88625P
1.INSPECT COOLER THERMISTOR (AMBIENT TEMPERATURE SENSOR)
| *a | Component without harness connected
(Cooler Thermistor (Ambient Temperature Sensor)) |
| *b | Sensor Area |
| *c | Resistance (kΩ) |
| *d | Temperature (°C (°F)) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 10°C (50°F) | 3.00 to 3.73 kΩ |
| 15°C (59°F) | 2.45 to 2.88 kΩ | |
| 20°C (68°F) | 1.95 to 2.30 kΩ | |
| 25°C (77°F) | 1.60 to 1.80 kΩ | |
| 30°C (86°F) | 1.28 to 1.47 kΩ | |
| 35°C (95°F) | 1.00 to 1.22 kΩ | |
| 40°C (104°F) | 0.80 to 1.00 kΩ | |
| 45°C (113°F) | 0.65 to 0.85 kΩ | |
| 50°C (122°F) | 0.50 to 0.70 kΩ | |
| 55°C (131°F) | 0.44 to 0.60 kΩ | |
| 60°C (140°F) | 0.36 to 0.50 kΩ |
Touching the sensor even slightly may change the resistance value. Be sure to hold the connector of the sensor.
When measuring the resistance, the sensor temperature must be the same as the ambient temperature.
As the temperature increases, the resistance decreases (refer to the graph).
If the result is not as specified, replace the cooler thermistor (ambient temperature sensor).