Home › General › SPECIFICATIONS › 1GD-FTV ENGINE CONTROL › from 2018.06
RM27T0E _V1 General _053654 SPECIFICATIONS _0260388 1GD-FTV ENGINE CONTROL F

SPECIFICATIONS  1GD-FTV ENGINE CONTROL  SERVICE DATA  


VACUUM SWITCHING VALVE (for Engine Mounting)
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 37 to 44 Ω

MASS AIR FLOW METER
Tester Connection Condition Specified Condition
4 (THA) - 2 (E2G) -20°C (-4°F) 13.6 to 18.4 kΩ
20°C (68°F) 2.21 to 2.69 kΩ
60°C (140°F) 0.49 to 0.67 kΩ

ENGINE COOLANT TEMPERATURE SENSOR
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 2.32 to 2.59 kΩ
80°C (176°F) 0.310 to 0.326 kΩ

ENGINE COOLANT TEMPERATURE SENSOR (for Intercooler)
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 2.32 to 2.59 kΩ
80°C (176°F) 0.310 to 0.326 kΩ

INTAKE AIR TEMPERATURE SENSOR (w/o Urea SCR System)
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 2.21 to 2.65 kΩ
60°C (140°F) 0.54 to 0.62 kΩ

INTAKE AIR TEMPERATURE SENSOR (w/ Urea SCR System)
Tester Connection Condition Specified Condition
1 - 2 25 °C (77 °F) 15.94 to 18.53 kΩ
50 °C (122 °F) 9.01 to 10.25 kΩ

MANIFOLD ABSOLUTE PRESSURE SENSOR
Tester Connection Switch Condition Specified Condition
3 (VC) - 1 (E) Ignition switch ON 4.75 to 5.25 V

AIR FUEL RATIO SENSOR
Tester Connection Condition Specified Condition
1 (HA1A) - 2 (+B) 20°C (68°F) 1.6 to 3.2 Ω
3(A1A+) - 4(A1A-) Always 10 kΩ or higher