89424D
1.INSPECT INTAKE AIR TEMPERATURE SENSOR
w/o Urea SCR System:
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 2.21 to 2.65 kΩ |
| 60°C (140°F) | 0.54 to 0.62 kΩ |
If the result is not as specified, replace the intake air temperature sensor.
w/ Urea SCR System:
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 25 °C (77 °F) | 15.94 to 18.53 kΩ |
| 50 °C (122 °F) | 9.01 to 10.25 kΩ |
If the result is not as specified, replace the intake air temperature sensor.