While the engine is being cranked, a starter operation request signal is sent to terminal STA of the ECM.
If there is an open in the STA circuit of the ECM, stop and start control will be prohibited after the third time the engine is started by stop and start control.
Stop and start control will be prohibited until the engine switch is turned off.
The MIL will not illuminate.
If there is an open in the STA circuit of the ECM, the engine can still be started using the engine switch, as the ECM also receives the starter operation request signal from the engine stop and start ECU via CAN communication. (Stop and start control is prohibited as the reliability of the signal sent via CAN communication cannot be assured while the voltage drops during operation of the starter assembly.)
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Enter the following menus: Powertrain / Engine / Data List / Starter SW.
Read the values displayed on the GTS when the engine switch is on (IG) and on (START).
| Tester Display | Condition | Normal Condition |
|---|---|---|
| Starter SW | Engine switch on (IG) | OFF |
| Engine switch on (START) | ON |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the engine stop and start ECU connector.
Disconnect the ECM connector.
Remove the ST NO. 2 relay from the engine room relay block and junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G184-22 (STA) - ST NO. 2 relay terminal 2 | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG