Home › Audio / Visual / Telematics › TELEMATICS › MAYDAY SWITCH › from 2020.08
RM27T0E _56 Audio / Visual / Telematics _056796 TELEMATICS _0280989 MAYDAY SWITCH G

TELEMATICS  MAYDAY SWITCH  INSPECTION  


PROCEDURE

Hide 81260A 2.INSPECT MAP LIGHT ASSEMBLY

a.

Check the resistance.

i.
E348946C11
2.333,1.833 2.625,1.219 true 1.906,2.115 1.583,2.74 true 1.458,2.76 2.073,2.958 0.615,0.198 10 false SIG1 2.656,1.115 3.271,1.313 0.615,0.198 10 false GND3 0.052,0.052 0.365,0.25 0.313,0.198 10 false *a
*a Component without harness connected
(Map Light Assembly)


Measure the resistance according to the value(s) in the table below.

Resistance:
Tester Connection Condition Specified Condition
W7-20 (SIG1) - W7-3 (GND3) Mayday switch not pressed 410 to 414 Ω
W7-20 (SIG1) - W7-3 (GND3) Mayday switch pressed 81 to 83 Ω




b.

Check the operation (indicator).

i.
E455347C01
1.771,0.625 1.771,0.302 1.771,0.302 1.406,0.302 false 1.563,1.688 1.833,2.354 true 2.177,3.063 1.938,2.594 true 1.229,0.24 1.542,0.438 0.313,0.198 10 false *b 0.073,0.063 0.385,0.26 0.313,0.198 10 false *a 1.365,1.51 1.74,1.677 0.375,0.167 10 false GND 2.094,3.115 2.708,3.313 0.615,0.198 10 false IND1
*a Component without harness connected
(Map Light Assembly)
*b Two 1.5 V dry cell batteries


Check that each indicator illuminates when 2 dry cell batteries are connected to the map light assembly connector terminals as shown in the illustration.

NOTICE:

Do not apply more than 3 V.


OK:
Tester Connection Condition Specified Condition
W7-19 (IND1) - W7-5 (GND) Positive (+) dry cell battery - Negative (-) dry cell battery HELP RED indicator illuminates



ii.
E455348C01
1.771,0.625 1.771,0.302 1.771,0.302 1.406,0.302 false 1.583,1.802 1.885,2.354 true 2.031,2.635 2.031,3.083 true 1.229,0.24 1.542,0.438 0.313,0.198 10 false *b 0.073,0.063 0.385,0.26 0.313,0.198 10 false *a 1.406,1.573 1.781,1.781 0.375,0.208 10 false GND 1.927,3.135 2.542,3.333 0.615,0.198 10 false IND2
*a Component without harness connected
(Map Light Assembly)
*b Two 1.5 V dry cell batteries


Check that each indicator illuminates when 2 dry cell batteries are connected to the map light assembly connector terminals as shown in the illustration.

NOTICE:

Do not apply more than 3 V.


OK:
Tester Connection Condition Specified Condition
W7-18 (IND2) - W7-5 (GND) Positive (+) dry cell battery - Negative (-) dry cell battery HELP GREEN indicator illuminates




c.
E348946C10
1.615,1.219 2,1.833 true 2.313,2.115 1.917,2.74 true 1.344,0.979 1.802,1.177 0.458,0.198 10 false GND 1.781,2.771 2.24,2.969 0.458,0.198 10 false RRID 0.063,0.052 0.375,0.25 0.313,0.198 10 false *a
*a Component without harness connected
(Map Light Assembly)


Check that the HELP indicator illuminates when the battery is connected to the map light assembly connector terminals as shown in the illustration.

OK:
Tester Connection Condition Specified Condition
W7-17 (RRID) - W7-5 (GND) Positive (+) battery terminal - Negative (-) battery terminal HELP indicator illuminates