Home › Engine / Hybrid System › 1GD-FTV (STARTING) › RELAY › from 2020.08
RM27T0E _51 Engine / Hybrid System _053695 1GD-FTV STARTING _0260746 RELAY G

1GD-FTV STARTING  RELAY  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 28300 1.INSPECT NO. 1 STARTER RELAY ASSEMBLY (ST NO. 1)

a.
A301376N01
2.333,0.792 2.635,0.51 false 2.052,1.75 2.344,1.438 false 1.656,1.115 2.01,1.115 false 2.656,1.115 3.01,1.115 false 0.281,1.313 0.438,1.51 0.156,0.198 10 1 1.271,1.323 1.427,1.521 0.156,0.198 10 2 0.302,0.771 0.458,0.969 0.156,0.198 10 3 1.271,0.781 1.427,0.979 0.156,0.198 10 5 2.677,0.427 2.833,0.625 0.156,0.198 10 1 1.938,1.708 2.094,1.906 0.156,0.198 10 2 1.51,1.031 1.667,1.229 0.156,0.198 10 3 3.063,1.031 3.219,1.229 0.156,0.198 10 5

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
Battery voltage applied to terminals 1 and 2 Below 1 Ω


If the result is not as specified, replace the No. 1 starter relay assembly.


Hide 28300F 2.INSPECT NO. 2 STARTER RELAY ASSEMBLY (ST NO. 2)

a.
B060778N28
2.031,0.729 1.677,0.333 true 2.625,0.729 2.99,0.365 true 2.354,1.104 3,0.948 true 2.354,1.604 3,1.479 true 1.552,0.25 1.698,0.417 0.146,0.167 10 false 1 3.021,0.271 3.167,0.427 0.146,0.156 10 false 2 3.031,0.865 3.219,1.021 0.188,0.156 10 false 5 3.042,1.385 3.167,1.542 0.125,0.156 10 false 3 1.167,0.76 1.333,0.938 0.167,0.177 10 false 5 1.167,1.292 1.313,1.458 0.146,0.167 10 false 2 0.25,0.74 0.396,0.906 0.146,0.167 10 false 3 0.24,1.271 0.354,1.438 0.115,0.167 10 false 1

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
Battery voltage applied to terminals 1 and 2 Below 1 Ω


If the result is not as specified, replace the No. 2 starter relay assembly.


Hide 28610 3.INSPECT GLOW RELAY (GLOW)

a.
A092673E94
0.198,1.313 0.396,1.531 0.198,0.219 10 true 1 0.229,0.771 0.406,0.958 0.177,0.188 10 true 5 1.271,0.781 1.469,0.979 0.198,0.198 10 true 3 1.281,1.323 1.438,1.521 0.156,0.198 10 true 2 1.427,1.031 1.604,1.229 0.177,0.198 10 true 3 2.698,0.344 2.896,0.563 0.198,0.219 10 true 1 3.146,1.031 3.323,1.219 0.177,0.188 10 true 5 1.979,1.75 2.135,1.948 0.156,0.198 10 true 2

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
Battery voltage applied to terminals 1 and 2 Below 1 Ω


If the result is not as specified, replace the glow relay.