Home › Engine / Hybrid System › 1GD-FTV (INTAKE / EXHAUST) › RADIATOR (w/ Urea SCR System) › from 2018.06
RM27T0E _51 Engine / Hybrid System _053680 1GD-FTV INTAKE / EXHAUST _0358839 RADIATOR(w/ Urea SCR System) G

1GD-FTV INTAKE / EXHAUST  RADIATOR(w/ Urea SCR System)  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 1.INSPECT RESERVOIR CAP

a.

Measure the valve opening pressure.

i.
A287226C13
0.677,1.948 0.844,1.948 0.844,1.948 1.229,1.708 false 2.844,1.802 2.656,1.802 2.656,1.802 2.052,1.458 true 0.427,1.854 0.667,2.021 0.24,0.167 10 false *a 2.906,1.729 3.135,1.906 0.229,0.177 10 false *b
*a O-ring
*b Rubber Packing


If there are water stains or foreign matter on the O-ring, clean it with water and finger scouring.

NOTICE:

Always perform procedure by hand so as not to damage the O-ring.



ii.

Check that the O-ring is not deformed, cracked or swollen.


iii.

Apply engine coolant to the O-ring and rubber packing before using a radiator cap tester.


iv.
B008802C21
0.479,0.563 0.667,0.198 0.667,0.198 0.833,0.198 false 1.021,0.708 1.365,0.198 1.365,0.198 1.531,0.198 false 0.885,0.083 1.198,0.24 0.313,0.156 10 false *1 1.594,0.083 1.906,0.24 0.313,0.156 10 false *a 0.531,1.052 0.844,1.208 0.313,0.156 10 false *b
*1 Reserve Tank Cap
*a Radiator Cap Tester
*b 30° or more


When using the radiator cap tester, tilt it more than 30° degrees.


v.

Pump the radiator cap tester several times and check the maximum pressure*.

Pump speed:

1 pump per second


*: Even if the cap cannot maintain the maximum pressure, it is not a defect.

Standard Judgment Criterion:
Item Specified Condition
Standard value (for brand-new cap) 93 to 123 kPa (1.0 to 1.3 kgf/cm2, 13.5 to 18 psi)
Minimum standard value (for used cap) 79 kPa (0.8 kgf/cm2, 11.4 psi)


If the maximum pressure is less than the minimum standard value, replace the reservoir cap (for Intercooler).