894A0
1.INSTALL PARTICULATE MATTER SENSOR
Install the particulate matter sensor with the 2 nuts to the exhaust sensor clamp bracket, and attach the 2 clamps.
| *a | Torque Wrench Fulcrum Length |
Using SST, install the particulate matter sensor.
Replace with a new part if it is dropped or if it receives a strong impact.
Calculate the torque wrench reading when changing the fulcrum length of the torque wrench.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
When using SST (fulcrum length of 40 mm (1.58 in.)) + torque wrench (fulcrum length of 255 mm (10.0 in.)): 43.2 N*m (441 kgf*cm, 32 ft.*lbf)
Install the controller portion (exhaust sensor clamp bracket) with the 2 bolts, and then attach the connector and 2 clamps.
Complete the installation so that there is no tension or slack in the harness of the particulate matter sensor, and there is no interference.
89439K
2.INSTALL NO. 3 SENSOR BRACKET