp or Supp
- - -
Diagnostic Note:
·

Supp: The item is supported by the vehicle.

·

Unsupp: The monitor is not supported by the vehicle.



Actual Throttle Position #2
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Actual Throttle Position #2 Actual No. 2 diesel throttle position/
Min.: 0%, Max.: 100%
- - -

Throttle Motor Duty
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Throttle Motor Duty Throttle Motor Actuate DUTY #1/
Min.: 0%, Max.: 128%
0 to 80% - -
Diagnostic Note:
When the moving force to open and close the diesel throttle valve increases, the value of the Throttle Motor Duty increases.

Throttle Close Learning Val.
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Throttle Close Learning Val. Throttle fully closed position learned value/
Min.: 0 deg, Max.: 500 deg
14 to 22 deg - -
Diagnostic Note:
·

When the engine switch is turned from on (IG) to off and 5 seconds elapse, learning of "Throttle Close Learning Val." will be complete.

·

When "Throttle Close Learning Val." is outside of the normal range, a foreign object may be lodged in the throttle valve.

·

If the value is stuck at the upper limit of 21.25 deg, there is a chance that a malfunction is present.

However, as the initial value for the learned value is 21.25 deg, it is necessary to check the value after learning is completed.



Throttle Sensor Volt %
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Throttle Sensor Volt % Absolute throttle position sensor/
Min.: 0%, Max.: 100%
·

Engine switch on (IG): 60 to 100%

·

Warmed-up and idling: 8 to 100%


Sensor output (throttle position sensor) -
Symptoms when out of range:
·

Stuck closed: Engine stall, difficult to start, rough idling, lack of power, black smoke, white smoke

·

Stuck open: Loud turbocharging sound, bad vibration when engine is stopped

·

When the ECM detects a malfunction with the diesel throttle (MIL on), engine power is restricted but city driving is possible.


Diagnostic Note:
·

Throttle position sensor output voltage is converted using 5 V = 100%.

·

When fully closed: 20%.

·

When fully open: 82%.

·

When the engine switch is turned from off to on (IG), the throttle valve fully opens once.

·

When the engine switch is turned from on (IG) to off, the throttle valve fully closes once.



Throttle Motor Duty
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Throttle Motor Duty Throttle Motor Actuate DUTY/
Min.: 0%, Max.: 100%
- - -
Diagnostic Note:
When the moving force to open and close the diesel throttle valve increases, the value of the Throttle Motor Duty increases.


Diesel Injection System


Injection Volume
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Injection Volume Injection volume/
Min.: 0 mm3/st, Max.: 1279.98 mm3/st
Idling: 3 to 15 mm3/st Calculated value -
Diagnostic Note:
·

Injection amount for each combustion.

·

If injector assemblies are clogged fuel quality is poor, the fuel filter element assembly is clogged, or engine friction increases, "Injection Volume" will increase.

·

If there is a malfunction due to low turbocharger pressure or a low intake air volume, the injection volume is limited and there is a lack of power.



Inj. FB Vol. for Idle
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Inj. FB Vol. for Idle Idle stability status integral control volume/
Min.: -640 mm3/st, Max.: 640 mm3/st
-20 to 30 mm3/st - -
Symptoms when out of range:
Engine friction problem, compression problem or injector breakdown
Diagnostic Note:
·

When the actual engine speed does not match the target idling speed, this corrects the injection volume.

If this item displays 30 mm3/st or more or -20 mm3/st or less even with the engine completely warmed up and the air conditioning and other electrical loads off, the internal parts of the engine may be damaged, or the fuel injection system or other auxiliary components may be malfunctioning.

·

Only calculated and reflected at idle.



Inj Vol Feedback Learning
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Inj Vol Feedback Learning Injection volume feedback learning value/
Min.: -20 mm3/st, Max.: 20 mm3/st
- - -

Injection Feedback Val #1 / Injection Feedback Val #2 / Injection Feedback Val #3 / Injection Feedback Val #4
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Injection Feedback Val #1
Injection Feedback Val #2
Injection Feedback Val #3
Injection Feedback Val #4
Injection volume correction for each cylinder/
Min.: -20 mm3/st, Max.: 20 mm3/st
Idling: -3.0 to 3.0 mm3/st Learned value
·

Injector clogging

·

Injector deterioration

·

Decrease in cylinder compression

·

Injector compensation code is incorrectly set (forgot to input code after replacement or made mistake during setting of code after replacing ECM with one from another vehicle)


Symptoms when out of range:
Rough idling, black smoke, white smoke, poor driveability, lack of power, abnormal combustion noise, difficult to start
Diagnostic Note:
·

When idling after warmup, the injection amount for each cylinder is corrected to optimize the difference between the engine speed of each cylinder.

Example: For cylinders that are slowing the engine speed compared to other cylinders, the injection volume is increased.

·

"Injection Feedback Val" more than 3.0 mm3/st: Injector breakdown is causing injection volume deviation, or insufficient compression is causing poor combustion.

·

Even if "Injection Feedback Val" for a cylinder is less than -3.0 mm3/st, the cylinder with this value does not necessarily have a problem.

HINT:
·

The ECM adjusts each cylinder so that the average "Injection Feedback Val" of the 4 cylinders is approximately 0 mm3/st.

·

If more than one cylinder has a positive correction value, a normal cylinder may have a value less than -3.0 mm3/st.





Pre Injection Period
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Pre Injection Period Pre injection period/
Min.: 0 μs, Max.: 65535 μs
- Calculated value -

Pilot 1 Injection Period
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Pilot 1 Injection Period Pilot 1 injection period/
Min.: 0 μs, Max.: 65535 μs
Idling: 100 to 500 μs Calculated value -
Symptoms when out of range:
Combustion noise, poor driveability, white smoke
Diagnostic Note:
Check to see if "Pilot 1 Injection Period" is not zero when symptoms occur.

Pilot 2 Injection Period
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Pilot 2 Injection Period Pilot 2 injection period/
Min.: 0 μs, Max.: 65535 μs
Idling:
·

100 to 500μs (Atmospheric pressure higher than 85 kPa)

·

100 to 600μs (Atmospheric pressure 85 kPa or less)


Calculated value -
Symptoms when out of range:
Combustion noise, poor driveability, white smoke
Diagnostic Note:
Check to see if "Pilot 2 Injection Period" is not zero when symptoms occur.

Main Injection Period
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Main Injection Period Main injection period/
Min.: 0 μs, Max.: 65535 μs
Idling:
·

100 to 600μs (Atmospheric pressure higher than 85 kPa)

·

200 to 500μs (Atmospheric pressure 85 kPa or less)


Calculated value -
Diagnostic Note:
·

When the fuel pressure becomes 15000 kPa or less, "Main Injection Period" is set to 0.

·

When the engine will not start, confirm that injection is performed.

·

When P0093, P0627 or P062D is stored, there is an engine stall request. At that time, "Main Injection Period" equals 0.

HINT:

As the engine stalls 1 minute after the MIL illuminates, freeze frame data cannot be checked.




After Injection Period
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
After Injection Period After injection period/
Min.: 0 μs, Max.: 65535 μs
- Calculated value -
Diagnostic Note:
Check to see if "After Injection Period" is not zero when the following symptoms occur:
Black smoke, poor driveability.

Pre Injection Timing
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Pre Injection Timing Pre injection timing/
Min.: -210 deg(CA), Max.: 302 deg(CA)
- Calculated value -

Pilot 1 Injection Timing
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Pilot 1 Injection Timing Pilot 1 injection timing/
Min.: -210 deg(CA), Max.: 302 deg(CA)
Idling after engine warmed up and vehicle under normal atmospheric pressure: 13.0 to 9.0 deg(CA) Calculated value -

Pilot 2 Injection Timing
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Pilot 2 Injection Timing Pilot 2 injection timing/
Min.: -210 deg(CA), Max.: 302 deg(CA)
Idling after engine warmed up and vehicle under normal atmospheric pressure: 9.0 to 4.5 deg(CA) Calculated value -

Main Injection Timing
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Main Injection Timing Main injection timing/
Min.: -210 deg(CA), Max.: 302 deg(CA)
Idling after engine warmed up and vehicle under normal atmospheric pressure: 3.0 to -1.5 deg(CA) Calculated value -
Diagnostic Note:
Use "Main Injection Timing" to check poor drivability when the following symptoms are present: Bad injection timing, black smoke, and white smoke.

After Injection Timing
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
After Injection Timing After injection timing/
Min.: -210 deg(CA), Max.: 302 deg(CA)
- Calculated Value -

Pilot Quantity Learning
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Pilot Quantity Learning State of "Pilot Quantity Learning"/
Standby, Wait, Learn, Stop, Comple
- Calculated value -
Diagnostic Note:
·

The status is only displayed while performing "Pilot Quantity Learning".

·

If "Pilot Quantity Learning" is incomplete, the MIL illuminates and DTC P062F is stored.



Injector Pilot Quantity Learning
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Injector Pilot Quantity Learning Status of the injector pilot quantity learning/
Ready or NG
- - -

Actuator Pilot Quantity Learning
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Actuator Pilot Quantity Learning Status of the actuator pilot quantity learning/
Ready or NG
- - -

Temperature Pilot Quantity Learning
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Temperature Pilot Quantity Learning Status of the temperature pilot quantity learning/
Ready or NG
- - -

Catalyst Pilot Quantity Learning
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Catalyst Pilot Quantity Learning Status of the catalyst pilot quantity learning/
Ready or NG
- - -

Injection Pressure Correction
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Injection Pressure Correction Injection pressure feedback compensation volume/
Min.: -640 mm3/st, Max.: 640 mm3/st
-100 to 100 mm3/st at standard temperature Calculated value
·

Pre-stroke control valve malfunction

·

Clogged fuel filter element sub-assembly


Diagnostic Note:
·

When the (actual) fuel pressure is equal to the target fuel pressure, this value becomes 0.

·

This indicator can be used for diagnosing supply pump related malfunctions.

·

When this value (absolute value) is large, it indicates that the difference between the actual and target fuel pressure is also large.

·

A positive value indicates that the pressure feed is being increased due to insufficient pressure. A negative value indicates that pressure is being reduced due to excessive rail pressure.

·

When the pre-stroke control valve is malfunctioning, it causes rail overpressure, and this value slips to the negative volume side.

·

Injection Pressure Correction displays the value calculated by the ECM.



PCV Energization Timing
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
PCV Energization Timing Pre-stroke control valve energization timing
Min.: 0 deg(CA), Max.:639.9 deg(CA)
Idling: 0 to 180 deg(CA) - -
Diagnostic Note:
·

Displays the pre-stroke control valve energization timing.

·

When Common Rail Pressure is higher than Target Common Rail Pressure and the fuel supply pump assembly is not commanded to discharge, the value of PCV Energization Timing is -1.

·

When the fuel supply pump assembly is commanded to discharge, PCV Energization Timing changes to a value between 70 and 180. The larger the value, the smaller the amount of discharge.

·

PCV Energization Timing displays the value calculated by the ECM.



Target Common Rail Pressure Supported
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Target Common Rail Pressure Supported Target common rail pressure supported/
Unsupp or Supp
- Target common rail pressure (ECU calculated value) -
Diagnostic Note:
·

Supp: The item is supported by the vehicle.

·

Unsupp: The monitor is not supported by the vehicle.



Target Common Rail Pressure
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Target Common Rail Pressure Target common rail pressure/
Min.: 0 kPa(abs), Max.: 655350 kPa(abs)
20000 to 220000 kPa when engine running Target common rail pressure (ECU calculated value) -
Diagnostic Note:
·

Inspect the (actual) fuel pressure, comparing it with the common rail target value.

·

Considered normal when the actual fuel pressure is within 5000 kPa of the target fuel pressure under stable conditions when idling after warm up the engine.



Common Rail Pressure Supported
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Common Rail Pressure Supported Common rail pressure supported/
Unsupp or Supp
- Target common rail pressure (ECU calculated value) -
Diagnostic Note:
·

Supp: The item is supported by the vehicle.

·

Unsupp: The monitor is not supported by the vehicle.



Common Rail Pressure
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Common Rail Pressure Actual common rail pressure/
Min.: 0 kPa, Max.: 655350 kPa
Idling: 30000 to 50000 kPa Sensor output (fuel pressure sensor)
·

Fuel supply pump assembly

·

High pressure pipes

·

Fuel pressure sensor

·

Injector assembly

·

Feed pump (fuel supply pump assembly)

·

Fuel filter element sub-assembly

·

Pressure discharge valve

·

Air in the fuel pipes

·

Lack of fuel


Symptoms when out of range:
Difficult to start, poor driveability, lack of power, abnormal combustion noise
Diagnostic Note:
·

Common Rail Pressure is the actual common rail fuel pressure.

·

Inspect by comparing the fuel pressure with the target fuel pressure.

·

When in a stable condition such as when idling after warming up the engine, the fuel pressure is within 5000 kPa of the target fuel pressure.

·

The ECM uses fuel pressure for feedback control of the target fuel pressure via the fuel supply pump assembly.

The injection amount is determined based on the injection timing and fuel pressure. Also, the spray pattern is selected based on the fuel pressure.

·

For startup, at least 25000 kPa of fuel pressure is needed (take care as there is a response lag when the pressure rises).

·

When the fuel pressure is below 25000 kPa, it may cause rough idling.

·

When the fuel pressure has decreased by 20000 kPa from the target fuel pressure, there may be a lack of power.

·

If actual fuel pressure is 5000 kPa higher than the target fuel pressure, P1229 will be stored. When the actual fuel pressure is lower than the target fuel pressure, "P1608 Lack of Power" may be detected depending on the degree of deviation from the target pressure.

·

When the fuel pressure is higher than 240000 kPa, DTC P0088 will be stored.



Fuel Temperature Supported
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Fuel Temperature Supported Fuel temperature support/
Unsupp or Supp
Unsupp - -
Diagnostic Note:
·

Supp: The item is supported by the vehicle.

·

Unsupp: The monitor is not supported by the vehicle.



Fuel Temperature
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Fuel Temperature Fuel Temperature/
Min.: -40°C, Max.: 140°C
- - -

Fuel Return Temperature
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Fuel Return Temperature Fuel Return Temperature/
Min.: -40°C, Max.: 140°C
- Value calculated by ECM -

Injection Volume (Cylinder1)
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Injection Volume (Cylinder1) Injection Volume (Cylinder1)/
Min.: 0 ml, Max.: 2.047 ml
- - -
Diagnostic Note:
This is the injection volume for 10 injections.

Pressure Discharge Valve
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Pressure Discharge Valve Pressure discharge valve operation/
ON or OFF
ON: Pressure discharge valve open - -
Diagnostic Note:
This is the ECM command.

Pump Difference Angle Learning Value
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Pump Difference Angle Learning Value Supply pump difference angle learning value /
Min.: -1024 deg(CA), Max.: 1023.9 deg(CA)
- - -
Diagnostic Note:
·

Learns the installation difference angle of the fuel supply pump assembly on the engine.

·

When Pump Difference Angle Learning Value is below -3 deg(CA) or more than 3 deg(CA), check Target Common Rail Pressure and Common Rail Pressure.

·

Pump Difference Angle Learning Value displays the value calculated by the ECM.




Diesel Exhaust 2


AF Lambda B1S1
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
AF Lambda B1S1 Lambda equivalent ratio/
Min.: 0, Max.: 7.99
·

AF Lambda B1S1 = air-fuel ratio / 14.5 (Stoichiometric A/F ratio)

·

Value less than 1 (0.000 to 0.999): Rich

·

Value more than 1 (1.001 to 255): Lean

·

Air-fuel ratio = intake air mass / (main fuel injection and exhaust fuel addition injection mass)


-
·

No. 1 nitrogen oxides sensor

·

No. 1 nitrogen oxides sensor circuit

·

Injector assembly clogged


Diagnostic Note:
·

Check the No. 1 nitrogen oxides sensor output with the No. 2 exhaust gas temperature (Exhaust Temperature B1S2) at 200°C (392°F) or higher (example: driving at speed of 50 km/h (31 mph) or more in 3rd gear).

·

If the exhaust fuel addition injector is clogged, the AF Lambda B1S1 value changes according to engine combustion, but large changes due to the addition of fuel are not seen even when PM forced regeneration is performed with the GTS.

·

Furthermore, if the main injectors become clogged, the AF Lambda B1S1 value will increase under all circumstances while the engine is running (the value increases regardless of whether the PM forced regeneration has been performed).



AF Lambda B1S1 Supported
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
AF Lambda B1S1 Supported Status of the AF Lambda B1S1 Supported/
Unsupp or Supp
- - -
Diagnostic Note:
·

Supp: The item is supported by the vehicle.

·

Unsupp: The monitor is not supported by the vehicle.



AF Lambda B1S2
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
AF Lambda B1S2 Lambda equivalent ratio/
Min.: 0, Max.: 7.99
- - -
Diagnostic Note:
-

AF Lambda B1S2 Supported
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
AF Lambda B1S2 Supported Status of the AF Lambda B1S2 Supported/
Unsupp or Supp
- - -
Diagnostic Note:
·

Supp: The item is supported by the vehicle.

·

Unsupp: The monitor is not supported by the vehicle.



AF Lambda B2S1
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
AF Lambda B2S1 Lambda equivalent ratio/
Min.: 0, Max.: 7.99
- - -

AF Lambda B2S1 Supported
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
AF Lambda B2S1 Supported Status of the AF Lambda B2S1 Supported/
Unsupp or Supp
- - -
Diagnostic Note:
·

Supp: The item is supported by the vehicle.

·

Unsupp: The monitor is not supported by the vehicle.



AF Lambda B2S2
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
AF Lambda B2S2 Lambda equivalent ratio/
Min.: 0, Max.: 7.99
- - -

AF Lambda B2S2 Supported
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
AF Lambda B2S2 Supported Status of the AF Lambda B2S2 Supported/
Unsupp or Supp
- - -
Diagnostic Note:
·

Supp: The item is supported by the vehicle.

·

Unsupp: The monitor is not supported by the vehicle.



A/F (O2) Density B1S1
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
A/F (O2) Density B1S1 A/F (O2) Density B1S1/
0 to 100%
- - -

A/F (O2) Density B1S1 Supported
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
A/F (O2) Density B1S1 Supported Status of the A/F (O2) Density B1S1 Supported/
Unsupp or Supp
- - -
Diagnostic Note:
·

Supp: The item is supported by the vehicle.

·

Unsupp: The monitor is not supported by the vehicle.



A/F (O2) Density B1S2
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
A/F (O2) Density B1S2 A/F (O2) Density B1S2/
0 to 100%
- - -

A/F (O2) Density B1S2 Supported
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
A/F (O2) Density B1S2 Supported Status of the A/F (O2) Density B1S2 Supported/
Unsupp or Supp
- - -
Diagnostic Note:
·

Supp: The item is supported by the vehicle.

·

Unsupp: The monitor is not supported by the vehicle.



A/F (O2) Density B2S1
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
A/F (O2) Density B2S1 A/F (O2) Density B2S1/
0 to 100%
- - -

A/F (O2) Density B2S1 Supported
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
A/F (O2) Density B2S1 Supported Status of the A/F (O2) Density B2S1 Supported/
Unsupp or Supp
- - -
Diagnostic Note:
·

Supp: The item is supported by the vehicle.

·

Unsupp: The monitor is not supported by the vehicle.



A/F (O2) Density B2S2
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
A/F (O2) Density B2S2 A/F (O2) Density B2S2/
0 to 100%
- - -

A/F (O2) Density B2S2 Supported
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
A/F (O2) Density B2S2 Supported Status of the A/F (O2) Density B2S2 Supported/
Unsupp or Supp
- - -
Diagnostic Note:
·

Supp: The item is supported by the vehicle.

·

Unsupp: The monitor is not supported by the vehicle.



Intercooler Coolant Temperature
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Intercooler Coolant Temperature Intercooler Coolant Temperature/
Min.: -40°C, Max.: 215°C
Engine switch turned on (IG) : Equivalent to ambient temperature around intercooler coolant outlet - -

Intercooler Water Pump Duty Ratio
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Intercooler Water Pump Duty Ratio Intercooler Water Pump Duty Ratio/
Min.: 0%, Max.: 399.99%
30 to 85% : Electric water pump assembly running - -


EGR System


Target EGR Valve Pos Supported
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Target EGR Valve Pos Supported Target EGR valve pos supported/
Unsupp or Supp
- - -
Diagnostic Note:
·

Supp: The item is supported by the vehicle.

·

Unsupp: The monitor is not supported by the vehicle.



Target EGR Valve Pos
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Target EGR Valve Pos EGR valve target opening amount/
Min.: 0%, Max.: 100%
Idling after engine warmed up: 0 to 90% ECU-calculated value based on sensors (mass air flow meter, manifold absolute pressure sensor, intake air temperature (built into mass air flow meter), etc.) -
Symptoms when out of range:
·

When value is out of range and approaching 0%: mass air flow meter degradation, intake or exhaust system blockage

·

When value is out of range and approaching 100%: EGR pipe blockage


Diagnostic Note:
·

Fully closed: 0%.

·

Fully open: 100%.

·

Used for comparison to "Actual EGR Valve Pos.".



Target EGR Valve Pos #2 Supported
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Target EGR Valve Pos #2 Supported Target EGR valve pos #2 supported/
Unsupp or Supp
- - -
Diagnostic Note:
·

Supp: The item is supported by the vehicle.

·

Unsupp: The monitor is not supported by the vehicle.



Target EGR Valve Pos #2
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Target EGR Valve Pos #2 No. 2 EGR valve target opening amount/
Min.: 0%, Max.: 100%
- - -

Actual EGR Valve Pos Supported
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Actual EGR Valve Pos Supported Actual EGR valve pos supported/
Unsupp or Supp
- - -
Diagnostic Note:
·

Supp: The item is supported by the vehicle.

·

Unsupp: The monitor is not supported by the vehicle.



Actual EGR Valve Pos
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Actual EGR Valve Pos EGR valve position/
Min.: 0%, Max.: 100%
Idling after engine warmed up: 0 to 90% Calculated from EGR valve position sensor -
Symptoms when out of range:
·

EGR valve stuck open: Poor starts (engine does not stop), black smoke, white smoke, lack of power

·

EGR valve stuck closed: Increased turbo booster noise


Diagnostic Note:
·

Fully closed: 0%.

·

Fully open: 100%.

·

Inspect while comparing to "Target EGR Valve Pos".

·

Check the valve movement via the Active Test.

·

Sometimes malfunctions only occur around a certain temperature, so refer to the engine coolant temperature and outside temperature at the time the malfunction occurred.



EGR Rate Differential(Actual-Target)
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
EGR Rate Differential(Actual-Target) Difference between actual EGR and target EGR while idling/
Min.: -128%, Max.: 127%
- - -
Diagnostic Note:
·

Percentage value (-100 to 100%), calculated as (Actual EGR - Target EGR) * 100 is displayed.

·

The maximum value is retained once idling is stabilized. Once the vehicle is no longer idling, such as when the vehicle is accelerated, the value resets to 0%.

·

A positive value indicates a large amount of EGR and a negative value indicates asmall amount of EGR.



Actual EGR Valve Pos #2 Supported
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Actual EGR Valve Pos #2 Supported Actual EGR Valve Pos #2 Supported/
Unsupp or Supp
- - -
Diagnostic Note:
·

Supp: The item is supported by the vehicle.

·

Unsupp: The monitor is not supported by the vehicle.



Actual EGR Valve Pos #2
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Actual EGR Valve Pos #2 No. 2 EGR valve position/
Min.: 0%, Max.: 100%
- - -

EGR Position Sensor
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
EGR Position Sensor EGR Position Sensor/
Min.: 0 V, Max.: 4.999 V
- - -

EGR Motor Duty #1
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
EGR Motor Duty #1 EGR valve actuation duty:
Min.: 0%, Max.: 127.5%
Idling after engine warmed-up: 0 to 100% - -
Diagnostic Note:
·

To 0%: Close side EGR valve actuation.

·

To 100%: Open side EGR valve actuation.

·

When this value is large but the actual valve position does not reach the target valve position, there is an unable to open malfunction.



EGR Close Lrn. Val.
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
EGR Close Lrn. Val. EGR fully closed position learned value/
Min.: 0 V, Max.: 5 V
0 to 1 V EGR valve position sensor value when EGR valve fully closed -
Diagnostic Note:
·

This value is the EGR position sensor output voltage.

·

When the value is at the upper or lower limit of the normal range, it is possible that a foreign object is lodged in the EGR valve seat area.

·

As the lower and upper limits are 0 V and 1 V respectively, if the value becomes stuck at either of these values, there is a malfunction in the lift sensor or the valve position may be misaligned (foreign matter is present, etc.).



EGR Cooler Bypass VSV
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
EGR Cooler Bypass VSV Status of the No. 1 vacuum switching valve assembly (for EGR bypass valve)/
ON or OFF
·

ON: No. 1 vacuum switching valve assembly (for EGR Bypass Valve) is ON

·

OFF: No. 1 vacuum switching valve assembly (for EGR Bypass Valve) is OFF


-
·

No. 1 vacuum switching valve assembly (for EGR Bypass Valve)

·

No. 1 vacuum switching valve assembly (for EGR Bypass Valve) circuit


Diagnostic Note:
·

When No. 1 vacuum switching valve assembly (for EGR Bypass Valve) is ON, the value for EGR Cooler Bypass Position is Cooler and, when No. 1 vacuum switching valve assembly (for EGR Bypass Valve) is OFF, the value for EGR Cooler Bypass Position is Bypass.

·

The No. 1 vacuum switching valve assembly (for EGR Bypass Valve) is controlled by the ECM and the No. 1 vacuum switching valve assembly (for EGR Bypass Valve) is opened and closed by the vacuum created by the vacuum pump.



EGR Cooler Bypass Position
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
EGR Cooler Bypass Position Status of the EGR Cooler Bypass Position/
Cooler or Bypass
·

Cooler: No. 1 vacuum switching valve assembly (for EGR Bypass Valve) is "ON"

·

Bypass: No. 1 vacuum switching valve assembly (for EGR Bypass Valve) is "OFF"


-
·

No. 1 vacuum switching valve assembly (for EGR Bypass Valve)

·

No. 1 vacuum switching valve assembly (for EGR bypass valve) circuit


Diagnostic Note:
·

When No. 1 vacuum switching valve assembly (for EGR Bypass Valve) is ON, the value for EGR Cooler Bypass Position is Cooler and, when Vacuum Switching Valve Assembly (for EGR Bypass Valve) is OFF, the value for EGR Cooler Bypass Position is Bypass.

·

The No. 1 vacuum switching valve assembly (for EGR Bypass Valve) is controlled by the ECM and the No. 1 vacuum switching valve assembly (for EGR Bypass Valve) is opened and closed by the vacuum created by the vacuum pump.




VN Turbo System


Target Booster Pressure Supported
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Target Booster Pressure Supported Target booster pressure supported/
Unsupp or Supp
- - -
Diagnostic Note:
·

Supp: The item is supported by the vehicle.

·

Unsupp: The monitor is not supported by the vehicle.



Target Booster Pressure
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Target Booster Pressure Target booster pressure/
Min.: 0 kPa, Max.: 320 kPa
Driving vehicle on level surface at 3000 rpm with full load: 225 to 275 kPa Value calculated by ECM -
Diagnostic Note:
·

Inspect while comparing with "MAP".

·

With the accelerator fully open, if the actual manifold absolute pressure (MAP) is low compared to the target booster pressure by at least 20 kPa for 5 sec. or more, a feeling of a lack of power will occur.

·

When the vehicle is driven with the engine speed at 3000 rpm or more and the accelerator pedal fully depressed, "MAP" is approximately equal to "Target Booster Pressure".



Target VN Turbo Position Supported
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Target VN Turbo Position Supported Status of the Target VN Turbo Position Supported/
Unsupp or Supp
- - -
Diagnostic Note:
·

Supp: The item is supported by the vehicle.

·

Unsupp: The monitor is not supported by the vehicle.



Target VN Turbo Position
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Target VN Turbo Position Target VN turbo position/
Min.: 0%, Max.: 100%
0 to 96% - -
Diagnostic Note:
HINT:
·

When the nozzle vanes are fully closed (boost is applied), the value is 0%.

·

When the nozzle vanes are fully opened (boost is not applied), the value is 100%.




Target VN Turbo Position #2 Supported
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Target VN Turbo Position #2 Supported Status of the Target VN Turbo Position #2 Supported/
Unsupp or Supp
- - -
Diagnostic Note:
·

Supp: The item is supported by the vehicle.

·

Unsupp: The monitor is not supported by the vehicle.



Target VN Turbo Position #2
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Target VN Turbo Position #2 Target No. 2 VN turbo position/
Min.: 0%, Max.: 100%
- - -

Actual VN Position Supported
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Actual VN Position Supported Status of the Actual VN Position Supported/
Unsupp or Supp
- - -
Diagnostic Note:
·

Supp: The item is supported by the vehicle.

·

Unsupp: The monitor is not supported by the vehicle.



Actual VN Turbo Position
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Actual VN Turbo Position Actual VN turbo position/
Min.: 0%, Max.: 100%
0 to 96% - -
Diagnostic Note:
·

When the nozzle vane gets stuck or the movement is abnormal, the difference between this value and Target VN Turbo Position increases and the VN turbo motor output (duty) also increases.

·

Actual VN Turbo Position is controlled to match Target VN Turbo Position.



Actual VN Position #2 Supported
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Actual VN Position #2 Supported Actual VN position #2 supported/
Unsupp or Supp
- - -
Diagnostic Note:
·

Supp: The item is supported by the vehicle.

·

Unsupp: The monitor is not supported by the vehicle.



Actual VN Turbo Position #2
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Actual VN Turbo Position #2 Actual No. 2 VN turbo position/
Min.: 0%, Max.: 100%
- - -

VN Position Sensor Out
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
VN Position Sensor Out VN position sensor output voltage/
Min.: 0 V, Max.: 5 V
Idling after engine warmed-up: 1 to 4.5 V - -
Diagnostic Note:
VN Position Sensor Out displays the opening angle of the nozzle vane output by the sensor.

VN Motor Duty
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
VN Motor Duty VN turbo motor duty/
Min.: 0%, Max.: 127.5%
2 to 88% - -
Diagnostic Note:
If the vanes do not move smoothly, the duty will increase towards 100%.

VN Close Learn Value
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
VN Close Learn Value VN turbo fully closed position learned value/
Min.: 0 V, Max.: 5 V
1 to 4.5 V - -

VN Turbo Type
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
VN Turbo Type VN turbo type/
Not Avl, Commo, Vacuum, CAN Com, DC
DC - -
Diagnostic Note:
Indicates the VN turbo vane actuation method.
·

DC motor system.

·

Negative-pressure diaphragm system.

·

Step motor system.



VN Turbo Max Angle
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
VN Turbo Max Angle VN turbo maximum opening amount/
Min.: 0%, Max.: 127.5%
- - -
Diagnostic Note:
·

The maximum vane opening amount is displayed in %.

·

The VN turbo is operated between VN Turbo Max Angle and VN Turbo Min Angle when the Test the Turbo Charger Step Motor Active Test is performed.



VN Turbo Min Angle
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
VN Turbo Min Angle VN turbo minimum opening amount/
Min.: 0%, Max.: 127.5%
- - -
Diagnostic Note:
·

The minimum vane opening amount is displayed in %.

·

The VN turbo is operated between VN Turbo Max Angle and VN Turbo Min Angle when the Test the Turbo Charger Step Motor Active Test is performed.




Diesel Exhaust 3


Exhaust Temperature B1S1 Supported
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Exhaust Temperature B1S1 Supported Exhaust Temperature B1S1 Supported/
Unsupp or Supp
- - -
Diagnostic Note:
·

Supp: The item is supported by the vehicle.

·

Unsupp: The monitor is not supported by the vehicle.



Exhaust Temperature B1S1
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Exhaust Temperature B1S1 Exhaust gas temperature of DOC catalyst/
Min.: -40°C, Max.: 6513.5°C
·

Idling after engine warmed-up: 50 to 400°C (122 to 752°F)

·

During PM forced regeneration: 50 to 450°C (122 to 842°F)


Sensor output (Exhaust gas temperature sensor)
·

Exhaust gas temperature sensor

·

DPF catalyst deteriorated


Diagnostic Note:
·

If an open occurs in an exhaust gas temperature sensor circuit, 0°C (32°F) is displayed on the GTS.

·

If a short occurs in an exhaust gas temperature sensor circuit, 1000°C (1832°F) is displayed on the GTS.



Exhaust Temperature B1S2 Supported
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Exhaust Temperature B1S2 Supported Exhaust Temperature B1S2 Supported/
Unsupp or Supp
- - -
Diagnostic Note:
·

Supp: The item is supported by the vehicle.

·

Unsupp: The monitor is not supported by the vehicle.



Exhaust Temperature B1S2
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Exhaust Temperature B1S2 Exhaust gas temperature of DPF catalyst/
Min.: -40°C, Max.: 6513.5°C
·

Idling after engine warmed-up: 50 to 400°C (122 to 752°F)

·

During PM forced regeneration: 500 to 700°C (932 to 1292°F)


Sensor output (No. 2 exhaust gas temperature sensor)
·

No. 2 exhaust gas temperature sensor

·

DPF catalyst deteriorated


Diagnostic Note:
·

If an open occurs in an No. 2 exhaust gas temperature sensor circuit, 0°C (32°F) is displayed on the GTS.

·

If a short occurs in an No. 2 exhaust gas temperature sensor circuit, 1000°C (1832°F) is displayed on the GTS.



Exhaust Temperature B1S3 Supported
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Exhaust Temperature B1S3 Supported Exhaust Temperature B1S3 Supported/
Unsupp or Supp
- - -
Diagnostic Note:
·

Supp: The item is supported by the vehicle.

·

Unsupp: The monitor is not supported by the vehicle.



Exhaust Temperature B1S3
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Exhaust Temperature B1S3 Exhaust gas temperature of DPF catalyst/
Min.: -40°C, Max.: 6513.5°C
·

Idling after engine warmed-up: 50 to 400°C (122 to 752°F)

·

During PM forced regeneration: 500 to 700°C (932 to 1292°F)


Sensor output (No. 3 exhaust gas temperature sensor)
·

No. 3 exhaust gas temperature sensor

·

DPF catalyst deteriorated


Diagnostic Note:
·

If an open occurs in an No. 3 exhaust gas temperature sensor circuit, 0°C (32°F) is displayed on the GTS.

·

If a short occurs in an No. 3 exhaust gas temperature sensor circuit, 1000°C (1832°F) is displayed on the GTS.



Exhaust Temperature B1S4 Supported
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Exhaust Temperature B1S4 Supported Exhaust Temperature B1S4 Supported/
Unsupp or Supp
- - -
Diagnostic Note:
·

Supp: The item is supported by the vehicle.

·

Unsupp: The monitor is not supported by the vehicle.



Exhaust Temperature B1S4
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Exhaust Temperature B1S4 Exhaust gas temperature of SCR catalyst/
Min.: -40°C, Max.: 6513.5°C
50 to 700°C (122 to 1292°F) Sensor output (No. 4 exhaust gas temperature sensor)
·

No. 4 exhaust gas temperature sensor

·

SCR catalyst deteriorated


Diagnostic Note:
·

If an open occurs in an No. 4 exhaust gas temperature sensor circuit, 0°C (32°F) is displayed on the GTS.

·

If a short occurs in an No. 4 exhaust gas temperature sensor circuit, 1000°C (1832°F) is displayed on the GTS.



Particulate Filter Differential Pressure Supported
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Particulate Filter Differential Pressure Supported Particulate Filter Differential Pressure Supported/
Unsupp or Supp
- - -
Diagnostic Note:
If this item displays "Unsupp", a fixed value is displayed for "Exhaust Temperature", as exhaust gas temperature sensors are not equipped on the vehicle.

Particulate Filter Differential Pressure
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Particulate Filter Differential Pressure Particulate Filter Differential Pressure/
Min.: -327.68 kPa, Max.: 327.67 kPa
Engine switch on (IG):
Approximately 0 kPa
Sensor output (DPF differential pressure sensor)
·

DPF catalyst

·

DPF differential pressure sensor

·

Vacuum pipe clogged

·

Differential pressure sensor air hose clogged


Diagnostic Note:
·

When PM (Particulate Matter) builds up in the DPF catalyst, the "DPF Differential Pressure" value increases.

·

At 3000 rpm (no load), if Catalyst Differential Press is more than 0.27, the DPF catalyst has become blocked.



Catalyst Differential Press
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Catalyst Differential Press Amount of clogging in catalyst/
Min.: -32.768, Max.: 32.767
0.27 or less Calculated value -
Symptoms when out of range:
·

If the difference in pressure increases, a decrease in engine power may be felt.

·

If an abnormal difference in pressure is detected, engine power is limited to protect the engine and catalyst.


Diagnostic Note:
·

Diagnosis is possible when the MAF reading is between 30 and 140 gm/sec.

·

When the air intake volume is very low, such as when idling, due to excessive pressure fluctuation the correct values will not be displayed.

·

Catalyst Differential Press is the DPF Differential Pressure corrected in response to the MAF and other values.

·

If the filter in the DPF catalyst is clogged, the "Catalyst Differential Press" value increases.

·

When the difference in pressure exceeds approximately 0.27, DTC P244B is stored.



Diff. Press. Sensor Corr.
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Diff. Press. Sensor Corr. Differential pressure sensor 0 point learned value/
Min.: -327.68 kPa, Max.: 327.67 kPa
engine switch on (IG) (engine stopped): - 1.5 to 1.5 kPa - Differential pressure sensor
Diagnostic Note:
·

This number indicates the correction value (0 point calibration) for compensation of variance in the differential pressure sensor.

·

If the value of DPF Differential Pressure does not approach 0 kPa when the engine switch is on (IG) (engine is stopped) and the Diff. Press. Sensor Corr. displays less than -1.5 kPa, or higher than 1.5 kPa, there may be a malfunction in the differential pressure sensor.

·

Note that the output of the differential pressure sensor fluctuates depending on the temperature.



Exhaust Fuel Addition Injector Status
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Exhaust Fuel Addition Injector Status Status of the exhaust fuel addition injector/
ON or OFF
ON: Exhaust fuel addition injector open - -

Exhaust Fuel Addition FB
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Exhaust FuelAddition FB Exhaust fuel addition correction value/
Min.: -327.68, Max.: 327.67
0.86 to 1.45 - Differential pressure sensor
·

Exhaust fuel addition injector assembly clogged

·

Exhaust manifold converter sub-assembly (DPF catalyst) deteriorated


Diagnostic Note:
·

Usually Exhaust Fuel Addition FB is between 0.86 and 1.45.

·

Exhaust Fuel Addition FB is a correction value to increase the fuel volume injected from the exhaust fuel addition injector assembly when the catalyst temperature does not rise to the target range during PM forced regeneration.

·

If the correction value is more than 1.45, a clog in the exhaust fuel addition injector assembly or fuel filter element assembly may be causing a reduction in injection volume or a problem with the engine (injector assemblies, EGR, etc.) where the exhaust gas temperature decreases may be present. As a result, the catalyst temperature does not rise properly causing the catalyst to deteriorate.



DPNR/DPF Status Reju(PM)
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
DPNR/DPF Status Reju(PM) Status of the DPF Status Reju (PM)/
Compl, Operate, Ready or Standby
During PM forced regeneration: Operate - -
Diagnostic Note:
The status is only displayed while performing "Activate the DPF Rejuvenate (PM)".
·

Standby

Before entering "Activate the DPF Rejuvenate (PM)".



·

Ready

Enabling condition for "Activate the DPF Rejuvenate (PM)" is not met.



·

Operate

PM forced regeneration is being performed.

If "Activate the DPF Rejuvenate (PM)" does not finish completely, the status turns to Ready.

If "Activate the DPF Rejuvenate (PM)" finishes completely, the status turns to Compl.



·

Compl

PM forced regeneration is completed.




PM Accumulation Ratio
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
PM Accumulation Ratio PM accumulation ratio/
Min.: 0%, Max.: 510%
- - -
Diagnostic Note:
·

When PM forced regeneration is necessary, 100% is displayed for PM Accumulation Ratio.

·

If the ratio exceeds 100%, PM forced regeneration will be performed automatically.




Various Vehicle Conditions 3 (All Data)


Starter Signal
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Starter Signal Starter signal/
ON or OFF
ON: Cranking -
·

OFF malfunction (engine switch (STA) is ON but the signal is OFF and the starter is operating): Wire harness is open or shorted to ground

·

ON malfunction (engine switch (STA) is off but the signal is ON and the starter is not operating): Wire harness is shorted to +B

·

Operation malfunction: engine switch malfunction, starter relay malfunction, starter malfunction, battery or battery cable is defective, or wire harness is open or shorted


Symptoms when out of range:
·

Engine switch on (IG) but the starter does not operate: Starting is not possible

·

Engine switch is off but the starter continues to operate: STA signal malfunction (P0617) is stored


Diagnostic Note:
Engine switch (STA) output:
·

ON: Starter is operating

·

OFF: Starter is not operating



Power Steering Signal
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Power Steering Signal Power steering switch signal/
ON or OFF
- - -

Neutral Position SW Signal
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Neutral Position SW Signal Park/neutral position switch status/
ON or OFF
ON: Shift lever in neutral Switch output (Park/neutral position switch status) -

Clutch Switch
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Clutch Switch Clutch switch/
ON or OFF
ON: Clutch pedal depressed Switch output (Clutch switch assembly for cruise control system) -
Symptoms when out of range:
The cruise control, pilot quantity learning, etc. may not function properly or may not function at all.
Diagnostic Note:
When this item displays "OFF" with the clutch pedal depressed, the shock when accelerating and decelerating the vehicle becomes larger and pilot quality learning cannot be performed.

Transfer L4
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Transfer L4 L4 status of the transfer/
ON or OFF
ON: L4 detection switch in L4 position - -

Stop Light Switch
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Stop Light Switch Stop light switch/
ON or OFF
·

ON: Brake pedal depressed

·

OFF: Brake pedal released


Switch output (stop light switch)
·

OFF malfunction: Wire harness (stop light switch to ECM, stop light switch to +B) open or shorted to ground

·

ON malfunction: Wire harness (stop light switch to ECM) shorted to +B

·

Stop light switch


Symptoms when out of range:
Stop light switch malfunction DTC P0504 or P0724 is stored
Diagnostic Note:
Stop light switch (STP) operation condition:
·

ON: Light is on (Brake pedal is depressed)

·

OFF: Light is off (Brake pedal is released)



Shift Indication Enable
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Shift Indication Enable Status of the Shift Indication Enable/
ON or OFF
- - -

A/C Signal
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
A/C Signal A/C (Air Conditioner) signal/
ON or OFF
ON: A/C on A/C operation signal output from A/C amplifier
·

ON: Operating

·

OFF: Not operating


·

A/C switch

·

A/C amplifier

·

A/C system malfunction, wire harness between A/C amplifier and ECU open or shorted


Symptoms when out of range:
OFF malfunction (OFF even when A/C switch is turned on):
Engine speed decreases temporarily when the A/C is operating.

Immobiliser Communication
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Immobiliser Communication Immobiliser communication/
ON or OFF
·

ON: Normal

·

OFF: Engine cannot be started due to immobiliser communication malfunction


-
·

Use of a non-registered key

·

Key battery is fully depleted



Clogged Fuel Filter Switch
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Clogged Fuel Filter Switch Status of the clogged fuel filter switch/
ON or OFF
- - Switch turns on when the fuel filter is clogged.


Check Mode (Check Mode)


Check Mode
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Check Mode Check mode/
ON or OFF
ON: Check mode on - -
Diagnostic Note:
Check Mode: The mode in which certain DTCs can be detected more easily and with higher sensitivity.

Test Result
Tester Display Measurement Item/Range Normal Condition Diagnostic Note
SPD Test Result Check mode result for vehicle speed sensor/
Compl or Incmpl
- *1
Exhaust Temperature B1S1 Test Result Check mode result for exhaust temperature B1S1/
Compl or Incmpl
- *1
Exhaust Temperature B1S2 Test Result Check mode result for exhaust temperature B1S2/
Compl or Incmpl
- *1
Exhaust Temperature B1S3 Test Result Check mode result for exhaust temperature B1S3/
Compl or Incmpl
- *1
Exhaust Temperature B1S4 Test Result Check mode result for exhaust temperature B1S4/
Compl or Incmpl
- *1
*1:
Incmpl / Compl: The item changes from Incmpl to Compl if the monitor was completed at least once at some time in the past. This item does not change when the engine switch is turned off. However, the item changes back to Incmpl when DTCs are cleared or the battery cable is disconnected.


Monitor Result/Stet result


Monitor Information
Tester Display Measurement Item/Range Normal Condition Diagnostic Note
Complete Parts Monitor Comprehensive component monitor/
Not Avl or Avail
- *1
Fuel System Monitor Fuel system monitor/
Not Avl or Avail
- *1
Misfire Monitor Misfire monitor/
Not Avl or Avail
- *1
EGR/VVT Monitor EGR/VVT monitor
Not Avl or Avail/
- *1
EGR/VVT Monitor EGR/VVT monitor
Compl or Incmpl
- *1
O2S(A/FS) Heater Monitor O2S(A/FS) heater monitor/
Not Avl or Avail
- *1
O2S(A/FS) Heater Monitor O2S(A/FS) heater monitor/
Compl or Incmpl
- *1
O2S(A/FS) Monitor O2S(A/FS) monitor/
Not Avl or Avail
- *1
O2S(A/FS) Monitor O2S(A/FS) monitor/
Compl or Incmpl
- *1
A/C Monitor A/C monitor/
Not Avl or Avail
- *1
A/C Monitor A/C monitor/
Compl or Incmpl
- *1
2nd Air Monitor 2nd air monitor/
Not Avl or Avail
- *1
2nd Air Monitor 2nd air monitor/
Compl or Incmpl
- *1
EVAP Monitor EVAP monitor/
Not Avl or Avail
- *1
EVAP Monitor EVAP monitor/
Compl or Incmpl
- *1
Heated Catalyst Monitor Heated catalyst monitor/
Not Avl or Avail
- *1
Heated Catalyst Monitor Heated catalyst monitor/
Compl or Incmpl
- *1
Catalyst Monitor Catalyst monitor/
Not Avl or Avail
- *1
Catalyst Monitor Catalyst monitor/
Compl or Incmpl
- *1
*1:
Avail: The monitor is available on the vehicle.
Not Avl: The monitor is not available on the vehicle.
Incmpl / Compl: The item changes from Incmpl to Compl if the monitor was completed at least once at some time in the past. This item does not change when the engine switch is turned off. However, the item changes back to Incmpl when DTCs are cleared or the battery cable is disconnected.


Various Vehicle Conditions 4 (All Data)


TC Terminal
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
TC Terminal TC terminal status/
ON or OFF
- - -

# Codes (Include History)
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
# Codes (Include History) Number of codes/
Min.: 0, Max.: 255
- - -
Diagnostic Note:
Number of DTCs appearing at least once during the last 40 times the vehicle was warmed up.

MIL
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
MIL MIL status/
ON or OFF
OFF: MIL off - -

MIL ON Run Distance
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
MIL ON Run Distance Distance traveled with MIL on/
Min.: 0 km, Max.: 65535 km
Distance traveled after DTC stored Result of ECU calculations (using the vehicle speed) -
Diagnostic Note:
·

Distance traveled after a DTC is stored.

·

Cleared when the cable is disconnected from the negative (-) battery terminal, or when the DTC is cleared using the GTS.



Running Time from MIL ON
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Running Time from MIL ON Running time after MIL turns on/
Min.: 0 min., Max.: 65535 min.
Running time after MIL turns on - -
Diagnostic Note:
·

Engine run time since the MIL illumination.

·

Cleared when the cable is disconnected from the negative (-) battery terminal, or when the DTC is cleared using the GTS.



Time after DTC Cleared
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Time after DTC Cleared Time after DTC cleared/
Min.: 0 min., Max.: 65535 min.
Time after DTCs cleared - -
Diagnostic Note:
Time elapsed since the DTCs were cleared (or shipment from the factory).

Distance from DTC Cleared
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Distance from DTC Cleared Distance driven after DTC cleared/
Min.: 0 km, Max.: 65535 km
Distance driven after DTCs cleared - -
Diagnostic Note:
·

Distance driven since the DTCs were cleared.

·

(Data List "Distance from DTC clear") - (Freeze frame data "Distance from DTC cleared") = Distance driven since the abnormality occurred.



Warmup Cycle Cleared DTC
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Warmup Cycle Cleared DTC Warmup cycles after DTC cleared/
Min.: 0, Max.: 255
- - -
Diagnostic Note:
·

Number of engine warmup since DTCs were cleared.

·

(Data List "Warmup Cycle Cleared DTC") - (Freeze frame data "Warmup Cycle Cleared DTC") = Warmup cycles since the abnormality occurred.



Dist Batt Cable Disconnect
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Dist Batt Cable Disconnect Distance driven after battery cable disconnected/
Min.: 0 km, Max.: 65535 km
- - -

IG OFF Elapsed Time
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
IG OFF Elapsed Time Time after engine switch turned off/
Min.: 0 min, Max.: 655350 min
Cumulative time after engine switch turned off - -

OBD Requirements
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
OBD Requirements Identifying OBD requirement - - -
Diagnostic Note:
Euro-OBD

Number of Emission DTC
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Number of Emission DTC Number of emissions-related DTCs - - -

TC and TE1
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
TC and TE1 TC and CG (TE1) terminals of DLC3/
ON or OFF
- - -
Diagnostic Note:
When the "Connect the TC and TE1" Active Test is performed, the system behaves as if TC and CG were connected.

Total Distance Traveled
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Total Distance Traveled Total distance traveled/
Min.: 0 km (0 mile), Max.: 16777215 km (10425361 mile)
Total distance vehicle driven after battery cable disconnected. - -


Diesel Starting


Engine Speed (Starter Off)
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Engine Speed (Starter Off) Engine speed when starter off/
Min.: 0 rpm, Max.: 51199 rpm
- - -
Diagnostic Note:
Engine speed immediately after starting the engine.

Starter Count
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Starter Count Starter on count/
Min.: 0, Max.: 255
- - -
Diagnostic Note:
Number of times the starter turned on from the time the engine switch was turned to on (IG).

Run Dist of Previous Trip
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Run Dist of Previous Trip Distance driven during previous trip/
Min.: 0 km, Max.: 655.35 km
- - -
Diagnostic Note:
Before 5 seconds elapse after starting the engine, which is the DTC P1604 (Startability Malfunction) detection duration, this parameter indicates the distance driven during the previous trip. After 5 seconds elapse after starting the engine, this parameter indicates the distance driven during the current trip calculated from the vehicle speed signal.
HINT:
·

Run Dist of Previous Trip in the freeze frame data present when the startability malfunction occurred (DTC P1604 detected) indicates the distance driven during the previous trip, but in all other cases, such as for the snapshot data of the Data List (real-time measurements), or for freeze frame data present when DTCs other than P1604 were detected, the value indicates the distance driven during the current trip.

·

If DTCs indicating insufficient power or problems with the DPF system, diesel throttle or EGR valve are stored, confirm this item in the freeze frame data of the stored DTCs to determine the distance driven when the DTCs were stored. The distance driven can be used as a reference when troubleshooting.




Glow Request Lighting Time
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Glow Request Lighting Time Glow request lighting time/
Min.: 0 ms, Max.: 25500 ms
- - -
Diagnostic Note:
·

By comparing Glow Request Lighting Time to IG-ON Time, the operation state (whether the engine was started, etc.) can be determined.

·

If the malfunction occurred when starting a cold engine at 0°C (32°F) or less, this item is useful in determining whether the engine was started after the glow plug indicator lights turned off.



IG-ON Time
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
IG-ON Time IG-ON time/
Min.: 0 ms, Max.: 25500 ms
- - -
Diagnostic Note:
·

By comparing Glow Request Lighting Time to IG-ON Time, the operation state (whether the engine was started, etc.) can be determined.

·

If the malfunction occurred when starting a cold engine at 0°C (32°F) or less, this item is useful in determining whether the engine was started after the glow plug indicator lights turned off.




Diesel Lack of Power


MAF Low
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
MAF Low Mass air flow Low/
ON or OFF
OFF -
·

Mass air flow meter sub-assembly (value is out of range)

·

Intake system blockage

·

Disconnected air hoses (intake system)

·

EGR system (EGR valve closing malfunction)

·

Nozzle vane (turbo) movement problems


Symptoms when out of range:
Lack of power
Diagnostic Note:
·

When DTC P1608 is output, this item indicates whether the cause of lack of power is related to the intake air amount.

·

This item indicates whether the intake air amount measured by the mass air flow meter sub-assembly was insufficient, which would cause the fuel injection volume to be reduced for a certain period of time. If this is the case, this item displays "ON" and DTC P1608 (lack of engine power) is stored.

·

This item is "ON" when the intake air amount is low due to blockage in the intake system, disconnection of hoses or an excessive amount of EGR, and also when the intake air amount is measured to be low due to deterioration of the mass air flow meter sub-assembly.



Boost Pressure Low
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Boost Pressure Low Status of the Boost Pressure Low/
ON or OFF
OFF -
·

Nozzle vane (turbo) stuck

·

Disconnected air hoses (intake system)

·

Manifold absolute pressure sensor

·

Atmospheric pressure sensor (built into ECM)

·

Difference between atmospheric pressure and intake pressure


Symptoms when out of range:
Lack of power
Diagnostic Note:
·

When DTC P1608 is output, this item indicates whether the cause of lack of power is due to the boost pressure.

·

This item indicates whether the actual boost pressure was insufficient compared to the target boost pressure, which would cause the fuel injection volume to be reduced for a certain period of time. If this is the case, this item displays "ON" and DTC P1608 (lack of engine power) is stored.



Common Rail Pressure Low
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Common Rail Pressure Low Status of the common rail pressure low/
ON or OFF
OFF -
·

Suction control valve (movement problems)

·

Fuel leak

·

Fuel pressure sensor (built into common rail assembly)


Symptoms when out of range:
Lack of power
Diagnostic Note:
·

When DTC P1608 is output, this item indicates whether the cause of lack of power is the common rail pressure.

·

This item indicates whether the actual common rail pressure was lower than the target pressure for a certain period of time. If this is the case, this item displays "ON" and DTC P1608 (lack of engine power) is stored.



Engine Coolant Temp High
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Engine Coolant Temp High Status of the engine coolant temp high/
ON or OFF
OFF -
·

Engine coolant temperature sensor

·

Engine coolant leak

·

Radiator clog


Symptoms when out of range:
Lack of power
Diagnostic Note:
·

When DTC P1608 is output, this item indicates whether the cause of lack of power is due to a high engine coolant temperature.

·

This item indicates whether the fuel injection volume was reduced for a certain period of time due to a high engine coolant temperature (overheating). If this is the case, this item displays "ON" and DTC P1608 (lack of engine power) is stored.



MAF/Estimate MAF Ratio
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
MAF/Estimate MAF Ratio Ratio of intake air amount to estimated intake air amount/
Min.: 0, Max.: 2.55
Engine speed 4000 rpm, EGR system off:
0.6 to 1.4
-
·

Mass air flow meter sub-assembly

·

Turbocharger sub-assembly

·

Pipes between turbocharger sub-assembly and intake manifold are disconnected or leaking

·

Pipes between mass air flow meter sub-assembly and turbocharger sub-assembly are disconnected or leaking


Symptoms when out of range:
Lack of power
Diagnostic Note:
·

Even when the system is normal, the value may deviate from the range specified in Normal Condition for a short period of time (approximately 1 second).

·

This item indicates the ratio of the intake air amount to the estimated intake air amount. The estimated air amount is calculated using the intake manifold pressure and intake air temperature.

·

When DTC P1608 is stored, this item is useful in determining whether there is a problem in the turbocharger system or a disconnected or leaking pipe in the high pressure intake system when the boost pressure is insufficient.

·

When performing troubleshooting, this information is only valid when there is a high load (the diesel throttle is fully open) and the EGR system is off.




Diesel Rough Idle


Compression Leakage Count
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Compression Leakage Count Compression leakage count/
Min.: 0, Max.: 255
0 - -
Diagnostic Note:
When the counter displays 1 or higher during an engine stall, startability malfunction or rough idle, it may be the result of pressure loss caused by deposits jamming the valve, etc.

Plural Cylinders Rough Idle
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Plural Cylinders Rough Idle Status of the plural cylinders rough idle/
ON or OFF
OFF - -
Diagnostic Note:
Indicates multiple cylinders are the cause of rough idling when ON.

Rough Idle #1 / Rough Idle #2 / Rough Idle #3 / Rough Idle #4
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Rough Idle #1
Rough Idle #2
Rough Idle #3
Rough Idle #4
Status of the rough idle #1 to #4/
ON or OFF
OFF - Injector assembly
Diagnostic Note:
·

This item indicates cylinders which had speeds lower than the other cylinders.

·

This item indicates cylinders which are likely to be the cause of rough idle.



Electric Duty Feedback Value
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Electric Duty Feedback Value Electric load feedback value/
Min.: 0 mm3/st, Max.: 39.8 mm3/st
0 to 5.8 mm3/st - -
Diagnostic Note:
Expected injection volume increase after the electrical load turns from off to on.

A/C Duty Feedback Value
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
A/C Duty Feedback Value A/C load feedback value/
Min.: 0 mm3/st, Max.: 39.8 mm3/st
0 to 3.3 mm3/st - -
Diagnostic Note:
Expected injection volume increase after the A/C turns from off to on.

PS Duty Feedback Value
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
PS Duty Feedback Value Power steering load feedback value/
Min.: 0 mm3/st, Max.: 39.8 mm3/st
0 mm3/st - -
Diagnostic Note:
Expected injection volume increase after the power steering turns from off to on.

Idle Injection Volume (Min)
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Idle Injection Volume (Min) Idle minimum injection volume/
Min.: 0 mm3/st, Max.: 39.8 mm3/st
- - -


Various Vehicle Conditions 5 (All Data)


Engine Starting Time
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Engine Starting Time Engine starting time/
Min.: 0 ms, Max.: 655350 ms
- - -
Diagnostic Note:
This is the time elapsed after the starter turns on until the engine speed reaches 400 rpm.
This value is cleared 5 seconds after the engine is started and the value is displayed as 0 ms.

Minimum Engine Speed
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Minimum Engine Speed Minimum engine speed/
Min.: 0 rpm, Max.: 51199 rpm
- - -

Alternator Output Duty
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Alternator Output Duty Alternator Output Duty/
Min.: 0%, Max.: 399.9%
- - -

Alt Vol - Non Active Test
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Alt Vol - Non Active Test Alternator Voltage - Non-Active Test/
Min.: 0 V, Max.: 79.998 V
- - -

Alt Vol - Active Test
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Alt Vol - Active Test Alternator Voltage - Active Test/
Min.: 0 V, Max.: 79.998 V
- - -

Previous Trip Alternator Max Output Time
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Previous Trip Alternator Max Output Time Previous Trip Alternator Max Output Time/
Min.: 0 sec, Max.: 65535 sec
- - -

Initial Engine Battery Minimum Voltage
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Initial Engine Battery Minimum Voltage Lowest battery voltage at start up/
Min.: 0 V, Max.: 25.5 V
- - -

ACM Inhibit
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
ACM Inhibit Status of vacuum switching valve assembly (for engine mounting)/
ON or OFF
ON: Vacuum switching valve assembly (for engine mounting) is ON - -

Swirl Control Valve VSV
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Swirl Control Valve VSV Status of vacuum switching valve assembly (for swirl control valve)/
ON or OFF
ON: Vacuum switching valve assembly (for swirl control valve) is ON - -

ACT VSV
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
ACT VSV A/C cut status/
ON or OFF
- - -

Electric Fan Motor
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Electric Fan Motor Electric fan motor/
ON or OFF
ON: Electric fan motor operation - -
Diagnostic Note:
-

Brake Override System
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Brake Override System Brake override system status/
ON or OFF
ON: Brake override system operating - -

Electric Cooling Fan High
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Electric Cooling Fan High Status of the Electric Cooling Fan High/
ON or OFF
ON: Electric fan motor operation - -
Diagnostic Note:
-

Electric Cooling Fan Low
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Electric Cooling Fan Low Status of the Electric Cooling Fan Low/
ON or OFF
ON: Electric fan motor operation - -
Diagnostic Note:
-

Immobiliser Fuel Cut History
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Immobiliser Fuel Cut History Immobiliser fuel cut history/
ON or OFF
OFF - -
Diagnostic Note:
If Immobiliser Fuel Cut History was "ON" when DTC P1604 (Startability Malfunction) was stored, the engine could not be started due to the immobiliser.


Diesel Exhaust 4


Comm with Reductant Control Module
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Comm with Reductant Control Module Status of the comm with urea pump control ECU/
No Comm or Comm
- - -
Diagnostic Note:
-


Vehicle Information


Model Code
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Model Code Model code - - -
Diagnostic Note:
Identifying model code: GDJ##

Engine Type
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Engine Type Engine type - - -
Diagnostic Note:
Identifying engine type: 1GDFTV

Cylinder Number
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Cylinder Number Cylinder number/
Min.: 0, Max.: 255
- - -
Diagnostic Note:
Identifying cylinder number: 4

Transmission Type
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Transmission Type Status of the Transmission Type/ - - -
Diagnostic Note:
Used for identifying transmission type:
·

MT: Manual transmission

·

ECT 6th: Automatic transmission



Destination
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Destination Destination - - -
Diagnostic Note:
Identifying destination

Model Year
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Model Year Model year/
Min.: 1900, Max.: 2155
- - -
Diagnostic Note:
Identifying model year: 20##

System Identification
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
System Identification System Identification/
-
- - -
Diagnostic Note:
Used for identifying the engine system


Compression


Engine Speed of Cyl #1
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Engine Speed of Cyl #1 Engine speed for No. 1 cylinder/
Min.: 0 rpm, Max.: 51199 rpm
Engine speeds of all cylinders almost same - Cyl #1 compression goes down
Symptoms when out of range:
When the engine speeds of all cylinders are not equal, idling will be rough.
Diagnostic Note:
·

Output only when the "Check the Cylinder Compression" Active Test is performed.

·

Indicates the speed of each cylinder when cranking.

Example - Normal: Engine speeds of all cylinders are approximately equal.

When No. 1 cylinder compression is low, "Engine Speed of Cyl #1" is approximately 300 rpm, and "Engine Speed of Cyl #2 to #4" is approximately 200 rpm.



Engine Speed of Cyl #2 to #4
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Engine Speed of Cyl #2 to #4 Engine speed for No. 2 to No. 4 cylinder/
Min.: 0 rpm, Max.: 51199 rpm
- - -

Av Engine Speed of All Cyl
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Av Engine Speed of All Cyl Engine speed for all cylinders/
Min.: 0 rpm, Max.: 51199 rpm
- - -
Diagnostic Note:
·

Output only when the Active Test "Check the Cylinder Compression" is performed.

·

Indicates the average engine speed of all cylinders during cranking.




Automatic Transmission (All Data)


Shift SW Status (P Range)
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Shift SW Status (P Range) Park/Neutral position switch status/
ON or OFF
·

ON: Shift lever in P

·

OFF: Shift lever not in P


- -
Diagnostic Note:
When the shift lever position displayed on the GTS differs from the actual position, adjustment of the park/neutral position switch or the shift cable may be incorrect.

Shift SW Status (R Range)
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Shift SW Status (R Range) Park/Neutral position switch status/
ON or OFF
·

ON: Shift lever in R

·

OFF: Shift lever not in R


- -
Diagnostic Note:
When the shift lever position displayed on the GTS differs from the actual position, adjustment of the park/neutral position switch or the shift cable may be incorrect.

Shift SW Status (N Range)
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Shift SW Status (N Range) Park/Neutral position switch status/
ON or OFF
·

ON: Shift lever in N

·

OFF: Shift lever not in N


- -
Diagnostic Note:
When the shift lever position displayed on the GTS differs from the actual position, adjustment of the park/neutral position switch or the shift cable may be incorrect.

Shift SW Status (D Range)
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Shift SW Status (D Range) Park/Neutral position switch status/
ON or OFF
·

ON: Shift lever in D

·

OFF: Shift lever not in D


- -
Diagnostic Note:
When the shift lever position displayed on the GTS differs from the actual position, adjustment of the park/neutral position switch or the shift cable may be incorrect.


Diesel Exhaust 5


Fr-NOx Sensor Active Status
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Fr-NOx Sensor Active Status Status of the Fr-NOx Sensor Active Status/
ON or OFF
- - -
Diagnostic Note:
Turns ON when the No. 1 nitrogen oxides sensor meets or exceeds a set temperature and becomes capable of stable output.

Reductant Level
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Reductant Level Reductant level/
Min.: 0, Max.: 255
- - -
Diagnostic Note:
Outputs the position of the urea solution inside the urea tank sub-assembly as a level from 0 to 6.

Reductant Temperature
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Reductant Temperature Reductant temperature/
Min.: -40°C, Max.: 215°C
- - -
Diagnostic Note:
Outputs the temperature of the urea solution inside the urea tank sub-assembly.

Reductant Pressure
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Reductant Pressure Reductant pressure/
Min.: -3276.8 kPa, Max.: 3276.7 kPa
-50 to 600 kPa - -
Diagnostic Note:
Outputs the pressure inside the urea pipe connecting the urea tank sub-assembly and urea injector set.

Reductant Pump Speed
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Reductant Pump Speed Urea pump speed/
Min.: 0 rpm, Max.: 65535 rpm
0 to 3000 rpm - -
Diagnostic Note:
Outputs the urea pump speed.

Reductant Injection Mode
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Reductant Injection Mode Reductant injection mode/
- or Mode3
- - -
Diagnostic Note:
Outputs the urea injector injection control mode.

Reductant Injection Value
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Reductant Injection Value Reductant injection value/
Min.: 0 g/h, Max.: 3276.75 g/h
0 to 1800 g/h - -
Diagnostic Note:
Outputs the urea solution injection volume.

Reductant Replenishment Possible Value
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Reductant Replenishment Possible Value Reductant Replenishment Possible Value/
Min.: 0 L, Max.: 65.535 L
- - -
Diagnostic Note:
Outputs the amount of urea solution that can be refilled.

Engine Exhaust NOx Density
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Engine Exhaust NOx Density Engine exhaust NOx density/
Min.: 0 ppm, Max.: 65535 ppm
0 to 1650 ppm - -
Diagnostic Note:
Outputs the concentration of NOx expelled from the engine.

SCR Temperature
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
SCR Temperature Exhaust gas temperature of SCR catalyst/
Min.: -40, Max.: 6513.5°C
50 to 630°C (122 to 1166°F) - -
Diagnostic Note:
Outputs the temperature at the center of the SCR catalyst.

Catalyst Thermal Degradation Count
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Catalyst Thermal Degradation Count Catalyst thermal degradation count/
Min.: 0, Max.: 4294967295
- - -
Diagnostic Note:
The count increases when the catalyst (DPF) temperature exceeds 500°C. The count is reset by the "DPR Deterioration History Initialization" item in the Utility menu.

Reductant Injection Value Restraint Control
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Reductant Injection Value Restraint Control Reductant injection value restraint control/
ON or OFF
- - -
Diagnostic Note:
Turns ON when the necessary urea solution injection volume is high and the quantity of urea consumption does not meet the target value. (Urea solution injection volume restraint is performed.)

SCR NOx Purge High Efficiency Temp
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
SCR NOx Purge High Efficiency Temp SCR NOx purge high efficiency temp/
ON or OFF
- - -
Diagnostic Note:
Turns ON when the SCR catalyst reaches a temperature that allows the Urea SCR system to demonstrate high NOx purification efficiency.

NOx Sensor Active Status
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
NOx Sensor Active Status NOx Sensor Active Status/
ON or OFF
- - -
Diagnostic Note:
Turns ON when the No. 2 nitrogen oxides sensor meets or exceeds a set temperature and becomes capable of stable output.

Reductant Tank Heater
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Reductant Tank Heater Urea tank heater status/
ON or OFF
- - -
Diagnostic Note:
Outputs the operation status of the urea tank heater.

Reductant Pipe Heater
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Reductant Pipe Heater Urea tube with heater assembly heater status/
ON or OFF
- - -
Diagnostic Note:
Outputs the operation status of the Urea tube with heater assembly.

NOx Sensor Cooling Time
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
NOx Sensor Cooling Time NOx sensor cooling time/
Min.: 0 sec, Max.: 65535 sec
- - -
Diagnostic Note:
Outputs the amount of time that has elapsed since the No. 2 nitrogen oxides sensor heater turned OFF.

Fr-NOx Sensor Cooling Time
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Fr-NOx Sensor Cooling Time Fr-NOx Sensor Cooling Time/
Min.: 0 sec, Max.: 65535 sec
- - -
Diagnostic Note:
Outputs the amount of time that has elapsed since the No. 1 nitrogen oxides sensor heater turned OFF.

NOx Sensor Carrying Request
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
NOx Sensor Carrying Request Status of the NOx Sensor Carrying Request/
ON or OFF
- - -
Diagnostic Note:
Outputs the power supply command for the No. 2 nitrogen oxides sensor.

Fr-NOx Sensor Carrying Request
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Fr-NOx Sensor Carrying Request Status of the Fr-NOx Sensor Carrying Request/
ON or OFF
- - -
Diagnostic Note:
Outputs the power supply command for the No. 1 nitrogen oxides sensor.

PM Sensor Heater Duty
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
PM Sensor Heater Duty PM Sensor Heater Duty/
Min.: 0%, Max.: 127.5%
- - -
Diagnostic Note:
Outputs the heater power supply DUTY value for the particulate matter sensor.

PM Sensor Power Supply Voltage
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
PM Sensor Power Supply Voltage PM Sensor Power Supply Voltage/
Min.: 0 V, Max.: 25.5 V
- - -
Diagnostic Note:
Outputs the power supply voltage value for the particulate matter sensor SCU.

PM Sensor Output Current
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
PM Sensor Output Current PM Sensor Output Current/
Min.: 0 μA, Max.: 127.5 μA
- - -
Diagnostic Note:
·

Outputs the output current value for the particulate matter sensor SCU.

·

Changes according to the PM volume in the exhaust gas.



PM Sensor Maximum Current Value
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
PM Sensor Maximum Current Value PM Sensor Maximum Current Value/
Min.: 0 μA, Max.: 127.5 μA
- - -
Diagnostic Note:
Outputs the maximum output current value for the particulate matter sensor SCU.

PM Sensor Element Temperature
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
PM Sensor Element Temperature PM Sensor Element Temperature/
Min.: -40°C, Max.: 119.3°C
- - -
Diagnostic Note:
Outputs the particulate matter sensor element temperature

Status of PM Sensor IDE Circuit Diagnosis
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Status of PM Sensor IDE Circuit Diagnosis Status of PM Sensor IDE Circuit Diagnosis/
Diagnosis Not Tested or Diagnosis Tested
- - -
Diagnostic Note:
Indicates the diagnosis status of the particulate matter sensor IDE circuit.

Status of PM Sensor IDE Circuit
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Status of PM Sensor IDE Circuit Status of PM Sensor IDE Circuit/
No Error Detected or Error Detected
- - -
Diagnostic Note:
·

Indicates the malfunction status of the particulate matter sensor IDE circuit.

·

Outputs P24AF when a malfunction occurs (tool display).



Status of PM Sensor IDE Diagnosis
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Status of PM Sensor IDE Diagnosis Status of PM Sensor IDE Diagnosis/
Diagnosis Not Tested or Diagnosis Tested
- - -
Diagnostic Note:
Indicates the diagnosis status of the particulate matter sensor IDE circuit.

Status of PM Sensor IDE
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Status of PM Sensor IDE Status of PM Sensor IDE/
No Error Detected or Error Detected
- - -
Diagnostic Note:
Indicates the malfunction status of the particulate matter sensor IDE.

Status of PM Sensor Heater Diagnosis
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Status of PM Sensor Heater Diagnosis Status of PM Sensor Heater Diagnosis/
Diagnosis Not Tested or Diagnosis Tested
- - -
Diagnostic Note:
Indicates the diagnosis status of the particulate matter sensor heater.

Status of PM Sensor Heater
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Status of PM Sensor Heater Status of PM Sensor Heater/
No Error Detected or Error Detected
- - -
Diagnostic Note:
Indicates the malfunction status of the particulate matter sensor heater.

Status of PM Sensor IDE (+ Side)
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Status of PM Sensor IDE (+ Side) Status of PM Sensor IDE (+ Side)/
No Error Detected or Error Detected
- - -
Diagnostic Note:
Outputs P24B0 when a malfunction occurs (tool display).
·

Indicates the malfunction status of the particulate matter sensor IDE (+Side).

·

Outputs P24B0 when a malfunction occurs (tool display).



Status of PM Sensor IDE Diagnosis (+ Side)
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Status of PM Sensor IDE Diagnosis (+ Side) Status of PM Sensor IDE Diagnosis (+ Side)/
Diagnosis Not Tested or Diagnosis Tested
- - -
Diagnostic Note:
Indicates the diagnosis status of the particulate matter sensor IDE (+Side).

Status of PM Sensor Rejuvenate Finish
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Status of PM Sensor Rejuvenate Finish Status of PM Sensor Rejuvenate Finish/
ON or OFF
- - -
Diagnostic Note:
Indicates the state immediately after regeneration control completes, which combusts any PM adhering to the particulate matter sensor electrode.

Status of PM Sensor Rejuvenate
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Status of PM Sensor Rejuvenate Status of PM Sensor Rejuvenate/
Regeneration Not Active or Regeneration Active
- - -
Diagnostic Note:
Indicates the state of regeneration control, which combusts any PM adhering to the particulate matter sensor electrode.

Status of PM Sensor Temperature
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Status of PM Sensor Temperature Status of PM Sensor Temperature/
No Error Detected or Error Detected
- - -
Diagnostic Note:
Outputs P24C6 when a malfunction occurs (tool display).

Status of PM Sensor IDE (- Side)
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Status of PM Sensor IDE (- Side) Status of PM Sensor IDE (- Side)/
No Error Detected or Error Detected
- - -
Diagnostic Note:
Outputs P24B1 when a malfunction occurs (tool display).

Status of PM Sensor Measurement
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Status of PM Sensor Measurement Status of PM Sensor Measurement/
Measurement Not Active or Measurement Active
- - -
Diagnostic Note:
Indicates whether the particulate matter sensor is measuring PM.

Status of PM Sensor SCU Output Data
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Status of PM Sensor SCU Output Data Status of PM Sensor SCU Output Data/
Sensor Values or Initial Values
- - -
Diagnostic Note:
Indicates whether the output of the sensor control unit of the particulate matter sensor is controlled.

Status of PM Sensor SCU Operation
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Status of PM Sensor SCU Operation Status of PM Sensor SCU Operation/
SCU Not Ready or SCU Ready
- - -
Diagnostic Note:
Indicates whether the sensor control unit of the particulate matter sensor is operating.

PM Sensor Clogged Diagnosis
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
PM Sensor Clogged Diagnosis PM Sensor Clogged Diagnosis/
Conditions Not Given or Conditions Given
- - -
Diagnostic Note:
Indicates whether the cover of the particulate matter sensor can be diagnosed as clogged.

Status of PM Sensor Malfunction
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Status of PM Sensor Malfunction Status of PM Sensor Malfunction/
Not Failure Mode or Failure Mode
- - -
Diagnostic Note:
Indicates whether the particulate matter sensor has detected a DTC.

Status of PM Sensor Measurement Request
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Status of PM Sensor Measurement Request Status of PM Sensor Measurement Request/
ON or OFF
- - -
Diagnostic Note:
Indicates whether the ECM is requesting that the particulate matter sensor performs measurements.

Status of PM Sensor Self Diagnosis Clear
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Status of PM Sensor Self Diagnosis Clear Status of PM Sensor Self Diagnosis Clear/
ON or OFF
- - -
Diagnostic Note:
Indicates the initialization status when the engine switch is turned from off to on (IG).

Status of PM Sensor Carrying Request
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Status of PM Sensor Carrying Request Status of PM Sensor Carrying Request/
ON or OFF
- - -
Diagnostic Note:
Indicates whether the particulate matter sensor is requesting power for measuring.

Status of PM Sensor Engine Operation
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Status of PM Sensor Engine Operation Status of PM Sensor Engine Operation/
ON or OFF
- - -
Diagnostic Note:
Indicates whether the particulate matter sensor has judged that the engine is operating.

Status of PM Sensor Heater ON Malfunction
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Status of PM Sensor Heater ON Malfunction Status of PM Sensor IDE Diagnosis (+ Side)/
ON or OFF
- - -
Diagnostic Note:
·

Indicates the presence of a sensor heater ON malfunction in the particular matter sensor.

·

When ON, P24B3 is output.



Status of PM Sensor Heater ON Diagnosis
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Status of PM Sensor Heater ON Diagnosis Status of PM Sensor Heater ON Diagnosis/
Diagnosis Not Tested or Diagnosis Tested
- - -
Diagnostic Note:
Indicates the sensor heater ON malfunction diagnosis procedure condition of the particulate matter sensor.

Status of PM Sensor Heater OFF Malfunction
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Status of PM Sensor Heater OFF Malfunction Status of PM Sensor Heater OFF Malfunction/
ON or OFF
- - -
Diagnostic Note:
·

Indicates the presence of a sensor heater OFF malfunction in the particular matter sensor.

·

When ON, P24B3 is output.



Status of NOx Reduction Efficiency
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Status of NOx Reduction Efficiency Status of NOx Reduction Efficiency/
Normal, Caution, Warning or Danger
- - -
Diagnostic Note:
·

Normal:

SCR system is normal.

·

NOTICE:

Malfunction detected in SCR system (No calculated mileage warning displayed).

·

CAUTION:

Malfunction detected in SCR system.

Visit your dealer for repairs within 800 km.

·

DANGER:

A distance of 800 km or more is travelled after malfunction detection.

Engine restart prohibited after engine is stopped.



Status of Fr-NOx Sensor Lambda Detection Unit
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Status of Fr-NOx Sensor Lambda Detection Unit Status of Fr-NOx Sensor Lambda Detection Unit/
Not Detected, Normal, Abnormal(Open) or Unknown
- - -
Diagnostic Note:
·

Indicates whether an open has occurred in the No. 1 nitrogen oxides sensor lambda function part.

·

Outputs P2200 when a malfunction occurs (tool display).



Status of Fr-NOx Sensor NOx Detection Unit
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Status of Fr-NOx Sensor NOx Detection Unit Status of Fr-NOx Sensor NOx Detection Unit/
Not Detected, Normal, Abnormal(Open) or Unknown
- - -
Diagnostic Note:
·

Indicates whether an open has occurred in the No. 1 nitrogen oxides sensor NOx function part.

·

Outputs P2200 when a malfunction occurs (tool display).



Status of Fr-NOx Sensor
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Status of Fr-NOx Sensor Status of Fr-NOx Sensor/
Not Detected, Normal, Abnormal(GND Short), Abnormal(BATT Short) or Abnormal(Open)
- - -
Diagnostic Note:
·

Indicates whether an open has occurred in the No. 1 nitrogen oxides sensor NOx output line.

·

Outputs P2200 when a malfunction occurs (tool display).



Status of Fr-NOx Sensor Heater
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Status of Fr-NOx Sensor Heater Status of Fr-NOx Sensor Heater/
Not Detected, Normal, Abnormal(GND Short), Abnormal(BATT Short) or Abnormal(Open)
- - -
Diagnostic Note:
·

Indicates whether an open has occurred in the sensor heater of the No. 1 nitrogen oxides sensor.

·

Outputs P220E when a malfunction occurs (tool display).



Fr-NOx Sensor NOx Active Status (SCU)
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Fr-NOx Sensor NOx Active Status (SCU) Fr-NOx Sensor NOx Active Status (SCU)/
Unused, OFF or ON
- - -
Diagnostic Note:
Indicates whether the No. 1 nitrogen oxides sensor NOx function part is active.

Fr-NOx Sensor A/F Active Status (SCU)
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Fr-NOx Sensor A/F Active Status (SCU) Fr-NOx Sensor A/F Active Status (SCU)/
Unused, OFF or ON
- - -
Diagnostic Note:
Indicates whether the No. 1 nitrogen oxides sensor A/F function part is active.

Fr-NOx Sensor Status Information
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Fr-NOx Sensor Status Information Fr-NOx Sensor Status Information/
Control, Standby or OBD
- - -
Diagnostic Note:
Indicates whether the No. 1 nitrogen oxides sensor communication state is preparing or performing control.

Status of Fr-NOx Sensor Power Supply Voltage
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Status of Fr-NOx Sensor Power Supply Voltage Status of Fr-NOx Sensor Power Supply Voltage/
Not Detected, Normal or Abnormal
- - -
Diagnostic Note:
Indicates the power supply voltage being supplied to the No. 1 nitrogen oxides sensor.

Status of NOx Sensor Lambda Detection Unit
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Status of NOx Sensor Lambda Detection Unit Status of NOx Sensor Lambda Detection Unit/
Not Detected, Normal, Abnormal(Open) or Unknown
- - -
Diagnostic Note:
·

Indicates whether an open has occurred in the No. 2 nitrogen oxides sensor lambda function part.

·

Outputs P229E when a malfunction occurs (tool display).



Status of NOx Sensor NOx Detection Unit
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Status of NOx Sensor NOx Detection Unit Status of NOx Sensor NOx Detection Unit/
Not Detected, Normal, Abnormal(Open) or Unknown
- - -
Diagnostic Note:
·

Indicates whether an open has occurred in the No. 2 nitrogen oxides sensor NOx function part.

·

Outputs P229E when a malfunction occurs (tool display).



Status of NOx Sensor
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Status of NOx Sensor Status of NOx Sensor/
Not Detected, Normal, Abnormal(GND Short), Abnormal(BATT Short) or Abnormal(Open)
- - -
Diagnostic Note:
·

Indicates whether an open has occurred in the No. 2 nitrogen oxides sensor NOx output line.

·

Outputs P229E when a malfunction occurs (tool display).



Status of NOx Sensor Heater
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Status of NOx Sensor Heater Status of NOx Sensor Heater/
Not Detected, Normal, Abnormal(GND Short), Abnormal(BATT Short) or Abnormal(Open)
- - -
Diagnostic Note:
·

Indicates whether an open has occurred in the sensor heater of the No. 2 nitrogen oxides sensor.

·

Outputs P220F when a malfunction occurs (tool display).



NOx Sensor NOx Active Status (SCU)
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
NOx Sensor NOx Active Status (SCU) NOx Sensor NOx Active Status (SCU)/
Unused, OFF or ON
- - -
Diagnostic Note:
Indicates whether the No. 2 nitrogen oxides sensor NOx function part is active.

NOx Sensor A/F Active Status (SCU)
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
NOx Sensor A/F Active Status (SCU) NOx Sensor A/F Active Status (SCU)/
Unused, OFF or ON
- - -
Diagnostic Note:
Indicates whether the No. 2 nitrogen oxides sensor A/F function part is active.

NOx Sensor Status Information
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
NOx Sensor Status Information NOx Sensor Status Information/
Control, Standby or OBD
- - -
Diagnostic Note:
Indicates whether the No. 2 nitrogen oxides sensor communication state is preparing or performing control.

Status of NOx Sensor Power Supply Voltage
Tester Display Measurement Item/Range Normal Condition Type Cause of Out of Range
Status of NOx Sensor Power Supply Voltage Status of NOx Sensor Power Supply Voltage/
Not Detected, Normal or Abnormal
- - -
Diagnostic Note:
Indicates the power supply voltage being supplied to the No. 2 nitrogen oxides sensor.


ACTIVE TEST


HINT:

Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.


a.

Connect the GTS to the DLC3.


b.

Turn the engine switch to on (IG).


c.

Turn the GTS on.


d.

Enter the following menus: Powertrain / Engine and ECT / Active Test.


e.

Perform the Active Test.

Tester Display Test Part Control Range Diagnostic Note
Activate the VSV for Swirl Control Valve Activate the vacuum switching valve assembly (for swirl control valve) ON/OFF Test is possible when the following conditions are met:
·

Engine switch on (IG).

·

Engine running (warmed up).


Control the A/C Cut Signal Control the A/C cut signal ON/OFF -
Control the ACM Inhibit Activate vacuum switching valve sub-assembly (for engine mounting) ON/OFF -
Connect the TC and TE1 Turn on the TC and TE1 connection ON/OFF -
Control the Electric Cooling Fan Control the electric cooling fan operation ON/OFF Test is possible when the following conditions are met:
·

Engine switch on (IG).

·

Engine is stopped.


Control the EGR Step Position Control the electric EGR control valve assembly 1 to 100% Test is possible when the following conditions are met:
·

Engine switch on (IG).

·

Engine is stopped.


Activate the VN Turbo Cleaning Activate the VN turbo cleaning ON/OFF Perform this test when the following conditions are met:
·

Engine switch is on (IG).

·

Engine running (warmed up).

·

Engine Coolant Temperature 77°C (171°F) or higher


Activate the DPF Rejuvenate (PM) PM forced regeneration Raise temperature of DPF to more than 600°C (1112°F) by adding fuel intermittently using the exhaust fuel addition injector ON/OFF -
Test the Fuel Leak Pressurize the common rail interior and check for fuel leaks Stop/Start
·

Fuel pressure inside common rail pressurized to specified value and engine speed increased to 2000 rpm when ON is selected

·

Above conditions preserved while test is ON


HINT:

If this Active Test is performed when the engine is cold, combustion may become unstable. However, this is not a malfunction. It is only necessary to confirm that the pressure rises to the target pressure and that there are no fuel leaks.


Activate the Pre-stroke Control Valve Activates the pre-stroke control valve Open/Close Test is possible when the following conditions are met:
·

Engine switch on (IG).

·

Engine is stopped.


Activate the EGR Valve Close Activate the electric EGR control valve assembly Close/OFF Confirm that the vehicle is stopped and the engine is idling
Activate the VSV for EGR Cooler Bypass Activate the No. 1 vacuum switching valve assembly (for EGR Bypass Valve) Bypass/OFF/Cooler Test is possible when the following conditions are met:
·

Engine warmed up

·

Engine is idling

·

Shift lever in neutral


If performing the Active Test continuously, it must be finished within 5 minutes.
Test the Turbo Charger Step Motor Activate the turbocharger sub-assembly 0 to 60% Test is possible when the following conditions are met:
·

Engine switch on (IG).

·

Engine is stopped.


Activate the VN Turbo Open Activate the turbocharger Open/OFF Confirm that the engine is running.
Diesel Throttle Target Angle Control the diesel throttle valve 10 to 100% Test is possible when the following conditions are met:
·

Engine switch on (IG).

·

Engine is stopped.


Control the Select Cylinder Fuel Cut Selected cylinder (cylinder #1 to #4) injector assembly fuel cut #1/#2/#3/#4
ON/OFF
Fuel injection is stopped while the test is ON.
·

Confirm that the vehicle is stopped and the engine is idling.

·

If the running condition of the engine does not worsen even though injection of the designated cylinder is stopped, the cylinder can be determined to be malfunctioning.


Check the Cylinder Compression* Check the cylinder compression pressure ON/OFF Fuel injection stops in all cylinders.
Control the Intercooler Water Pump Control the Intercooler Water Pump 30 to 85% Test is possible when the following conditions are met:
·

Engine switch on (IG)

·

Shift lever in neutral or P

·

Engine is stopped


Reductant Injection Valve Activates the urea injection set Open/Close Test is possible when the following conditions are met:
·

Engine switch on (IG)

·

Shift lever in neutral

·

Ambient temperature 0°C or higher


HINT:

This test can be used to confirm the operating noise of the urea injection set.


Reductant Pipe Heater Activates the urea tube with heater assembly ON/OFF Test is possible when the following conditions are met:
·

Engine switch on (IG)

·

Shift lever in neutral

·

Ambient temperature 0°C or higher


HINT:
·

Operation time is 30 seconds

·

Cannot be operated again for 20 seconds



Reductant Tank Heater Activates the urea tank heater ON/OFF Test is possible when the following conditions are met:
·

Engine switch on (IG)

·

Shift lever in neutral

·

Ambient temperature 0°C or higher

·

Urea solution level is at 2 or higher


HINT:
·

Operation time is 30 seconds

·

Cannot be operated again for 20 seconds



Reductant Discharge Activates the reductant discharge ON/OFF Test is possible when the following conditions are met:
·

Engine switch on (IG)

·

Shift lever in neutral

·

Ambient temperature 0°C or higher


Reductant Filling (Pressure Keep) Activates the reductant filling (pressure keep) ON/OFF Test is possible when the following conditions are met:
·

Engine switch on (IG)

·

Shift lever in neutral

·

Ambient temperature 0°C or higher


HINT:
·

After filling Urea solution to the Urea line, raise the pressure of the Urea to 500 kPa.

·

Used by itself:

Check for urea solution leaks by raising the pressure.

·

Used in combination:

Urea injection is possible if "Reductant Injection Valve" is executed after the completion of this operation.



Reductant Pump Check (Backward) Activates the urea pump check ON/OFF Test is possible when the following conditions are met:
·

Engine switch on (IG)

·

Shift lever in neutral

·

Ambient temperature 0°C or higher


HINT:
·

Operate the pump in reverse to check that it can operate.

·

When performing a forced operation of the pump, first be sure to complete "Reductant Pump Check (Backward)" and check that the pump operates normally.



Reductant Purge Activates the reductant purge ON/OFF Test is possible when the following conditions are met:
·

Engine switch on (IG)

·

Shift lever in neutral

·

Ambient temperature 0°C or higher


HINT:

Operate the pump in reverse and open the urea injection valve in order to draw the urea solution back into the pump from the urea line.





HINT:

*: When cranking the engine, the Active Test measures the speed of each cylinder. In this Active Test, the fuel of all cylinders is cut when the engine is cranked for approximately 10 seconds.


At this time, the speed of each cylinder is measured. If the speed of one cylinder is more than the other cylinders, it can be determined that the compression pressure of that cylinder is lower than the other cylinders.

1.

Warm up the engine.

2.

Turn the engine switch off.

3.

Connect the GTS to the DLC3.

4.

Turn the engine switch to on (IG) and turn the GTS on.

5.

Enter the following menus: Powertrain / Engine and ECT / Active Test / Check the Cylinder Compression.

HINT:

If the results are not displayed normally, select the display items from the Data List before performing the Active Test. Enter the following menus: Powertrain / Engine and ECT / Data List / Compression / Engine Speed of Cyl #1, Engine Speed of Cyl #2, Engine Speed of Cyl #3, Engine Speed of Cyl #4 and Av Engine Speed of All Cyl.


6.

While the engine is not running, press the RIGHT or LEFT button to change Check the Cylinder Compression to ON.

HINT:

After performing the above procedure, the "Check the Cylinder Compression" Active Test will start. Fuel injection for all cylinders is prohibited and the engine speed measurement of each cylinder enters standby mode.


7.

Crank the engine for about 10 seconds.

8.

Monitor the engine speed (Engine Speed of Cyl #1 to #4, Av Engine Speed of All Cyl) displayed on the GTS.

HINT:

At first, the GTS display will show the engine speed measurement of each cylinder to be extremely high. After approximately 10 seconds of engine cranking, the engine speed measurement of each cylinder will change to the actual engine speed.


NOTICE:
·

After the "Check the Cylinder Compression" Active Test is turned on, it will automatically turn off after 255 seconds.

·

When the "Check the Cylinder Compression" test is off and the engine is cranked, the engine will start.

·

If the "Check the Cylinder Compression" test needs to be performed after it is turned on and performed once, press "EXIT" to return to the Active Test menu screen. Then perform the "Check the Cylinder Compression" test again.

·

Use a fully-charged battery.




SYSTEM CHECK


a.

Turn the engine switch to on (IG).


b.

Turn the GTS on.


c.

Enter the following menus: Powertrain / Engine and ECT / Utility.

Powertrain > Engine > Utility
Tester Display Diagnostic Note
Pressure Discharge Valve Check*
·

Malfunctions can be determined by checking the fuel pressure when performing a forced operation of the pressure discharge valve.

·

Use when troubleshooting fuel pressure control malfunctions and abnormal combustion noise.


NOx Sensor Check Check the No. 1 nitrogen oxides sensor or No. 2 nitrogen oxides sensor output
Reductant Injection Valve Check Test is possible when the following conditions are met:
·

Engine switch on (IG)

·

Shift lever in neutral

·

Ambient temperature 0°C or higher


HINT:
·

This test is used to perform operations from urea solution refueling up to injection and determine urea injection set malfunctions (stuck open/closed, spray direction).

·

Perform this test according to the troubleshooting procedure.





d.

*: Activate the Pressure Discharge Valve Check

HINT:
·

This is the procedure for troubleshooting fuel pressure control malfunctions and combustion problems.

·

Malfunctions can be determined by checking the fuel pressure when performing a fuel cut and operating the pressure discharge valve with the GTS.

·

During "Pressure Discharge Valve Check", the GTS measures the fuel pressure while the engine is running, after the engine is stopped, and after the pressure discharge valve operates.



i.

Connect the GTS to the DLC3.


ii.

Turn the engine switch on (IG).


iii.
A204072

Turn the GTS on.

NOTICE:

Confirm the following conditions:

·

Engine is idling.

·

Vehicle is stopped.

·

Fuel pressure is not extremely high (below 100 MPa).

·

Fuel pressure is not extremely low (higher than 26 MPa).

·

Fuel pressure sensor is normal.

·

Battery voltage is higher than 8 V.



HINT:

When the common rail pressure is unstable, the fuel pressure may decrease to a level where the test cannot be performed. In this situation, wait until the common rail pressure meets the test condition, and then perform the test.



iv.

Enter the following menus: Powertrain / Engine and ECT / Utility / Pressure Discharge Valve Check.


v.
A266982

Press "Next".


vi.
A266983

Press "Next" again to proceed.


vii.
A267386

Select the check type "Valve Check for Graph".

1.

Press "Next" again to proceed.

2.

Press "Start" again to proceed.

A267385E03
3.469,1.833 3.698,1.417 3.698,1.417 3.802,1.417 false 2.188,1.458 2.406,1.125 2.406,1.125 2.521,1.125 false 3.948,2.188 4.198,1.844 4.198,1.844 4.281,1.844 false 3.865,1.354 4.875,1.656 1.01,0.302 10 true Fuel Pressure 4.354,1.802 6.042,2.125 1.688,0.323 10 true Pressure Discharge Valve 2.406,3.74 2.615,3.917 0.208,0.177 10 false *1 3.802,3.74 4.01,3.917 0.208,0.177 10 false *2 2.583,1.063 3.563,1.354 0.979,0.292 10 true Engine Speed


*1: When "Start" is pressed, the pressure discharge valve check begins.

*2: If "Save" is pressed after the pressure discharge valve check, the data recorded during the valve check can be saved.


viii.
A267386

Select the check type "Close to Open Check" or "Always Closed Check".

HINT:
·

"Close to Open Check" opens the pressure discharge valve after the engine stops.

·

"Always Closed Check" holds the pressure discharge valve closed during the check.



1.

Press "Next".

2.

Perform troubleshooting based on the measurement results.

A266984

HINT:
·

During "Close to Open Check", if there is no large change in fuel pressure when the pressure discharge valve is closed while the engine is running and after the engine is stopped, and if the value is 0 kPa when the pressure discharge valve is open, the system is normal.

·

Perform "Always Closed Check" if the value is not 0 kPa when the pressure discharge valve is open during "Close to Open Check". If the results are the same as during "Close to Open Check", there is a pressure discharge valve operation malfunction.

·

If the fuel temperature is high, perform "Pressure Discharge Valve Check" after the fuel has cooled to the outside air temperature.

·

If a large amount of fuel is leaking, the fuel pressure decreases when the engine is stopped. However, the condition of the pressure discharge valve can still be determined by comparing the measurement results of "Close to Open Check" and "Always Closed Check".


A303297E12
5.365,0.083 6.771,0.281 1.406,0.198 10 false Fuel Press Recorded 0.74,1.438 2.406,1.646 1.667,0.208 10 false Common Rail Pressure 0.75,2.635 2.281,2.833 1.531,0.198 10 false (Close to Open Check) 2.719,1.833 3.167,2.031 0.448,0.198 10 false 0 kPa 0.75,2.49 2.417,2.677 1.667,0.188 10 false Common Rail Pressure 0.76,1.594 2.292,1.792 1.531,0.198 10 false (Always Closed Check) 2.75,3.219 3.198,3.417 0.448,0.198 10 false 0 kPa 0.75,3.667 2.417,4.083 1.667,0.417 10 false Engine Speed 2.75,3.885 3.198,4.083 0.448,0.198 10 false 0 rpm 2.833,4.333 3.281,4.531 0.448,0.198 10 false On 2.833,4.667 3.135,4.865 0.302,0.198 10 false Off 0.5,4.49 2.26,4.74 1.76,0.25 10 false Fuel Cut Operation Signal 0.5,5.219 2.156,5.583 1.656,0.365 10 false Pressure Discharge Valve Operation Prohibition 2.833,5.167 3.135,5.365 0.302,0.198 10 false Off 2.833,5.469 3.281,5.667 0.448,0.198 10 false On 2.396,5.833 3.25,6.073 0.854,0.24 10 false Closed (on) 2.833,6.135 3.135,6.333 0.302,0.198 10 false Off 2.49,6.5 3.344,6.74 0.854,0.24 10 false Open (on) 2.427,6.802 3.281,7.042 0.854,0.24 10 false Closed (on) 2.833,7.083 3.135,7.281 0.302,0.198 10 false Off 2.875,7.438 5.542,7.688 2.667,0.25 10 false Pressure Discharge Valve Operation Start 0.115,5.917 2.385,6.406 2.271,0.49 10 false Pressure Discharge Valve Operation (Always Closed Check) 0.115,6.635 2.365,7.125 2.25,0.49 10 false Pressure Discharge Valve Operation (Close to Open Check)