Home › Vehicle Interior › HEATING / AIR CONDITIONING › REFRIGERANT (for HFC-134a(R134a)) › from 2020.08
RM27T0E _58 Vehicle Interior _053739 HEATING / AIR CONDITIONING _0277057 REFRIGERANT(for HFC-134a(R134a)) G

HEATING / AIR CONDITIONING  REFRIGERANT(for HFC-134a(R134a))  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 1.INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET

a.

This method uses a manifold gauge set to locate problem areas. Read the manifold gauge pressure when these conditions are established.

Test conditions:

·

Temperature at the air inlet with the switch set at RECIRC is 30 to 35°C (86 to 95°F).

·

Engine is running at 1500 rpm.

·

All doors are fully open.

·

Blower speed control switch is at HI.

·

A/C switch is on.


Gauge readings (Reference).

E268295C05
2.99,2.417 3.156,2.417 3.156,2.417 3.156,2.729 false 3.333,2.896 3.5,2.896 3.5,2.896 3.5,3.063 false 3.469,3.396 3.635,3.396 3.635,3.396 3.635,3.229 false 3.729,3.802 3.896,3.802 3.896,3.802 3.896,3.635 false 3.583,1.667 4.167,2.063 false 4.75,2.521 5.333,2.917 false 0.229,3.135 2.219,3.333 1.99,0.198 10 false 200 (2.0, 29) 0.229,2.448 2.219,2.646 1.99,0.198 10 false 300 (3.1, 44) 0.229,1.75 2.219,1.948 1.99,0.198 10 false 400 (4.1, 58) 0.229,1.073 2.219,1.271 1.99,0.198 10 false 500 (5.1, 73) 1.375,4.24 3.365,4.438 1.99,0.198 10 false 500 (5.1, 73) 2.552,4.24 4.542,4.438 1.99,0.198 10 false 1000 (10.2, 145) 3.833,4.24 5.823,4.438 1.99,0.198 10 false 1500 (15.3, 218) 5.104,4.24 7.094,4.438 1.99,0.198 10 false 2000 (20.4, 290) 1.229,3.552 3.219,3.75 1.99,0.198 10 false 140 (1.4, 20) 1.302,3.146 3.292,3.344 1.99,0.198 10 false 200 (2.0, 29) 1.229,2.969 3.219,3.167 1.99,0.198 10 false 220 (2.2, 32) 1.24,2.635 3.229,2.833 1.99,0.198 10 false 270 (2.8, 39) 1.958,2.323 3.948,2.521 1.99,0.198 10 false 1060 (10.8, 154) 2.313,2.802 4.302,3 1.99,0.198 10 false 1200 (12.2, 174) 2.448,3.313 4.438,3.51 1.99,0.198 10 false 1250 (12.7, 181) 2.708,3.708 4.698,3.906 1.99,0.198 10 false 1320 (13.5, 191) 1.021,0.573 1.333,0.771 0.313,0.198 10 false *a 6.292,4.094 6.604,4.292 0.313,0.198 10 false *b 3.427,1.542 3.74,1.74 0.313,0.198 10 false *c 5.365,2.875 5.677,3.073 0.313,0.198 10 false *d
*a Pressure on Low-Pressure Side kPa (kgf/cm2, psi) *b Pressure on High-Pressure Side kPa (kgf/cm2, psi)
*c Blower High Zone *d Blower Low Zone


i.
E050573

Normally functioning refrigeration system

Gauge Reading:
Pressure Side Refrigerant Volume
Low 147 to 245 kPa (1.5 to 2.5 kgf/cm2, 21 to 36 psi)
High 1372 to 1569 kPa (14 to 16 kgf/cm2, 199 to 228 psi)



ii.

The A/C system periodically changes between normal and improper function due to moisture in the refrigerant system.

I022117

Symptoms Probable Cause Diagnosis Corrective Actions
During operation, pressure on low pressure side cycles between normal and vacuum Moisture in refrigeration system freezes at expansion valve orifice, causing temporary stop of cycle. However, when melted, normal state is restored. - Dryer is overly saturated
- Moisture in refrigeration system freezes at expansion valve orifice and blocks refrigerant circulation
1. Replace cooler dryer
2. Remove moisture from cycle by repeatedly evacuating air
3. Supply appropriate volume of new refrigerant


iii.

The A/C system does not function effectively due to insufficient refrigerant.

I022118

Symptoms Probable Cause Diagnosis Corrective Actions
- Pressure low on both low and high pressure sides
- Cooling performance insufficient
Gas leakage from refrigeration system - Insufficient refrigerant
- Refrigerant leakage
1. Check for gas leakage and repair if necessary
2. Supply appropriate volume of new refrigerant
3. If indicated pressure value close to 0 when connected to gauge, create vacuum after inspecting and repairing the location of leakage


iv.

The A/C system does not function effectively due to poor circulation of the refrigerant.

I022119

Symptoms Probable Cause Diagnosis Corrective Actions
- Pressure low on both low and high pressure sides
- Frost exists on piping from condenser to A/C unit
Refrigerant flow obstructed by dirt in condenser Condenser clogged Replace condenser


v.

The A/C system does not function or functions intermittently because the refrigerant does not circulate.

I022120

Symptoms Probable Cause Diagnosis Corrective Actions
- Vacuum indicated on low pressure side, and extremely low pressure indicated on high pressure side
- Frost or condensation seen on piping on both sides of condenser or expansion valve
- Refrigerant flow obstructed by moisture or dirt in refrigeration system
- Refrigerant flow obstructed by gas leakage from expansion valve
Refrigerant does not circulate 1. Check expansion valve refrigerant
2. Clean expansion valve by blowing air
3. Replace condenser
4. Evacuate air and charge appropriate volume of new refrigerant
5. For gas leakage from expansion valve, replace expansion valve


vi.

The A/C system does not function effectively due to overcharged refrigerant or insufficient cooling of the condenser.

I022121

Symptoms Probable Cause Diagnosis Corrective Actions
Pressure extremely high on both low and high-pressure sides - Excessive refrigerant
- Cooling performance of condenser insufficient
- Condenser is dirty
- Condenser fan motor is malfunctioning
- Excessive refrigerant
1. Clean condenser
2. Check condenser fan motor operation
3. If 1 and 2 normal, check the amount of refrigerant and supply appropriate volume of refrigerant


vii.

The A/C system does not function due to air in the refrigeration system.

CAUTION:

The low-pressure piping may be very hot and cause serious burns.


I022122E34
7.073,1.729 7.104,1.76 0.031,0.031 4.76,0.375 6.698,1.24 1.938,0.865 10 false HINT: These gauge indications occur when the refrigeration system opens and the refrigerant is charged without vacuum purging

Symptoms Probable Cause Diagnosis Corrective Actions
- Pressure extremely high on both low and high-pressure sides
- Low-pressure piping is too hot to touch
Air in refrigeration system - Air in refrigeration system
- Vacuum purging insufficient
1. Check if compressor oil is dirty or insufficient
2. Evacuate air and charge new refrigerant


viii.

The A/C system does not function effectively due to an expansion valve malfunction.

I022123

Symptoms Probable Cause Diagnosis Corrective Actions
- Pressure extremely high on both low and high-pressure sides
- Frost or condensation on piping on low-pressure side
Problem with expansion valve - Excessive refrigerant in low pressure piping
- Expansion valve too wide open
Replace expansion valve


ix.

The A/C system does not function due to a defective compressor.

I022124

Symptoms Probable Cause Diagnosis Corrective Actions
- Pressure extremely high on both low and high-pressure sides
- Pressure extremely low on high pressure side
Internal leakage in compressor - Compression failure
- Leakage from damaged valve or broken sliding parts
Repair or replace compressor